ZPGU provides local signalling connections within trackside equipment shelters and associated equipment wiring. The cable uses 1.0 mm² class 1 solid copper conductors arranged in twisted pairs, with PE insulation and an inner PE sheath. A tape screen and tinned copper drain wire provide the screening arrangement beneath a PVC or LSZH outer sheath. Pair count and finished diameter determine the space needed at equipment entries.
SNCF CT 445
NF F 55-698
Conductors : Class 1 solid copper, 1.0 mm² nominal cross section area.
Insulation : Solid polyethylene.
Cabling Element : Each two conductors are twisted together to form a pair.
Inner Sheath : PE.
Screen : Aluminium/Polyethylene tape screen.
Drain Wire : Tinned copper drain wire.
Outer Sheath : PVC/LSZH.
| Nominal Conductor Diameter | mm | 1.13 |
| Nominal Cross Section Area | mm² | 1.0 |
| Maximum Conductor Resistance (DC) | Ω/km | 18.1 |
| Maximum Mutual Capacitance @1000Hz (AC) | nF/km | 55 |
| Operating Voltage | V | 750 |
Minimum Bending Radius : 8×OD (static) ; 16×OD (dynamic)
Temperature Range : -40℃ to +70℃ (during operation) ; -20℃ to +50℃ (during installation)
| Cable Code | No. of Pairs | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | |
|---|---|---|---|---|---|
| Inner | Outer | ||||
| mm | mm | mm | kg/km | ||
| 1.13mm Conductor, 2.3 Insulated Wire | |||||
| BRAIL ZPGU-2Y2Y(L)Y-1P1S | 1 | 1.0 | 1.5 | 9.8 | 95 |
| BRAIL ZPGU-2Y2Y(L)Y-2P1S | 2 | 1.0 | 1.5 | 10.6 | 130 |
| BRAIL ZPGU-2Y2Y(L)Y-3P1S | 3 | 1.0 | 1.5 | 13.2 | 179 |
| BRAIL ZPGU-2Y2Y(L)Y-7P1S | 7 | 1.0 | 1.7 | 18.3 | 301 |
| BRAIL ZPGU-2Y2Y(L)Y-14P1S | 14 | 1.2 | 1.8 | 21.3 | 532 |
1.0 mm² solid copper conductors with a nominal diameter of 1.13 mm.
One, two, three, seven and fourteen-pair arrangements in the dimension schedule.
Tape screening with a dedicated drain wire and PVC or LSZH sheath options.
Select the pair count from the circuit schedule and identify the sheath material for the installation. Coordinate screen continuity and drain-wire termination with the equipment design. Use the listed overall diameter for entries and supports, and the 8 times static or 16 times dynamic bend-radius figures when planning the route.
ZCO3 & ZCO3-SH Quad Railway Signalling Cable for High-Speed Lines
K24 LSZH Subway Signalling Cable, Armoured and Unarmoured Options
Is ZPGU a solid or stranded conductor cable?
The listed construction uses class 1 solid copper conductors.
Which conductor size is specified?
The nominal cross-section is 1.0 mm², with a nominal conductor diameter of 1.13 mm.
Does ZPGU include steel tape armour?
This construction lists a tape screen and drain wire, without a steel tape armour layer.
What sheath options are listed?
PVC and LSZH outer sheath options are listed. Include the required material in the order.
What should accompany a local-circuit cable enquiry?
Provide pair count, route length, sheath choice, equipment-entry size and the screen-termination requirements.