BS6724 LSZH armoured power cable
1900/3300V is designed for fixed
power distribution systems.
It is suitable for buildings,
infrastructure projects, substations,
industrial plants, transport systems,
utility networks and protected power routes.
The cable is designed for installations
where low smoke zero halogen performance
and mechanical protection are required.
The XLPE insulation provides reliable
electrical performance and thermal stability.
The LSZH sheath helps reduce smoke emission
and corrosive gas release in the event of fire.
The armoured construction provides
mechanical protection for demanding
installation routes.
Single core cables are normally supplied
with non-magnetic armour such as AWA.
Multicore cables are normally supplied
with steel wire armour such as SWA or GSWA.
This cable is commonly installed on cable trays,
in ducts, in risers, in plant rooms,
substations and protected underground routes.
It is suitable for fixed installations
where flame retardance, low smoke performance
and mechanical protection are required.
The cable should be selected according to
voltage rating, number of cores,
conductor size, conductor material,
armour type, installation method
and project specification.
| Conductor | Solid Aluminum or Annealed Copper conductor, circular or shaped, Class 2 to BS EN60228. |
| Insulation | XLPE (Cross-Linked Polyethylene) Type GP 8 conforming to BS 7655-1.3 or type GP 6 conforming to BS 7655-1.2. |
| Colour Code | 1 Core : Brown or Blue |
| 2 Cores : Brown, Blue | |
| 3 Cores : Brown, Black, Grey | |
| 4 Cores : Blue, Brown, Black, Grey | |
| 5 Cores : Green/Yellow, Blue, Brown, Black, Grey | |
| Above 5 Cores : White Cores with black numbers | |
| Bedding | The bedding shall consist of an extruded layer of polymeric material consistent with the operating temperature of the cable. |
| Armour | Single Core : AWA (Aluminum Wire Armour) |
| Multi Core : GSWA (Galvanized Steel Wire Armour) | |
| Outer Sheath | LSOH (Low Smoke Zero Halogen),conforming to BS 7655-6.1. |
| Voltage rating | 1900/3300V |
| Temperature rating | 0°C to +90°C |
| Bending radius | 1.5mm² to 16mm² : 6 x overall diameter |
| 25mm² and above : 8 x overall diameter | |
| Flame retardant | BS EN 60332-1-2 ; BS EN 60332-3-24:2009 |
| Halogen free | BS EN 60754-1 |
| Smoke density | BS EN 61034-2 |
KEY FEATURES
- Designed according to BS6724 requirements
- 1900/3300V voltage rating
- XLPE insulated conductors
- LSZH outer sheath
- Low smoke zero halogen performance
- Armoured cable construction
- Single core and multicore options available
- AWA armour commonly used for single core cables
- SWA or GSWA armour commonly used for multicore cables
- Suitable for fixed power distribution
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Number of cores
- Conductor size
- Conductor material
- Cable length
- Armour type
- Sheath colour
- Installation method
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
BS6724 LSZH armoured power cable
1900/3300V is commonly selected for
fixed power distribution where mechanical
protection and low smoke zero halogen
performance are required.
For single core AC circuits,
non-magnetic armour such as AWA
is normally recommended.
For multicore cables,
steel wire armour such as SWA or GSWA
is commonly used.
RELATED CABLE TYPES
- BS6724 600/1000V cable
- BS6724 single core cable
- BS6724 multicore cable
- BS5467 1900/3300V cable
- BS7846 cable
- BS7211 cable
- IEC 60502 power cable
- XLPE insulated power cable
- LSZH power cable
- Armoured power cable
FAQ
What is BS6724 1900/3300V cable used for?
BS6724 1900/3300V cable is used for
fixed power distribution systems.
It is suitable for buildings,
infrastructure projects, substations,
industrial plants, transport systems
and utility networks.
What is the voltage rating of this cable?
This page is for BS6724 1900/3300V
LSZH armoured power cable.
Is BS6724 cable LSZH?
Yes. BS6724 cable uses a low smoke
zero halogen sheath.
It helps reduce smoke emission
and corrosive gas release in the event of fire.
Is this cable fire resistant?
BS6724 cable has flame retardant
and LSZH performance.
It should not be described as a
BS6387 circuit integrity fire resistant cable
unless mica tape and circuit integrity
performance are specified.
Is this cable armoured?
Yes. This page is for armoured
BS6724 power cable.
Single core cables are normally supplied
with AWA armour.
Multicore cables are normally supplied
with SWA or GSWA armour.
Can BS6724 1900/3300V cable be used underground?
It can be used in protected underground
routes, ducts and cable trenches.
Direct burial suitability should be confirmed
according to project specification
and local installation requirements.
What information is required for quotation?
Please confirm voltage rating,
number of cores, conductor size,
conductor material, armour type
and cable length.
Installation method, sheath colour,
standard and destination port
are also required.
Can BURYCABLE supply BS6724
1900/3300V LSZH armoured power cable?
Yes. BURYCABLE can supply BS6724
1900/3300V XLPE insulated LSZH
sheathed armoured power cables.
We can support single core and multicore
constructions, copper or aluminium conductors,
different armour types, lengths
and packing requirements.