300/500V PVC insulated non-sheathed single core cable is designed for fixed wiring installations.
It is suitable for building wiring, conduit systems, trunking, switchgear, control panels and protected electrical installations.
The cable is widely used in domestic, commercial and industrial low voltage applications.
It should be installed in conduit, trunking or other protected wiring systems where mechanical protection is provided.
The cable should be selected according to voltage rating, conductor size, installation method and project specification.
Basic design to BS EN 50525-2-31(formerly BS 6004:2000)
| Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2 |
300/500V
| Conductor | H05V-U | Class 1 solid copper conductor to BS EN 60228. |
| H05V-R | Class 2 stranded copper conductor to BS EN 60228. | |
| H05V-K | Class 5 stranded copper conductor to BS EN 60228. | |
| Insulation | PVC Type TI 3 according to BS EN 50363-3 | |
Black, Blue, Brown, Grey, Orange, Pink, Red, Turquoise, Violet, White, Green and Yellow. Bicolours of any combination of the above mono-colours are permitted.
| Maximum temperature range during operation (PVC) | 90°C | |
| Maximum short circuit temperature (5 Seconds) | 160°C | |
| Minimum bending radius | Up to 8mm² | 4 x overall diameter |
| 8mm² to 12mm² | 5 x overall diameter | |
| Above 12mm² | 6 x overall diameter | |
| Conductor | FLP300-V2-U/R/K | |||
|---|---|---|---|---|
| No. of Cores x Cross Section | Class of Conductor | Nominal Insulation Thickness | Maximum Overall Diameter | Approx. Weight |
| No.xmm² | mm | mm | kg/km | |
| 1x0.50 | 1 | 0.6 | 2.3 | 8 |
| 1x0.75 | 1 | 0.6 | 2.5 | 11 |
| 1x1.0 | 1 | 0.6 | 2.7 | 14 |
| 1x0.50 | 2 | 0.6 | 2.4 | 9 |
| 1x0.75 | 2 | 0.6 | 2.6 | 12 |
| 1x1.0 | 2 | 0.6 | 2.8 | 14 |
| 1x0.50 | 5 | 0.6 | 2.5 | 8 |
| 1x0.75 | 5 | 0.6 | 2.7 | 11 |
| 1x1.0 | 5 | 0.6 | 2.8 | 13 |
| Conductor cross-sectional area | PVC insulated types (HD 21) | |
|---|---|---|
| single-phase a.c. | three-phase a.c. | |
| mm² | A | A |
| 0.50 | 3 | 3 |
| 0.75 | 6 | 6 |
| 1.0 | 10 | 10 |
Note: These values apply to the majority of cases. Further information should be sought in unusual cases eg.: (i) When high ambient temperatures are involved, ie. above 30°C (ii) Where long lengths are used (iii) Where ventilation is restricted (iv) Where the cords are used for other purposes, ego internal wiring of apparatus. | ||
| Nominal Cross Section Area | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, three-phase a.c. | |||||
|---|---|---|---|---|---|---|---|---|
| Ref. Methods A and B (enclosed in conduit or trunking) | Ref. Methods C, F & G (clipped direct, on trays or in free air) | Ref. Methods A & B (enclosed in conduit or trunking | Ref. Methods C, F & G (clipped direct, on trays or in free air) | |||||
| Cables touching | Cables spaced* | Cables touching, Trefoil | Cables touching, Flat | Cables spaced*, Flat | ||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| mm² | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m |
| 0.50 | 93 | 93 | 93 | 93 | 80 | 80 | 80 | 80 |
| 0.75 | 62 | 62 | 62 | 62 | 54 | 54 | 54 | 54 |
| 1.0 | 46 | 46 | 46 | 46 | 40 | 40 | 40 | 40 |
KEY FEATURES
- Manufactured according to BS EN 50525-2-31 requirements
- 300/500V voltage rating
- PVC insulated single core cable
- Non-sheathed cable construction
- Suitable for fixed wiring installation
- Suitable for conduit and trunking systems
- Suitable for switchgear and control panels
- Suitable for protected low voltage electrical installations
- Copper conductor construction
- Commonly used as building wire and panel wiring cable
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Conductor size
- Conductor class
- Cable length
- Insulation colour
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
300/500V PVC insulated non-sheathed single core cable is commonly selected for fixed wiring and protected low voltage installations.
It should be installed where mechanical protection is provided by conduit, trunking, panels or enclosures.
RELATED CABLE TYPES
- 300/500V PVC insulated PVC sheathed single core cable
- 300/500V PVC insulated PVC sheathed multi-core cable
- 2491X cable
- 2491X HR cable
- 6491X cable
- 6491X HR cable
- 6181Y cable
- 6181X cable
- BS6004 PVC cable
- BS7211 LSZH cable
FAQ
What is this 300/500V PVC insulated non-sheathed cable used for?
This cable is used for fixed wiring and protected low voltage electrical installations.
It is suitable for conduit systems, trunking, switchgear, control panels and building wiring.
Is this cable sheathed?
No. This is a non-sheathed single core cable.
It should be installed in conduit, trunking, panels or protected enclosures.
What standard does this cable follow?
This cable is designed according to BS EN 50525-2-31 requirements.
Can this cable be used in control panels?
Yes. This cable can be used for control panels, switchgear and equipment wiring where protected installation is provided.
Can BURYCABLE supply 300/500V PVC insulated non-sheathed cable?
Yes. BURYCABLE can supply 300/500V PVC insulated non-sheathed single core cables according to project size, colour, length and packing requirements.