600/1000V single core Mica + XLPE
insulated LSZH sheathed fire resistant cable
is designed for critical power circuits.
It is suitable for power stations,
metro systems, tunnels, airports,
petrochemical plants, hospitals,
hotels and high-rise buildings.
The mica tape layer helps maintain
circuit integrity during fire conditions.
The XLPE insulation provides reliable
electrical performance and thermal stability.
The LSZH sheath helps reduce smoke emission
and corrosive gas release in the event of fire.
This cable is commonly selected for projects
where fire safety, flame retardance
and low smoke performance are required.
As a single core unarmoured cable,
it does not provide metallic armour protection.
It is suitable for cable trays,
cable ducts, risers, panels
and protected fixed installation routes.
Where additional mechanical protection
is required, the cable should be installed
with suitable protection.
The cable should be selected according to
voltage rating, conductor size,
fire performance, installation method
and project specification.
Basic design adapted from BS 8573:2012
| Circuit Integrity | IEC 60331-21; BS 6387; BS 8491 |
| Flame Retardance (Single vertical wire or cable test) | IEC 60332-1-2; EN 60332-1-2 |
| Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) | IEC 60332-3-24; EN 60332-3-24 |
| Halogen free | IEC 60754-1; EN 50267-2-1 |
| No Corrosive Gas Emission | IEC60754-2; EN 50267-2-2 |
| Minimum Smoke Emission | IEC 61034-2; EN 61034-2 |
600/1000V
Conductor : Annealed copper conductor, stranded according to BS EN 60228 class 2.
Fire Barrier : Mica glass tape.
Insulation : XLPE type GP 8 according to BS 7655-1.3. HEPR type GP 6 according to BS 7655-1.2 or crosslinked polyolefin material type EI 5 according to BS EN 50363-5 can be offered as option.
Inner Covering Option : The optional inner covering, where used, shall consist of an extruded layer of synthetic polymeric material. It shall surround the single core and the laid-up two, three, four or five cores, giving the assembly a practically circular shape.
Outer Sheath : Extruded layer of polymeric material LTS 4 according to BS 7655-6.1.
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.
Insulation Colour : Brown or blue.
Sheath Colour : Black; other colours can be offered upon request.
Maximum temperature range during operation : 90°C
Maximum short circuit temperature (5 Seconds) : 250°C
Minimum bending radius :
circular copper conductors OD≤25mm : 4 × Overall Diameter
circular copper conductors OD﹥25mm : 6 × Overall Diameter
shaped copper conductors : 8 × Overall Diameter
| Conductor | FRP600-mRZ1-R | |||||
|---|---|---|---|---|---|---|
| No. of Cores × Cross-sectional Area | Conductor Class | Nominal Insulation Thickness | Nominal Inner Covering Thickness | Nominal Sheath Thickness | Approx. Overall Diameter | Approx. Weight |
| No.×mm² | mm | mm | kg/km | |||
| 1×1.5 | 2 | 0.7 | 0.4 | 1.4 | 6.8 | 58 |
| 1×2.5 | 2 | 0.7 | 0.4 | 1.4 | 7.2 | 71 |
| 1×4 | 2 | 0.7 | 0.4 | 1.4 | 7.8 | 92 |
| 1×6 | 2 | 0.7 | 0.4 | 1.4 | 8.3 | 118 |
| 1×10 | 2 | 0.7 | 0.4 | 1.4 | 9.3 | 168 |
| 1×16 | 2 | 0.7 | 0.4 | 1.4 | 10.3 | 238 |
| 1×25 | 2 | 0.9 | 0.4 | 1.4 | 12.0 | 352 |
| 1×35 | 2 | 0.9 | 0.4 | 1.4 | 13.2 | 463 |
| 1×50 | 2 | 1.0 | 0.6 | 1.4 | 14.7 | 606 |
| 1×70 | 2 | 1.1 | 0.6 | 1.4 | 16.7 | 843 |
| 1×95 | 2 | 1.1 | 0.6 | 1.5 | 18.8 | 1139 |
| 1×120 | 2 | 1.2 | 0.8 | 1.5 | 20.6 | 1416 |
| 1×150 | 2 | 1.4 | 0.8 | 1.6 | 22.8 | 1736 |
| 1×185 | 2 | 1.6 | 0.8 | 1.6 | 25.0 | 2154 |
| 1×240 | 2 | 1.7 | 1.0 | 1.7 | 28.1 | 2798 |
| 1×300 | 2 | 1.8 | 1.0 | 1.8 | 30.9 | 3479 |
| 1×400 | 2 | 2.0 | 1.2 | 1.9 | 34.5 | 4419 |
| 1×500 | 2 | 2.2 | 1.2 | 2.0 | 38.2 | 5535 |
| 1×630 | 2 | 2.4 | 1.4 | 2.2 | 43.0 | 7113 |
| 1×800 | 2 | 2.6 | 1.6 | 2.3 | 47.9 | 9026 |
| 1×1000 | 2 | 2.8 | 1.6 | 2.4 | 53.0 | 11302 |
Conductor operating temperature : 90°C
Ambient temperature : 30°C
| Conductor cross-sectional area | Ref. Method A (enclosed in conduit in thermally insulating wall etc.) | Ref. Method B (enclosed in conduit on a wall or in trunking etc.) | Ref. Method C (clipped direct) | Ref. Method F (in free air or on a perforated cable tray, horizontal or vertical etc) | Ref. Method G (in free air) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Touching | Spaced by one cable diameter | ||||||||||
| 2 cables, single-phase a.c. or d.c. | 3 or 4 cables, three-phase a.c. | 2 cables, single-phase a.c. or d.c | 3 or 4 cables, three-phase a.c. | 2 cables, single-phase a.c. or d.c. flat and touching | 3 or 4 cables, three-phase a.c. flat and touching or trefoil | 2 cables, single-phase a.c. or d.c. flat | 3 cables, three-phase a.c. flat | 3 cables, three-phase a.c. trefoil | 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat | ||
| Horizontal | Vertical | ||||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| mm² | A | A | A | A | A | A | A | A | A | A | A |
| 1.5 | 19 | 17 | 23 | 20 | 25 | 23 | - | - | - | - | - |
| 2.5 | 26 | 23 | 31 | 28 | 34 | 31 | - | - | - | - | - |
| 4 | 35 | 31 | 42 | 37 | 46 | 41 | - | - | - | - | - |
| 6 | 45 | 40 | 54 | 48 | 59 | 54 | - | - | - | - | - |
| 10 | 61 | 54 | 75 | 66 | 81 | 74 | - | - | - | - | - |
| 16 | 81 | 73 | 100 | 88 | 109 | 99 | - | - | - | - | - |
| 25 | 106 | 95 | 133 | 117 | 143 | 130 | 161 | 141 | 135 | 182 | 161 |
| 35 | 131 | 117 | 164 | 144 | 176 | 161 | 200 | 176 | 169 | 226 | 201 |
| 50 | 158 | 141 | 198 | 175 | 228 | 209 | 242 | 216 | 207 | 275 | 246 |
| 70 | 200 | 179 | 253 | 222 | 293 | 268 | 310 | 279 | 268 | 353 | 318 |
| 95 | 241 | 216 | 306 | 269 | 355 | 326 | 377 | 342 | 328 | 430 | 389 |
| 120 | 278 | 249 | 354 | 312 | 413 | 379 | 437 | 400 | 383 | 500 | 454 |
| 150 | 318 | 285 | 393 | 342 | 476 | 436 | 504 | 464 | 444 | 577 | 527 |
| 185 | 362 | 324 | 449 | 384 | 545 | 500 | 575 | 533 | 510 | 661 | 605 |
| 240 | 424 | 380 | 528 | 450 | 644 | 590 | 679 | 634 | 607 | 781 | 719 |
| 300 | 486 | 435 | 603 | 514 | 743 | 681 | 783 | 736 | 703 | 902 | 833 |
| 400 | - | - | 683 | 584 | 868 | 793 | 940 | 868 | 823 | 1085 | 1008 |
| 500 | - | - | 783 | 666 | 990 | 904 | 1083 | 998 | 946 | 1253 | 1169 |
| 630 | - | - | 900 | 764 | 1130 | 1033 | 1254 | 1151 | 1088 | 1454 | 1362 |
| 800 | - | - | - | - | 1288 | 1179 | 1358 | 1275 | 1214 | 1581 | 1485 |
| 1000 | - | - | - | - | 1443 | 1323 | 1520 | 1436 | 1349 | 1775 | 1671 |
| Conductor cross-sectional area | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, three-phase a.c. | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ref. Methods A&B (enclosed in conduit or trunking) | Ref. Methods C & F(clipped direct, on trays or in free air) | Ref. Methods A & B (enclosed in conduit or trunking) | Ref. Methods C & F (clipped direct, on trays or in free air) | |||||||||||||||||||
| Cables touching | Cables spaced* | Cables touching, Trefoil | Cables touching, Flat | Cables spaced*, Flat | ||||||||||||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | ||||||||||||||
| mm² | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | |||||||||||||||
| 1.5 | 31 | 31 | 31 | 31 | 27 | 27 | 27 | 27 | ||||||||||||||
| 2.5 | 19 | 19 | 19 | 19 | 16 | 16 | 16 | 16 | ||||||||||||||
| 4 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | ||||||||||||||
| 6 | 7.9 | 7.9 | 7.9 | 7.9 | 6.8 | 6.8 | 6.8 | 6.8 | ||||||||||||||
| 10 | 4.7 | 4.7 | 4.7 | 4.7 | 4.0 | 4.0 | 4.0 | 4.0 | ||||||||||||||
| 16 | 2.9 | 2.9 | 2.9 | 2.9 | 2.5 | 2.5 | 2.5 | 2.5 | ||||||||||||||
| r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
| 25 | 1.85 | 1.85 | 0.31 | 1.90 | 1.85 | 0.190 | 1.85 | 1.85 | 0.28 | 1.85 | 1.60 | 0.27 | 1.65 | 1.60 | 0.165 | 1.60 | 1.60 | 0.190 | 1.60 | 1.60 | 0.27 | 1.65 |
| 35 | 1.35 | 1.35 | 0.29 | 1.35 | 1.35 | 0.180 | 1.35 | 1.35 | 0.27 | 1.35 | 1.15 | 0.25 | 1.15 | 1.15 | 0.155 | 1.15 | 1.15 | 0.180 | 1.15 | 1.15 | 0.26 | 1.20 |
| 50 | 0.99 | 1.00 | 0.29 | 1.05 | 0.99 | 0.180 | 1.00 | 0.99 | 0.27 | 1.00 | 0.87 | 0.25 | 0.90 | 0.86 | 0.155 | 0.87 | 0.86 | 0.180 | 0.87 | 0.86 | 0.26 | 0.89 |
| 70 | 0.68 | 0.70 | 0.28 | 0.75 | 0.68 | 0.175 | 0.71 | 0.68 | 0.26 | 0.73 | 0.60 | 0.24 | 0.65 | 0.59 | 0.150 | 0.61 | 0.59 | 0.175 | 0.62 | 0.59 | 0.25 | 0.65 |
| 95 | 0.49 | 0.51 | 0.27 | 0.58 | 0.49 | 0.170 | 0.52 | 0.49 | 0.26 | 0.56 | 0.44 | 0.23 | 0.50 | 0.43 | 0.145 | 0.45 | 0.43 | 0.170 | 0.46 | 0.43 | 0.25 | 0.49 |
| 120 | 0.39 | 0.41 | 0.26 | 0.48 | 0.39 | 0.165 | 0.43 | 0.39 | 0.25 | 0.47 | 0.35 | 0.23 | 0.42 | 0.34 | 0.140 | 0.37 | 0.34 | 0.165 | 0.38 | 0.34 | 0.24 | 0.42 |
| 150 | 0.32 | 0.33 | 0.26 | 0.43 | 0.32 | 0.165 | 0.36 | 0.32 | 0.25 | 0.41 | 0.29 | 0.23 | 0.37 | 0.28 | 0.140 | 0.31 | 0.28 | 0.165 | 0.32 | 0.28 | 0.24 | 0.37 |
| 185 | 0.25 | 0.27 | 0.26 | 0.37 | 0.26 | 0.165 | 0.30 | 0.25 | 0.25 | 0.36 | 0.23 | 0.23 | 0.32 | 0.22 | 0.140 | 0.26 | 0.22 | 0.165 | 0.28 | 0.22 | 0.24 | 0.33 |
| 240 | 0.190 | 0.21 | 0.26 | 0.33 | 0.20 | 0.160 | 0.25 | 0.195 | 0.25 | 0.31 | 0.185 | 0.22 | 0.29 | 0.170 | 0.140 | 0.22 | 0.170 | 0.165 | 0.24 | 0.170 | 0.24 | 0.29 |
| 300 | 0.155 | 0.175 | 0.25 | 0.31 | 0.160 | 0.160 | 0.22 | 0.155 | 0.25 | 0.29 | 0.150 | 0.22 | 0.27 | 0.140 | 0.140 | 0.195 | 0.135 | 0.160 | 0.21 | 0.135 | 0.24 | 0.27 |
| 400 | 0.120 | 0.140 | 0.25 | 0.29 | 0.130 | 0.155 | 0.20 | 0.125 | 0.24 | 0.27 | 0.125 | 0.22 | 0.25 | 0.110 | 0.135 | 0.175 | 0.110 | 0.160 | 0.195 | 0.110 | 0.24 | 0.26 |
| 500 | 0.093 | 0.120 | 0.25 | 0.28 | 0.105 | 0.155 | 0.185 | 0.098 | 0.24 | 0.26 | 0.100 | 0.22 | 0.24 | 0.090 | 0.135 | 0.160 | 0.088 | 0.160 | 0.180 | 0.085 | 0.24 | 0.25 |
| 630 | 0.072 | 0.100 | 0.25 | 0.27 | 0.086 | 0.155 | 0.175 | 0.078 | 0.24 | 0.25 | 0.088 | 0.21 | 0.23 | 0.074 | 0.135 | 0.150 | 0.071 | 0.160 | 0.170 | 0.068 | 0.23 | 0.24 |
| 800 | 0.056 | - | 0.072 | 0.150 | 0.170 | 0.064 | 0.24 | 0.25 | - | 0.062 | 0.130 | 0.145 | 0.059 | 0.155 | 0.165 | 0.055 | 0.23 | 0.24 | ||||
| 1000 | 0.045 | - | 0.063 | 0.150 | 0.165 | 0.054 | 0.24 | 0.24 | - | 0.055 | 0.130 | 0.145 | 0.050 | 0.155 | 0.165 | 0.047 | 0.23 | 0.24 | ||||
Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance
KEY FEATURES
- Designed according to BS 8573 requirements
- 600/1000V voltage rating
- Single core cable construction
- Mica tape fire barrier
- XLPE insulated conductor
- LSZH sheathed construction
- Fire resistant cable design
- Low smoke performance
- Halogen-free sheath material
- Suitable for critical power circuits
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Conductor size
- Conductor material
- Cable length
- Fire performance requirement
- Sheath colour
- Installation method
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
600/1000V single core Mica + XLPE
LSZH cable is commonly selected for
critical building and infrastructure projects.
It is suitable where circuit integrity,
flame retardance and low smoke
halogen-free performance are required.
RELATED CABLE TYPES
- BS 8573 cable
- BS 6387 fire resistant cable
- IEC 60331 fire resistant cable
- BS 8491 fire resistant cable
- Mica tape cable
- XLPE insulated fire resistant cable
- LSZH fire resistant cable
- Single core fire resistant cable
- FirePro cable
- 600/1000V power cable
FAQ
What is this cable used for?
It is used for critical power circuits
where fire safety is important.
It is suitable for power stations,
metro systems, tunnels, airports,
hospitals, hotels and high-rise buildings.
What standard does this cable follow?
The cable design is based on BS 8573.
Fire performance can be supplied according to
BS 6387, IEC 60331 and BS 8491 requirements,
subject to the project specification.
What is the function of mica tape?
Mica tape helps maintain circuit integrity
during fire conditions.
It supports continued operation of
critical circuits for a specified time.
Is this cable LSZH?
Yes. This cable has an LSZH sheath.
The sheath helps reduce smoke emission
and corrosive gas release in the event of fire.
Is this cable armoured?
No. This page is for single core
unarmoured fire resistant cable.
If armoured construction is required,
please confirm it separately.
Is this cable multicore?
No. This page is for single core cable.
Multicore fire resistant cable
is available as a separate type.
Can this cable be used underground?
It can be used in protected ducts
or protected underground routes.
For direct burial or demanding routes,
armoured cable may be required.
What information is required for quotation?
Please confirm voltage rating,
conductor size, cable length
and fire performance requirement.
Installation method, sheath colour,
standard and destination port
are also required.
Can BURYCABLE supply BS 8573
single core Mica XLPE LSZH cable?
Yes. BURYCABLE can supply BS 8573
600/1000V single core Mica + XLPE
insulated LSZH fire resistant cables.
We can support different conductor sizes,
lengths and packing requirements.