whatsapp
backtop
N2XH XLPE Insulated LSZH Power Cable to IEC 60502-1
N2XH XLPE insulated LSZH power cableis designed for fixed low voltagepower distribution.It is suitable for buildings, tunnels,hotels, hospitals, metro systemsand public facilities where low smokeand halogen-free performance is required.
N2XH N2XCH.pdf Contact us

Application and Description

N2XH power cables with enhanced resistance to fire are used mostly in areas where harm to human life or material must be prevented in case of fire such as industrial and public buildings, hotels, subway systems, hospitals etc. These cables are suitable for dry and wet environments as well as for outer application but are not suitable for direct burial into earth or water.

N2XH cable is an XLPE insulated

LSZH sheathed power cable.


It is designed for fixed low voltage

power distribution systems.


The cable is suitable for industrial buildings,

public buildings, hotels, hospitals,

metro systems, tunnels and commercial facilities.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH sheath helps reduce smoke emission

and corrosive gas release in the event of fire.


N2XH cable is commonly selected for areas

where human safety and equipment protection

are important.


It can be used in dry and damp locations.


It is suitable for indoor installation,

outdoor protected installation,

cable trays, ducts and protected cable routes.


It is not recommended for direct burial

without suitable mechanical protection.


The cable should be selected according to

voltage rating, number of cores,

conductor size, sheath colour,

installation method and project specification.



Standard and Approval

  • VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2

Cable Construction

Solid or stranded plain copper conductor
to DIN VDE 0295 cl. 1, cl. 2, BS 6360 cl. 1, cl. 2 and IEC 60228 cl 1, cl. 2
XLPE insulation type 2XI1, to HD 604 S1
Color coded to DIN VDE 0293-308
Green-yellow ground conductor (3 conductors and above)
Special LSOH filler
For N2XCH version with concentric conductor:
plain round copper wires and one or two transverse counter helix of copper tapes
Thermoplastic polyolefin compound outer jacket type HM4, to HD 604 S1

Technical Characteristics

Working voltage600/1000 volts
Test voltage4000 volts
Minimum bending radius12 x Ø
Flexing Temperature-5º C to +50º C
Fixed installation temperature- 40º C to +90º C
Short circuit temperature+250º C
Flame-retardantVDE 0482 part 266-2, DIN EN 50266-2 / IEC 60332-3
Low corrosiveness of combustion gasesto DIN VDE 0482 part 267/ EN 50267-2-2/IEC 60754-2
Halogen-freeto DIN VDE 0482 part 267 /EN 50267-2-1/IEC 60754-1
Smoke densityto DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2
Insulation resistance>20 MΩ x km

KEY FEATURES


- N2XH type low voltage power cable

- XLPE insulated conductor

- LSZH / halogen-free outer sheath

- Low smoke performance

- Reduced corrosive gas emission

- Suitable for fixed installation

- Suitable for public buildings

- Suitable for tunnels and metro systems

- Suitable for hotels and hospitals

- Designed for safer cable installations



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Number of cores

- Conductor size

- Conductor material

- Cable length

- Sheath colour

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


N2XH cable is commonly selected

for building power distribution.


It is suitable where LSZH performance

and halogen-free sheath construction

are required.



RELATED CABLE TYPES


- N2XY cable

- N2XH power cable

- IEC 60502-1 low voltage cable

- XLPE insulated power cable

- LSZH power cable

- Halogen free cable

- Low smoke cable

- Unarmoured power cable

- Building power cable

- Fire retardant cable



FAQ


What is N2XH cable used for?


N2XH cable is used for fixed

low voltage power distribution.


It is suitable for buildings,

public facilities, tunnels, hotels,

hospitals and metro systems.



What is the structure of N2XH cable?


N2XH cable normally has copper conductors,

XLPE insulation and LSZH sheath.


It is usually an unarmoured cable.



Is N2XH a halogen-free cable?


Yes. N2XH cable uses LSZH

or halogen-free sheath material.


It helps reduce smoke and corrosive gas

in the event of fire.



Is N2XH a fire resistant cable?


N2XH is generally a flame retardant

and halogen-free power cable.


It should not be described as a

circuit integrity fire resistant cable

unless the project standard confirms it.



Can N2XH cable be used underground?


It can be used in protected ducts

or protected cable routes.


For direct burial, armoured cable

or additional mechanical protection

may be required.



What is the difference between

N2XH and N2XY?


N2XH has an LSZH / halogen-free sheath.


N2XY normally has a PVC sheath.


N2XH is preferred where low smoke

and halogen-free performance is required.



What information is required for quotation?


Please confirm voltage rating,

number of cores, conductor size

and cable length.


Installation method, sheath colour,

standard and destination port

are also required.



Can BURYCABLE supply N2XH cable?


Yes. BURYCABLE can supply N2XH

XLPE insulated LSZH power cables.


We can support different conductor sizes,

core numbers, lengths and packing requirements.