Medium Wall Single Core Sheathed Cables 1.8/3 kV or 3.6/6 kV
APPLICATION-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.-Used in control, auxillary and main circuit wiring such as cable h…
EN 50264-3-1 Medium Wall Single Core Sheathed Cables.pdf Contact us

APPLICATION

  • -Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

  • -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorFlexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
InsulationLSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)
SheathLSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature90°C ( fixed installation )
Minimum Permissible Ambient Temperature-25°C/-40°C ( fixed installation )
Bending Radius3 x Overall Diameter (D<12mm); 4 x Overall Diameter (D>12mm)

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ; 
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074; 
NF C 20-454; VDE 0472 Teil 815
Halogen Free

EN 50267-2-2/3; IEC 60754-2; NF C 32-074;

NF C 20-453; VDE 0472 Teil 813

Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index

BRAIL MW-3S 1.8/3 KV

Nominal Cross-Sectional AreaConductor Diameter (a)Min. Mean Thickness of InsulationMin. Mean Thickness of SheathOverall DiameterWeightConductor ResistanceInsulation Resistance
minmax20℃20℃90℃
mm2mmmmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
1.51.51.30.85.76.76013.721.80.218
2.51.951.30.86.07.0708.2118.80.188
42.51.30.86.57.6905.0916.20.162
63.01.30.87.08.11103.3914.40.144
103.91.50.88.29.61701.9512.80.128
165.01.50.89.210.82401.2410.70.107
256.41.81.011.513.43500.79510.30.103
357.71.81.012.714.94500.5658.90.089
509.21.81.014.116.55900.3937.80.078
7011.01.81.015.818.57900.2776.70.067
9512.52.21.018.021.010500.2106.50.065
12014.22.21.019.622.912700.1646.10.061
15015.82.21.221.425.115900.1325.80.058
18517.52.41.223.427.419000.1085.60.056
24020.12.41.225.930.324900.08175.00.050
30022.52.41.228.132.930100.06544.50.045
40025.82.61.432.037.439800.04954.40.044

BRAIL MW-6S 3.6/6 KV

Nominal Cross-Sectional AreaConductor Diameter (a)Min. Mean Thickness of InsulationMin. Mean Thickness of SheathOverall DiameterWeightConductor ResistanceInsulation Resistance
minmax20℃20℃90℃
mm2mmmmmmmmmmkg/kmΩ/kmMΩ x kmMΩ x km
2.51.952.60.88.610.11208.2124.60.246
42.52.60.89.110.71405.0921.60.216
63.02.60.89.611.21653.3919.50.195
103.92.60.810.412.22201.9516.70.167
165.02.60.811.513.42901.2414.20.142
256.42.91.013.716.14300.79513.10.131
357.72.91.014.917.55400.56511.60.116
509.22.91.016.419.16700.39310.20.102
7011.02.91.018.021.18800.2778.90.089
9512.52.91.019.522.811000.2108.00.080
12014.22.91.221.425.113800.1647.50.075
15015.82.91.222.926.816600.1326.90.069
18517.53.21.225.129.420100.1086.70.067
24020.13.41.428.333.126700.08176.40.064
30022.53.41.430.635.831700.06545.90.059
40025.83.41.433.739.441500.04955.20.052

(a) = for information, indicative only