H05V2V2H2-F Flat Heat Resistant Appliance Cable, 300/500V
Flat H05V2V2H2-F heat-resistant PVC cable for indoor appliance connections. TI3 insulation and a TM3 sheath surround flexible copper conductors; round H05V2V2-F alternatives are included in the range table.
H05V2V2-F H05V2V2H2-F.pdf Contact us

APPLICATION AND DESCRIPTION

The flat H05V2V2H2-F construction serves indoor appliance connections where the equipment calls for a flat, heat-resistant flexible cord. It combines fine-stranded copper conductors with TI3 PVC insulation and a TM3 PVC sheath. The rated voltage is 300/500V, with a maximum normal conductor temperature of 90°C. The range table also includes round H05V2V2-F alternatives for equipment with a different cord-entry arrangement.

STANDARD AND APPROVAL

  • CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1

CABLE CONSTRUCTION

Technical Characteristics

Bare copper fine wire conductor
Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383
PVC core insulation TI3 to VDE-0281 Part 1
Green-yellow grounding (3 conductors and above)
Color coded to VDE-0293-308
PVC outer jacket TM3

 

Working voltage300/500 volts
Test voltage2000 volts
Flexing bending radius15 x O
Static bending radius4 x O
Flexing temperature+5o C to +90o C
Static temperature-40o C to +90o C
Short circuit temperature+160o C
Flame retardantIEC 60332.1
Insulation resistance20 MΩ x km

CABLE PARAMETER

AWGNo. of Cores x Nominal Cross Sectional AreaNominal Thickness of InsulationNominal Thickness of SheathNominal Overall DiameterNominal Copper WeightNominal Weight

# x mm^2mmmmmmkg/kmkg/km
H05V2V2-F
18(24/32)2 x 0.750.60.86.214.454.2
18(24/32)3 x 0.750.60.86.621.665
18(24/32)4 x 0.750.60.87.12977.7
18(24/32)5 x 0.750.60.983697.3
17(32/32)2 x 1.000.60.86.41960.5
17(32/32)3 x 1.000.60.86.82973.1
17(32/32)4 x 1.000.60.97.63893
17(32/32)5 x 1.000.60.98.348111.7
16(30/30)2 x 1.500.70.87.42982.3
16(30/30)3 x 1.500.70.98.143104.4
16(30/30)4 x 1.500.71.0958131.7
16(30/30)5 x 1.500.71.11072163.1
14(50/30)2 x 2.500.81.09.248129.1
14(50/30)3 x 2.500.81.11072163
14(50/30)4 x 2.500.81.110.996199.6
14(50/30)5 x 2.500.81.212.4120245.4
12(56/28)3 x 4.000.81.211.3115224
12(56/28)4 x 4.000.81.212.5154295
12(56/28)5 x 4.000.81.413.7192361
10(84/28)3 x 6.000.81.113.1181328
10(84/28)4 x 6.000.81.313.9230490
H05V2V2H2-F
18(24/32)2 x 0.750.60.84.2 x 6.814.148
17(32/32)2 x 1.000.60.84.4 x 7.21957


KEY FEATURES

  • Flat profile identified by the H2 designation.

  • Flexible class 5 copper with heat-resistant PVC insulation and sheath.

  • Round alternatives retained in the same range table for comparison.

SELECTION NOTES

Use both overall dimensions when checking the flat cable against a cord grip or cable passage. Confirm the required protective conductor and terminal layout against the appliance design. Avoid sharp folds across the flat profile and route away from hot parts; a heat-resistant compound still requires a suitable installation.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Which model is the flat cable?

H05V2V2H2-F is the flat construction. H05V2V2-F is the round alternative.

Why does the table also list round cables?

It covers the complete H05V2V2 range. Select the rows under the flat-cable designation when ordering H05V2V2H2-F.

Can a flat cord replace a round one solely because the voltage matches?

The equipment entry, cord grip, conductor arrangement and termination must also suit the selected construction.

What does the 90°C limit apply to?

The conductor during normal operation. Cable loading and surrounding temperature must be assessed together.

What details should accompany a flat-cord enquiry?

State H05V2V2H2-F, conductor area, core arrangement, overall dimensions required by the appliance, colour and finished length.