G7623 A2 cable is intended for internal communication wiring in railway stations, buildings and equipment rooms where the project calls for a limited-fire-hazard construction. Tinned annealed solid copper conductors have LSZH insulation and are assembled into twisted pairs and stranded units. Non-hygroscopic wrapping tape and an LSZH sheath surround the core assembly.
LUL Spec G7623 A2
Core IdentificationConductoBR: Tinned annealed solid copper, 0.5/0.6/0.63 mm nominal diameter.
Insulation: LSZH Insulation.
Cabling Element: Two insulated conductoBR are twisted together to form a pair.
Stranding: Cables are composed of unit stranding.
Core Wrapping: Non-hygroscopic plastic tape with overlapping.
Outer Sheath: LSZH sheath.
| Nominal Conductor Diameter | mm | 0.5 | 0.6 | 0.63 |
| Maximum Conductor Resistance | Ω/km | 98 | 68 | 58 |
| Minimum Insulation Resistance @500 V DC | MΩ.km | 120 | 120 | 120 |
| Maximum Average Mutual Capacitance @1KHz | nF/km | 80 | 80 | 80 |
| Maximum Average Capacitance Unbalance @800Hz pair-to-pair | 500 | 500 | 500 | |
| Test Voltage AC 1min | V | 500 | 500 | 500 |
Minimum Bending Radius: 7.5×OD
Temperature Range: -30℃ to +70℃ (during operation); -10℃ +55℃ (during installation)
| Cable Code | No. of paiBR | Minimum Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|---|
| 0.5mm Conductor, 0.82mm Insulated Wire | ||||
| BR7623A2-HH-1P0.5 | 1 | 1.3 | 6.0 | 30 |
| BR7623A2-HH-2P0.5 | 2 | 1.3 | 7.0 | 45 |
| BR7623A2-HH-3P0.5 | 3 | 1.4 | 7.0 | 50 |
| BR7623A2-HH-6P0.5 | 6 | 1.5 | 9.0 | 61 |
| BR7623A2-HH-10P0.5 | 10 | 1.6 | 11.0 | 107 |
| BR7623A2-HH-20P0.5 | 20 | 1.9 | 14.0 | 190 |
| BR7623A2-HH-40P0.5 | 40 | 1.9 | 16.0 | 320 |
| BR7623A2-HH-80P0.5 | 80 | 2.2 | 23.0 | 640 |
| BR7623A2-HH-100P0.5 | 100 | 2.2 | 25.0 | 760 |
| BR7623A2-HH-160P0.5 | 160 | 2.6 | 29.0 | 1150 |
| 0.6mm Conductor, 1.12mm Insulated Wire | ||||
| BR7623A2-HH-1P0.6 | 1 | 1.4 | 6.0 | 35 |
| BR7623A2-HH-2P0.6 | 2 | 1.4 | 7.0 | 50 |
| BR7623A2-HH-3P0.6 | 3 | 1.5 | 7.0 | 60 |
| BR7623A2-HH-6P0.6 | 6 | 1.6 | 9.0 | 85 |
| BR7623A2-HH-10P0.6 | 10 | 1.7 | 11.0 | 145 |
| BR7623A2-HH-20P0.6 | 20 | 2.2 | 14.0 | 245 |
| BR7623A2-HH-40P0.6 | 40 | 2.2 | 18.0 | 410 |
| BR7623A2-HH-80P0.6 | 80 | 2.8 | 25.0 | 830 |
| BR7623A2-HH-100P0.6 | 100 | 2.8 | 27.0 | 980 |
| BR7623A2-HH-160P0.6 | 160 | 3.2 | 33.0 | 1450 |
| 0.63mm Conductor, 1.15mm Insulated Wire | ||||
| BR7623A2-HH-1P0.63 | 1 | 1.4 | 5.5 | 40 |
| BR7623A2-HH-3P0.63 | 3 | 1.5 | 7.3 | 70 |
| BR7623A2-HH-5P0.63 | 5 | 1.6 | 8.5 | 89 |
| BR7623A2-HH-6P0.63 | 6 | 1.6 | 8.9 | 100 |
| BR7623A2-HH-10P0.63 | 10 | 1.7 | 11.1 | 170 |
| BR7623A2-HH-12P0.63 | 12 | 1.7 | 11.6 | 195 |
| BR7623A2-HH-160P0.63 | 160 | 3.2 | 35.0 | 1595 |
Tinned solid copper in 0.5, 0.6 and 0.63 mm nominal conductor diameters.
LSZH insulation and outer sheath with twisted-pair unit construction.
Multiple pair counts with separate dimensions for each conductor-size group.
Choose conductor diameter and pair count as a complete cable code; the available pair counts differ between size groups. Use the corresponding diameter and weight when planning supports and terminations. A reference to LUL Spec G7623 A2 identifies the cable specification; project acceptance and documentation should be agreed for the installation.
Where is G7623 cable intended to be installed?
Internally within station buildings and equipment rooms requiring the specified limited-fire-hazard construction.
Are the conductors bare or tinned copper?
The construction uses tinned annealed solid copper conductors.
Which parts use LSZH material?
Both the conductor insulation and the outer sheath are specified as LSZH.
Does every conductor size have the same pair-count range?
The table lists different available pair counts under the 0.5, 0.6 and 0.63 mm conductor groups. Select the complete listed construction.
What minimum bend radius is listed?
The mechanical data specifies 7.5 times the overall cable diameter.