APPLICATION AND DESCRIPTION

Specify this armoured LSZH Cat5E range for fixed network routes requiring additional mechanical protection. Four PE-insulated copper pairs sit inside an LSZH inner sheath, followed by copper wire braid, steel wire braid or steel wire armour and an LSZH outer sheath. U/UTP, F/UTP and SF/UTP data-core options allow screening and armour to be selected separately.

STANDARDS

ISO/IEC 11801 , EN 50173 , ANSI/TIA/EIA 568

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

CABLE CONSTRUCTION

Conductors : 24AWG solid bare copper.

Insulation : PE.

Twinning : Two coloured insulated conductors twisted together to form a pair.

Inner Sheath : Thermoplastic LSZH compound.

Armouring :

CWB : Copper Wire Braid

SWB : Steel Wire Braid

SWA : Steel Wire Armour

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

Cat5EF/UTP : These cables have collective shielding of Aluminium/polyester tape with drain wire.

Cat5ESF/UTP : These cables have double collective shielding of Aluminium/polyester tape & copper wire braid.

PHYSICAL AND THERMAL PROPERTIES

Temperature range : -30°C - +75°C

Minimum bending radius during installation (mobile state) : 8 x Overall Diameter

Minimum bending radius during operation (fixed state) : 4 x Overall Diameter

ELECTRICAL PROPERTIES

AWG 24
Nominal Conductor Diametermm0.50/0.51/0.53
Maximum DC Resistance@20°CΩ/100m9.38
Maximum DCR Unbalance%5
Maximum Mutual CapacitancepF/m55.8
Maximum Capacitance UnbalancepF/100m330
Characteristic Impedance@1-100MHzΩ100±15
Maximum Propagation Delay Skewns/100m45

TRANSMISSION PROPERTIES

FREQAttenuationNEXTPSNEXTELFEXTPSELFEXTRL
MHzdB/100mdBdBdB/100mdB/100mdB
0.7721.867.064.066.063.0—
12.065.362.363.860.820.0
44.156.353.351.748.723.0
85.851.848.845.742.724.5
106.550.347.343.840.825.0
168.247.344.339.736.725.0
209.345.842.837.734.725.0
2510.444.341.335.832.824.3
31.2511.742.939.933.930.923.6
62.517.038.435.427.824.821.5
10022.035.332.323.820.820.1

CONSTRUCTION PARAMETERS

Cable CodeConstruction No. of Elements×No. of Cores in Element×Conductor DiameterNominal Insulation ThicknessNominal Inner Sheath ThicknessNominal Outer Sheath ThicknessAprrox. Overall DiameterNominal Weight
mmmmmmmmmmkg/km
FLP-CAT5EU/UTP4P24LH CWB4×2×0.50.20.61.07.68102
FLP-CAT5EU/UTP4P24LH SWB4×2×0.50.20.61.07.6898
FLP-CAT5EU/UTP4P24LH SWA4×2×0.50.20.61.08.68170
FLP-CAT5EF/UTP4P24LH CWB4×2×0.530.20.61.08.28121
FLP-CAT5EF/UTP4P24LH SWB4×2×0.530.20.61.08.28117
FLP-CAT5EF/UTP4P24LH SWA4×2×0.530.20.61.09.28197
FLP-CAT5ESF/UTP4P24LH CWB4×2×0.530.20.61.08.76128
FLP-CAT5ESF/UTP4P24LH SWB4×2×0.530.20.61.08.76124
FLP-CAT5ESF/UTP4P24LH SWA4×2×0.530.20.61.09.76221


KEY FEATURES

  • 24 AWG solid bare copper conductors in four twisted pairs.

  • CWB, SWB and SWA armour options, each offered with three data-core screen arrangements.

  • LSZH inner sheath and thermoplastic LSZH LTS3 outer sheath.

SELECTION NOTES

State both the data-core screen type and the armour type in the cable schedule. Their combination determines diameter and weight, which range from 7.68 to 9.76 mm and 98 to 221 kg/km in the table. Select glands and termination hardware for the exact construction; specify environmental sheath options separately.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

What do CWB, SWB and SWA mean?

Copper wire braid, steel wire braid and steel wire armour respectively.

Can an armoured version still be designated U/UTP?

Yes. U/UTP describes the unshielded data-core assembly. The separate armour layer is outside the inner sheath.

Are all nine constructions the same size?

No. The screen and armour combination changes the overall diameter and nominal weight; each combination has its own table row.

Which sheath materials surround the armour?

A thermoplastic LSZH inner sheath and an LSZH outer sheath surround it.

Which bend limit applies while laying the cable?

The listed installation limit is eight times the overall diameter; the fixed-state limit is four times the diameter.