Flame Retardant RS485 Databus Cables
APPLICATIONThe cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interfer…
Flame Retardant RS485 Databus Cables.pdf Contact us

APPLICATION

The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

STANDARDS

Basic design adapted to EIA/TIA 485

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test) : BS EN 60332-1-2

CABLE CONSTRUCTION

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.

Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Aluminum/polyester tape with tinned copper drain wire.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 OVERALL DOUBLE SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.

Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Aluminium/polyester tape+copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 INDIVIDUAL & OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.

Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Individual Screen: Individual aluminium/polyester tape.

Overall Screen: Copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

MULTIPAIR RS 485 OVERALL SCREENED DATABUS CABLE

Conductors: Tinned copper wire, stranded according to IEC 60228 class 2 or class5.

Insulation: Foam PE or foam skin PE.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.

Two pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers.

Overall Screen: Copper wire braid.

Outer Sheath: Thermoplastic PVC compound.

Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

PHYSICAL AND THERMAL PROPERTIES

Temperature range during operation (fixed state) : -20°C - +90°C

Temperature range during installation (mobile state) : -5°C - +60°C

Minimum bending radius : 8 x Overall Diameter

ELECTRICAL PROPERTIES

Dielectric test1000 V r.m.s. for 5’ (core-core)
1000 V r.m.s. for 5’ (core-screen)
Impedance120Ω
Capacitance45 nF/km conductor to conductor
90 nF/km conductor to shield

CONSTRUCTION PARAMETERS

Multipair RS 485 Overall Screened Databus Cable

RE-02Y(St)Y / RE-02YS(St)Y

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm2No/mmmmmmmmkg/km
10.227/0.20.71.15.740
20.227/0.20.71.19.072
40.227/0.20.71.110.3103
10.5016/0.20.71.16.252
20.5016/0.20.71.110.195
40.5016/0.20.71.111.7143
10.7524/0.20.71.16.761
20.7524/0.20.71.110.9114
40.7524/0.20.71.112.7176
11.0030/0.20.71.16.867
21.0030/0.20.71.111.2122
41.0030/0.20.71.113.0192

Multipair RS 485 Overall Double Screened Databus Cable

RE-02Y(St)CY / RE-02YS(St)CY

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm2No/mmmmmmmmkg/km
10.227/0.20.71.16.255
20.227/0.20.71.19.498
40.227/0.20.71.110.8133
10.5016/0.20.71.16.768
20.5016/0.20.71.110.6124
40.5016/0.20.71.112.1177
10.7524/0.20.71.17.179
20.7524/0.20.71.111.4146
40.7524/0.20.71.113.2214
11.0030/0.20.71.17.385
21.0030/0.20.71.111.7154
41.0030/0.20.71.113.5231

Multipair RS 485 Individual & Overall Screened Databus Cable

RE-02Y(St)CY PiMF / RE-02YS(St)CY PiMF

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm2No/mmmmmmmmkg/km
10.227/0.20.71.16.456
20.227/0.20.71.110.2101
40.227/0.20.71.111.7139
10.5016/0.20.71.17.069
20.5016/0.20.71.111.4128
40.5016/0.20.71.113.2184
10.7524/0.20.71.17.580
20.7524/0.20.71.112.3150
40.7524/0.20.71.114.3221
11.0030/0.20.71.17.686
21.0030/0.20.71.112.6159
41.0030/0.20.71.114.7238

Multipair RS 485 Overall Screened Databus Cable

RE-02YCY / RE-02YSCY

No.of PairNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.mm2No/mmmmmmmmkg/km
10.227/0.20.71.16.051
20.227/0.20.71.19.291
40.227/0.20.71.110.6126
10.5016/0.20.71.16.564
20.5016/0.20.71.110.4117
40.5016/0.20.71.112.0169
10.7524/0.20.71.16.974
20.7524/0.20.71.111.2138
40.7524/0.20.71.113.0205
11.0030/0.20.71.17.180
21.0030/0.20.71.111.5147
41.0030/0.20.71.113.3222