EUROBALISE BGA
APPLICATIONThe cables are used as balise cables for ERTMS (European Rail Traffic Management System) railway networks. The cables are armoured and can provide low reduction factor.STANDARDCEI 20-11CEI 20-14CEI 20-29CEI 20-34CEI 46-4CEI 103-10CABLE CONS…
EUROBALISE BGA.pdf Contact us

APPLICATION

The cables are used as balise cables for ERTMS (European Rail Traffic Management System) railway networks. The cables are armoured and can provide low reduction factor.

STANDARD

  • CEI 20-11

  • CEI 20-14

  • CEI 20-29

  • CEI 20-34

  • CEI 46-4

  • CEI 103-10

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Solid annealed copper, 1.6 mm nominal diameter.

  • Insulation: Solid polyethylene.

  • Stranding: Conductors will be stranded with dielectric fi llers in order to get a circular core shape.

  • Core Wrapping: Plastic tape (s) with overlapping.

  • Inner Sheath: Low density polyethylene.

  • Screen: Aluminium/polyethylene tape longitudinally applied and overlapped.

  • Drain Wire: Tinned copper drain wire

  • Intermediate Sheath: Low density polyethylene.

  • Armour: Two galvanized steel tapes.

  • Outer Sheath: Low density polyethylene.

Nominal Conductor Diametermm1.6
Maximum Conductor Resistance (DC)Ω/km21.5
Mutual CapacitancenF/km42.3+/-15%
Nominal Characteristic Impedance @8.9 KHzΩ130
Nominal Characteristic Impedance @560 KHzΩ110
Maximum Attenuation @560 KHzdB/km3.8
Insulation ResistanceMΩ.km10000
Minimum Dielectric Strength core to screen (DC)V1000
Minimum Dielectric Strength core to core (DC)V3000
Reduction Factor @100V/km 50Hz
0.6

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 8×OD (static); 16×OD (dynamic)

  • Temperature Range: -30℃ to +70℃ (during operation); -20℃ to +50℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNumber of PairsNominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
InnerInter.Outer
1.6mm Conductor, 3.4mm Insulated Wire
BRAIL BGA-2Y2Y(L)2YB2Y-1P1.611.00.81.616334