PVC Cat5E Flame Retardant Data Cable, U/UTP, F/UTP and SF/UTP
PVC-sheathed Cat5E cable for fixed voice and Ethernet cabling. Four 24 AWG solid-copper pairs are available unshielded, foil-screened or foil-and-braid-screened, with transmission data through 100 MHz.
Flame Retardant CAT5E Data Cables.pdf Contact us

APPLICATION AND DESCRIPTION

This PVC Cat5E range provides four-pair copper cabling for fixed voice and Ethernet connections. The conductors are solid bare copper with PE insulation, enclosed by a thermoplastic PVC sheath. U/UTP, F/UTP and SF/UTP versions cover unshielded, foil-screened and foil-plus-braid-screened installations. The fire-performance section specifies the BS EN 60332-1-2 single-cable flame test.

STANDARDS

ISO/IEC 11801 , EN 50173 , ANSI/TIA/EIA 568

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test) :BS EN 60332-1-2

CABLE CONSTRUCTION

Conductor : 24AWG solid bare copper.

Insulation : PE.

Twinning : Two coloured insulated conductors twisted together to form a pair.

Outer Sheath : Thermoplastic PVC compound.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

Cat5EF/UTP : These cables have collective shielding of Aluminium/polyester tape with drain wire.

Cat5ESF/UTP : These cables have double collective shielding of Aluminium/polyester tape & copper wire braid.

PHYSICAL AND THERMAL PROPERTIES

Temperature range : -30°C - +75°C

Minimum bending radius during installation (mobile state) : 8 x Overall Diameter

Minimum bending radius during operation (fixed state) : 4 x Overall Diameter

ELECTRICAL PROPERTIES

AWG
24
Nominal Conductor Diametermm0.50/0.51/0.53
Maximum DC Resistance@20°CΩ/100m9.38
Maximum DCR Unbalance%5
Maximum Mutual CapacitancepF/m55.8
Maximum Capacitance UnbalancepF/100m330
Characteristic Impedance@1-100MHzΩ100±15
Maximum Propagation Delay Skewns/100m45

TRANSMISSION PROPERTIES

FREQAttenuationNEXTPSNEXTELFEXTPSELFEXTRL
MHzdB/100mdBdBdB/100mdB/100mdB
0.7721.867.064.066.063.0—
12.065.362.363.860.820.2
44.156.353.351.748.723.0
85.851.848.845.742.724.5
106.550.347.343.840.825.0
168.247.344.339.736.725.0
209.345.842.837.734.725.0
2510.444.341.335.832.824.3
31.2511.742.939.933.930.923.6
62.517.038.435.427.824.821.5
10022.035.332.323.820.820.1

CONSTRUCTION PARAMETERS

Cable CodeConductor DiameterDiameter Over InsulationPairsScreenApprox. Overall Diameter
 mmmm  mm
FLP-CAT5EU/UTP4P240.50/0.510.914Nil5.1
FLP-CAT5EF/UTP4P240.531.004Overall Aluminum Tape Screen6.3
FLP-CAT5ESF/UTP4P240.531.004Overall Aluminum Tape Screen & Copper Wire Braid6.6


KEY FEATURES

  • 24 AWG solid copper conductors and four twisted pairs.

  • PVC outer sheath with separate U/UTP, F/UTP and SF/UTP constructions.

  • 100 ± 15 ohms characteristic impedance over 1–100 MHz.

SELECTION NOTES

Choose the screen arrangement to suit the network hardware and route. The listed diameters are 5.1 mm for U/UTP, 6.3 mm for F/UTP and 6.6 mm for SF/UTP. Specify any special sheath or fire-test requirement with the cable order; the base PVC construction is distinct from the LSZH range.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Which insulation is used on the copper conductors?

PE insulation surrounds the 24 AWG solid bare copper conductors.

How is the F/UTP version screened?

It has an overall aluminium/polyester tape screen with a drain wire.

What does SF/UTP add?

An overall copper wire braid in addition to the aluminium/polyester tape screen.

Is the standard outer sheath LSZH?

The standard sheath on this page is PVC. LSZH Cat5E products are listed separately.

What is the listed temperature range?

The physical and thermal data gives −30°C to +75°C.