H05V2V2-F / H05V2V2H2-F Heat Resistant PVC Cable, 300/500V
Heat-resistant PVC flexible cables rated 300/500V, with TI3 insulation and a TM3 sheath. Compare round H05V2V2-F and flat H05V2V2H2-F constructions for indoor appliance and lighting connections.
H05V2V2-F H05V2V2H2-F.pdf Contact us

APPLICATION AND DESCRIPTION

This heat-resistant PVC range provides flexible supply connections for indoor household appliances, lighting and light portable equipment. H05V2V2-F is the round construction and H05V2V2H2-F is the flat construction. Both use fine-stranded copper, TI3 PVC insulation and a TM3 PVC sheath, with a rated voltage of 300/500V and a maximum normal conductor temperature of 90°C.

STANDARD AND APPROVAL

  • CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1

CABLE CONSTRUCTION

Technical Characteristics

Bare copper fine wire conductor
Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383
PVC core insulation TI3 to VDE-0281 Part 1
Green-yellow grounding (3 conductors and above)
Color coded to VDE-0293-308
PVC outer jacket TM3

 

Working voltage300/500 volts
Test voltage2000 volts
Flexing bending radius15 x O
Static bending radius4 x O
Flexing temperature+5o C to +90o C
Static temperature-40o C to +90o C
Short circuit temperature+160o C
Flame retardantIEC 60332.1
Insulation resistance20 MΩ x km

CABLE PARAMETER

AWGNo. of Cores x Nominal Cross Sectional AreaNominal Thickness of InsulationNominal Thickness of SheathNominal Overall DiameterNominal Copper WeightNominal Weight

# x mm^2mmmmmmkg/kmkg/km
H05V2V2-F
18(24/32)2 x 0.750.60.86.214.454.2
18(24/32)3 x 0.750.60.86.621.665
18(24/32)4 x 0.750.60.87.12977.7
18(24/32)5 x 0.750.60.983697.3
17(32/32)2 x 1.000.60.86.41960.5
17(32/32)3 x 1.000.60.86.82973.1
17(32/32)4 x 1.000.60.97.63893
17(32/32)5 x 1.000.60.98.348111.7
16(30/30)2 x 1.500.70.87.42982.3
16(30/30)3 x 1.500.70.98.143104.4
16(30/30)4 x 1.500.71.0958131.7
16(30/30)5 x 1.500.71.11072163.1
14(50/30)2 x 2.500.81.09.248129.1
14(50/30)3 x 2.500.81.11072163
14(50/30)4 x 2.500.81.110.996199.6
14(50/30)5 x 2.500.81.212.4120245.4
12(56/28)3 x 4.000.81.211.3115224
12(56/28)4 x 4.000.81.212.5154295
12(56/28)5 x 4.000.81.413.7192361
10(84/28)3 x 6.000.81.113.1181328
10(84/28)4 x 6.000.81.313.9230490
H05V2V2H2-F
18(24/32)2 x 0.750.60.84.2 x 6.814.148
17(32/32)2 x 1.000.60.84.4 x 7.21957


KEY FEATURES

  • Class 5 bare copper conductors with heat-resistant PVC insulation and sheath.

  • Round and flat constructions are identified separately in the parameter table.

  • Core-count, area and dimension combinations support cord-entry and termination selection.

SELECTION NOTES

Choose the cable shape to suit the equipment entry and cord grip, then select conductor area and the protective conductor arrangement. Keep the route away from hot components and radiant heat. The 90°C figure is a conductor-temperature limit; it does not establish the permissible surrounding temperature for every load or installation.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

What is the difference between the two designations?

H05V2V2-F is round; H05V2V2H2-F is flat. The table separates their dimensional data.

Which compounds provide the heat-resistant construction?

TI3 PVC is used for core insulation and TM3 PVC for the outer sheath.

Does 90°C describe the surrounding air temperature?

It is the maximum conductor temperature in normal use. Ambient conditions and load must be considered together.

Can this cable be routed against a heating element?

The application requires separation from hot parts and radiant heat, even with the heat-resistant PVC construction.

Which information helps select a cord grip?

Use the overall diameter for a round construction or both overall dimensions for a flat construction, together with the equipment’s retention requirements.