ZPAU & ZPAU-SH Screened Main Railway Signalling Cable
ZPAU and ZPAU-SH twisted-pair railway signalling cables link control centres and trackside equipment. Corrugated copper tape and double steel tapes provide the specified screening construction for AC-electrified railway routes.
ZPAU & ZPAU-SH Main SignallingCables (AC Electrified Lines).pdf Contact us

APPLICATION

ZPAU and ZPAU-SH cables carry signalling circuits between control centres and trackside equipment shelters on AC-electrified railway routes. PE-insulated solid copper conductors are twisted into pairs. A corrugated copper tape screen, intermediate sheath and double steel tapes form the layered screening construction. The range includes ZPAU PE/PVC sheath arrangements and the ZPAU-SH LSZH option. The railway traction voltage and the signalling cable operating voltage are separate design quantities.

STANDARDS

SNCF CT 445 / SNCT ST 698G

NF F 55-698

CONSTRUCTION

Conductors : Solid annealed copper, 1.0/1.5 mm² nominal cross section area.

Insulation : Solid polyethylene.

Cabling Element : Each two conductors are twisted together to form a pair.

Stranding : Pairs are helically stranded in layers to form the cable core.

Core Wrapping : Plastic tape(s) with overlapping.

Inner Sheath : PE sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).

Electrostatic Shield : One corrugated copper tape.

Intermediate Sheath : PE/PVC sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).

Electromagnetic Shield : Two helically applied steel tapes of 0.5mm.

Outer Sheath : PE/PVC Sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).

Remarks : ZPAU : PE/PVC Sheath; ZPAU-SH : LSZH Sheath.

ELECTRICAL CHARACTERISTICS AT 20℃

Nominal Conductor Diametermm1.131.38
Nominal Cross Section Areamm²1.01.5
Maximum Conductor Resistance (DC)Ω/km18.112.31
Minimum Insulation Resistance @500 V DC (3mins)MΩ.km50005000
Maximum Mutual Capacitance @1000Hz (AC)nF/km5555
Maximum Capacitance Unbalance (pair to pair) @800Hz


    100% casespF/500 m400400
    90% casespF/500 m200200
Attenuation @45KHzdB/km2.52.5
Characteristic Impedance @45KHzΩ120120
Dielectric Strength, conductor to conductor (DC voltage 3secs)V45004500
Operating Voltage (AC/DC)V450/750450/750
Peak Value (AC)V900900

MECHANICAL AND THERMAL PROPERTIES

Minimum Bending Radius : 8×OD (static) ; 16×OD (dynamic)

Temperature Range : -40℃ to +70℃ (during operation) ; -20℃ to +50℃ (during installation)

REDUCTION FACTOR

Inductive Voltage (V/km) Em2832374247507080100120170225
Reduction Factor @50Hz Rk0.750.700.600.500.400.350.300.280.260.250.240.25

DIMENSIONS AND WEIGHT

Cable CodeNo. of PairsNominal Sheath ThicknessNominal Overall DiameterNominal Weight
InnerInterm.Outer


mmmmmmmmkg/km
1.13mm Conductor, 2.3mm Insulated Wire
BRAIL ZPAU-2Y2Y(K)2YB2Y-1P1S11.00.81.616.2490
BRAIL ZPAU-2Y2Y(K)2YB2Y-2P1S21.00.81.617.0550
BRAIL ZPAU-2Y2Y(K)2YB2Y-3P1S31.00.81.622.2820
BRAIL ZPAU-2Y2Y(K)2YB2Y-4P1S41.00.81.623.8890
BRAIL ZPAU-2Y2Y(K)2YB2Y-7P1S71.00.81.726.71080
BRAIL ZPAU-2Y2Y(K)2YB2Y-14P1S141.20.81.832.31560
BRAIL ZPAU-2Y2Y(K)2YB2Y-21P1S211.21.12.037.21990
BRAIL ZPAU-2Y2Y(K)2YB2Y-28P1S281.21.12.241.42380
BRAIL ZPAU-2Y2Y(K)2YB2Y-56P1S561.31.32.552.93700
1.38mm Conductor, 2.55mm Insulated Wire
BRAIL ZPAU-2Y2Y(K)2YB2Y-14P1.5S141.20.81.835.02050
BRAIL ZPAU-2Y2Y(K)2YB2Y-21P1.5S211.21.12.039.52525


KEY FEATURES

  • Solid copper conductors in 1.0 and 1.5 mm² constructions.

  • Twisted pairs with corrugated copper tape and double steel tape layers.

  • A reduction-factor table at 50 Hz supports project-specific induction assessment.

SELECTION NOTES

Specify pair count, conductor size and complete sheath arrangement. Assess induction using the values at the relevant field strength, together with the route geometry and bonding design. The electrical table lists operating voltage as 450/750 V AC/DC; a reference to a 25 kV railway describes the traction system. Include the selected cable diameter and installation temperature in route planning.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

What does the SH suffix identify?

ZPAU-SH identifies the LSZH sheath option. Specify the complete sheath arrangement and required fire-performance documentation.

Does use beside a 25 kV railway give the cable a 25 kV rating?

No. The traction-system voltage describes the railway environment. This cable’s operating-voltage entry is 450/750 V AC/DC.

What are the principal metallic layers?

The construction includes a corrugated copper tape electrostatic screen and two helically applied steel tapes.

Is the reduction factor constant?

It varies with the stated inductive voltage. Use the 50 Hz table for the relevant assessment conditions.

Which cable details should a procurement schedule include?

Specify ZPAU or ZPAU-SH, pair count, conductor cross-section, sheath arrangement, lengths and the required project documentation.