ZPGU Screened Local Railway Signalling Cable, 1.0 mm² Copper Pairs
ZPGU local signalling cable with 1.0 mm2 solid copper pairs, PE insulation, a tape screen and tinned copper drain wire. PVC or LSZH outer sheath options are listed for equipment-shelter connections.
ZPGU Local Signalling Cables(Ordinary Non-Electrified Lines).pdf Contact us

APPLICATION

ZPGU provides local signalling connections within trackside equipment shelters and associated equipment wiring. The cable uses 1.0 mm² class 1 solid copper conductors arranged in twisted pairs, with PE insulation and an inner PE sheath. A tape screen and tinned copper drain wire provide the screening arrangement beneath a PVC or LSZH outer sheath. Pair count and finished diameter determine the space needed at equipment entries.

STANDARDS

SNCF CT 445

NF F 55-698

CONSTRUCTION

Conductors : Class 1 solid copper, 1.0 mm² nominal cross section area.

Insulation : Solid polyethylene.

Cabling Element : Each two conductors are twisted together to form a pair.

Inner Sheath : PE.

Screen : Aluminium/Polyethylene tape screen.

Drain Wire : Tinned copper drain wire.

Outer Sheath : PVC/LSZH.

ELECTRICAL CHARACTERISTICS AT 20℃

Nominal Conductor Diametermm1.13
Nominal Cross Section Areamm²1.0
Maximum Conductor Resistance (DC)Ω/km18.1
Maximum Mutual Capacitance @1000Hz (AC)nF/km55
Operating VoltageV750

MECHANICAL AND THERMAL PROPERTIES

Minimum Bending Radius : 8×OD (static) ; 16×OD (dynamic)

Temperature Range : -40℃ to +70℃ (during operation) ; -20℃ to +50℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of PairsNominal Sheath ThicknessNominal Overall DiameterNominal Weight
InnerOuter
  mmmmmmkg/km
1.13mm Conductor, 2.3 Insulated Wire
BRAIL ZPGU-2Y2Y(L)Y-1P1S11.01.59.895
BRAIL ZPGU-2Y2Y(L)Y-2P1S21.01.510.6130
BRAIL ZPGU-2Y2Y(L)Y-3P1S31.01.513.2179
BRAIL ZPGU-2Y2Y(L)Y-7P1S71.01.718.3301
BRAIL ZPGU-2Y2Y(L)Y-14P1S141.21.821.3532


KEY FEATURES

  • 1.0 mm² solid copper conductors with a nominal diameter of 1.13 mm.

  • One, two, three, seven and fourteen-pair arrangements in the dimension schedule.

  • Tape screening with a dedicated drain wire and PVC or LSZH sheath options.

SELECTION NOTES

Select the pair count from the circuit schedule and identify the sheath material for the installation. Coordinate screen continuity and drain-wire termination with the equipment design. Use the listed overall diameter for entries and supports, and the 8 times static or 16 times dynamic bend-radius figures when planning the route.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Is ZPGU a solid or stranded conductor cable?

The listed construction uses class 1 solid copper conductors.

Which conductor size is specified?

The nominal cross-section is 1.0 mm², with a nominal conductor diameter of 1.13 mm.

Does ZPGU include steel tape armour?

This construction lists a tape screen and drain wire, without a steel tape armour layer.

What sheath options are listed?

PVC and LSZH outer sheath options are listed. Include the required material in the order.

What should accompany a local-circuit cable enquiry?

Provide pair count, route length, sheath choice, equipment-entry size and the screen-termination requirements.