Medium Wall Multicore Unscreened Cables 300/500 V or 0.6/1 kV
APPLICATION-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.-Used in control,auxillary and main circuit wiring such as cable ha…
EN 50264-3-2 Medium Wall Multicore Unscreened Cables.pdf Contact us

APPLICATION

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control,auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorFlexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
InsulationLSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EI 104)
Outer SheathLSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EI 104)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300/500 V or 0.6/1 kV
Maximum Conductor Temperature90°C ( fixed installation )
Minimum Permissible Ambient Temperature-25°C/-40°C ( fixed installation )
Bending Radius

Fixed installation :

4 x Overall Diameter (D<12mm);

5 x Overall Diameter (D>12mm)

Flexible installation :

8 x Overall Diameter (D<12mm);

10 x Overall Diameter (D>12mm)

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN 54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073; NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815Halogen Free

EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813

Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN50200: 2000Resistance to fire of unprotected small cable for use in emergency circuits 4 classifications are defined: PH 15,30,60, or 90mins;
IEC60331-21The circuit integrity test under fire of cables rated 0.6/1.0kV and below
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL MW-05M 300/500 V

Nominal Cross-Sectional Area (a)Conductor Diameter (b)Min. Mean Thickness of InsulationCore DimensionsMin. Average Sheath ThicknessOverall DiameterWeightMax. Conductor ResistanceMin. Insulation Resistance
EI 110EI 106/7/8/9
Min. Acc.to ENMax. Acc.to ENMin.Max.20°C20°C20°C
n x mm²mmmmmmmmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
2 x 11.250.42.02.40.65.36.24020.015.07.5
4 x 11.250.42.02.40.66.17.27020.015.07.5
7 x 11.250.42.02.40.77.58.712020.015.07.5
9 x 11.250.42.02.40.79.110.616020.015.07.5
12 x 11.250.42.02.40.79.811.519020.015.07.5
19 x 11.250.42.02.40.811.713.729020.015.07.5
24 x 11.250.42.02.41.014.116.539020.015.07.5
32 x 11.250.42.02.41.015.518.249020.015.07.5
37 x 11.250.42.02.41.016.118.955020.015.07.5
40 x 11.250.42.02.41.016.719.660020.015.07.5

4 x 1.51.50.52.42.90.77.38.611013.714.07.0
7 x 1.51.50.52.42.90.78.710.217013.714.07.0
9 x 1.51.50.52.42.90.810.912.723013.714.07.0
12 x 1.51.50.52.42.90.811.813.828013.714.07.0
19 x 1.51.50.52.42.91.014.216.644013.714.07.0
24 x 1.51.50.52.42.91.016.619.556013.714.07.0
32 x 1.51.50.52.42.91.218.721.972013.714.07.0
37 x 1.51.50.52.42.91.219.522.882013.714.07.0

4 x 2.51.950.52.93.40.78.39.81508.2113.06.5
7 x 2.51.950.52.93.40.810.211.92408.2113.06.5
9 x 2.51.950.52.93.41.012.915.13508.2113.06.5
12 x 2.51.950.52.93.41.013.916.34208.2113.06.5
19 x 2.51.950.52.93.41.016.319.16408.2113.06.5
24 x 2.51.950.52.93.41.219.622.98408.2113.06.5

(a)= One earth conductor (green/yellow) can be included upon request

(b)= For information, indicative only

BRAIL MW-1M 0.6/1 KV

Nominal Cross-Sectional Area (a)Conductor Diameter (b)Min. Mean Thickness of InsulationCore DimensionsMin. Average Sheath ThicknessOverall DiameterWeightMax. Conductor ResistanceMin. Insulation Resistance
EI 110EI 106/7/8/9
Min. Acc.to ENMax. Acc.to ENMin.Max.20°C20°C20°C
n x mm²mmmmmmmmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
TWO CORES
1.51.50.72.83.30.707.29.07013.721.010.5
2.51.950.73.23.80.708.010.01008.2117.28.6
42.50.73.84.40.709.111.31305.0914.27.1
63.00.74.25.00.8010.112.41703.3912.26.1
103.90.75.15.91.0012.515.42901.959.84.9
165.00.76.17.21.0014.918.43901.247.93.9
256.40.97.89.11.2018.723.05900.7957.33.6
357.70.99.010.61.2021.225.97900.5656.73.3
509.21.010.612.41.4025.130.711400.3936.33.1
THREE CORES
1.51.50.72.83.30.707.79.510013.721.010.5
2.51.950.73.23.80.708.510.51308.2117.28.6
42.50.73.84.40.709.712.01805.0914.27.1
63.00.74.25.00.8010.713.22503.3912.26.1
103.90.75.15.91.0013.316.54101.959.84.9
165.00.76.17.21.0016.019.65701.247.93.9
256.40.97.89.11.2020.024.78500.7957.33.6
357.70.99.010.61.4023.028.211600.5656.73.3
509.21.010.612.41.6026.332.216800.3936.33.1
FOUR CORES
1.51.50.72.83.30.708.510.512013.721.010.5
2.51.950.73.23.80.709.411.61708.2117.28.6
42.50.73.84.40.8010.913.42405.0914.27.1
63.00.74.25.01.0012.214.93303.3912.26.1
103.90.75.15.91.0014.718.25401.959.84.9
165.00.76.17.21.2018.022.17501.247.93.9
256.40.97.89.11.4022.627.611400.7957.33.6
3 x 35+257.7/6.40.9/0.99.0/7.810.6/9.11.4025.731.214900.565/0.7956.73.3
3 x 50+259.2/6.41.0/0.910.6/7.812.4/9.11.6030.036.521100.393/1.7956.33.1

(a)= One earth conductor (green/yellow) can be included upon request

(b)= For information, indicative only