A-2Y2YB2Y S(H115)/S(H145)/S(H95)
APPLICATIONThe cables are designed in railways signalling networks, and are suitable for installation in ducts or laying directly into the ground.STANDARDDlk 1.013.107yDlk 1.013.108y (for 1.4/1.8mm conductor H95 type)Dlk 1.013.110yCABLE CONSTRUCTIONTy…
A-2Y2YB2YS(H115) S(H145) (H95).pdf Contact us

APPLICATION

The cables are designed in railways signalling networks, and are suitable for installation in ducts or laying directly into the ground.

STANDARD

  • Dlk 1.013.107y

  • Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)

  • Dlk 1.013.110y

CABLE CONSTRUCTION

  • Type CodesConductors: Solid annealed copper, 0.9, 1.4 or 1.8 mm nominal diameter.

  • Insulation: Solid polyethylene.

  • Stranding: Single conductors are helically stranded in concentric layers. Cables from 14 conductors on have two extra conductors of 0.5mm with perforated insulation (surveillance conductors).

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Inner Sheath: Low density polyethylene.

  • Armouring: One layer of galvanized steel tape (0.2-0.3mm) or two layers of galvanized steel tapes (0.1mm).

  • Outer Sheath: Low density polyethylene.

  • AJ- outdoor cable with protection against inductive infl uences

  • 2Y solid PE conductor insulation

  • 2Y inner PE sheath

  • B steel tape armor

  • 2Y outer PE sheath

  • S signal cable

  • LG layer stranding

  • H (n) operating capacity

ELECTRICAL CHARACTERISTICS AT 20℃

Nominal Conductor Diametermm0.91.41.8
Maximum Conductor ResistanceΩ/km28.911.97.2
Minimum Insulation Resistance @500 V DC (1min)MΩ.km100001000010000
Maximum Conductor Capacitance @800Hz (AC)nF/km115145/95*145/95*
Dielectric Strength, conductor to conductor (DC voltage 1min)V353535353535
Surveillance Conductors



Loop resistance, maximumΩ/km190190190
Insulation resistance



- dry cable core, minimumMΩ.km100010001000
- wet cable core, maximumKΩ.km303030
Operating Voltage AC/DCV420/600420/600420/600
Test Voltage@50 Hz 1 min



Core to CoreVeff250025002500
Core to ScreenVeff250025002500

*The value“ 95” is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 10×OD

  • Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

DIMENSIONS AND WEIGHT

A-2Y2YB2Y n×1× 0.9 S(H115)

Cable CodeNumber of
conductors
(n)
Nominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
InnerOuter
0.9mm Conductor, 1.55mm Insulated Wire
RS107y-2Y2YB2Y-2C0.9-S(H115)21.31.212.0120
RS107y-2Y2YB2Y-4C0.9-S(H115)41.31.213.0140
RS107y-2Y2YB2Y-7C0.9-S(H115)71.31.214.0170
RS107y-2Y2YB2Y-10C0.9-S(H115)101.31.215.5220
RS107y-2Y2YB2Y-14C0.9-S(H115)141.31.216.0260
RS107y-2Y2YB2Y-20C0.9-S(H115)201.31.217.0320
RS107y-2Y2YB2Y-24C0.9-S(H115)241.31.219.0370
RS107y-2Y2YB2Y-30C0.9-S(H115)301.31.219.0410
RS107y-2Y2YB2Y-40C0.9-S(H115)401.31.220.0500
RS107y-2Y2YB2Y-50C0.9-S(H115)501.31.222.0590
RS107y-2Y2YB2Y-60C0.9-S(H115)601.31.223.0680
RS107y-2Y2YB2Y-80C0.9-S(H115)801.31.225.0840
RS107y-2Y2YB2Y-100C0.9-S(H115)1001.31.328.01020
RS107y-2Y2YB2Y-120C0.9-S(H115)1201.31.329.01180
RS107y-2Y2YB2Y-140C0.9-S(H115)1401.31.331.01360

A-2Y2YB2Y n×1×1.4/1.8 S(H145)

Cable CodeNumber of
conductors
(n)
Nominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
InnerOuter
1.4mm Conductor, 2.2mm Insulated Wire
BR107y-2Y2YB2Y-4C1.4-S(H145)41.31.214.0190
BR107y-2Y2YB2Y-7C1.4-S(H145)71.31.215.5260
BR107y-2Y2YB2Y-10C1.4-S(H145)101.31.218.0340
BR107y-2Y2YB2Y-14C1.4-S(H145)141.31.219.0420
BR107y-2Y2YB2Y-20C1.4-S(H145)201.31.221.0550
BR107y-2Y2YB2Y-24C1.4-S(H145)241.31.222.0630
BR107y-2Y2YB2Y-30C1.4-S(H145)301.31.223.0750
BR107y-2Y2YB2Y-40C1.4-S(H145)401.31.225.0940
BR107y-2Y2YB2Y-50C1.4-S(H145)501.31.328.01140
BR107y-2Y2YB2Y-60C1.4-S(H145)601.31.330.01320
1.8mm Conductor, 2.7mm Insulated Wire
BR107y-2Y2YB2Y-4C1.8-S(H145)41.31.215.5250
BR107y-2Y2YB2Y-7C1.8-S(H145)71.31.217.0350
BR107y-2Y2YB2Y-10C1.8-S(H145)101.31.220.0470
BR107y-2Y2YB2Y-14C1.8-S(H145)141.31.221.0600
BR107y-2Y2YB2Y-20C1.8-S(H145)201.31.224.0800
BR107y-2Y2YB2Y-24C1.8-S(H145)241.31.226.0910
BR107y-2Y2YB2Y-30C1.8-S(H145)301.31.227.01100
BR107y-2Y2YB2Y-40C1.8-S(H145)401.31.230.01400

A-2Y2YB2Y n×1×1.4 S(H95)

Cable CodeNumber of
conductors
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1.4mm Conductor, 2.7mm Insulated Wire
BR108y-2Y2Yv-10C1.4-S(H95)102.016.0270
BR108y-2Y2Yv-14C1.4-S(H95)142.018.0350
BR108y-2Y2Yv-20C1.4-S(H95)202.020.0470
BR108y-2Y2Yv-30C1.4-S(H95)302.224.0670
BR108y-2Y2Yv-50C1.4-S(H95)502.229.01050
1.8mm Conductor, 3.4mm Insulated Wire

BR108y-2Y2Yv-10C1.8-S(H95)

102.019.0400
BR108y-2Y2Yv-14C1.8-S(H95)142.221.0540
BR108y-2Y2Yv-20C1.8-S(H95)202.224.0730
BR108y-2Y2Yv-30C1.8-S(H95)302.228.01050
BR108y-2Y2Yv-50C1.8-S(H95)502.236.01700