TYPE C1 & C2 Railway Signalling Cable
APPLICATIONThe cables are designed for railway signalling systems. The cables are suitable for use in d.c. circuits where the nominal voltage to earth does not exceed 1100 volts and are suitable for installation in ducts.STANDARDNR/PS/SIG/00005(former…
TYPE C1 & C2 Railway Signalling Cable.pdf Contact us

APPLICATION

The cables are designed for railway signalling systems. The cables are suitable for use in d.c. circuits where the nominal voltage to earth does not exceed 1100 volts and are suitable for installation in ducts.

STANDARD

  • NR/PS/SIG/00005(formerly RT/E/PS/00005)

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Tinned stranded copper, class 5 according to IEC 60228 & BS 6360.

  • Insulation: EPR Type GP4 to BS 7655.

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Sheath: HDPCP Type RS2 to BS 7655.

Nominal Conductor Cross Sectionmm2.5
Maximum DC Conductor ResistanceΩ/km8.21
Voltage RatingKV0.65/1.1
Nominal Insulation Thicknessmm1.05

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 6×OD (static); 15×OD (dynamic)

  • Temperature Range: -25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of cores& Nominal
Conductor Cross Sectional
Area
No.×mm
No. & Nominal
Diameter of Strands
No/mm
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
Type C1
BRAIL C1-3G5G-1G2.51×2.550/0.253.811.2/14.0195
Type C2
BRAIL C2-3G5G-2G2.52×2.550/0.253.814.9/18.8370
BRAIL C2-3G5G-4G2.54×2.550/0.253.816.4/20.9460
BRAIL C2-3G5G-7G2.57×2.550/0.253.818.7/23.7610
BRAIL C2-3G5G-10G2.510×2.550/0.253.822.5/28.6920
BRAIL C2-3G5G-12G2.512×2.550/0.253.823.2/29.3950
BRAIL C2-3G5G-16G2.516×2.550/0.253.825.3/32.01180

Routine test voltage: 2.5kV for 5 minutes