APPLICATIONThe cables are telecommunication cables for tunnel application. The cables are halogen free fi re resistant, inductive protected and armoured.STANDARDFire retardant: NBN C 30-004 F2Fire resistant: NBN 713-020 Add.3. -RF 1hCABLE CONSTRUCTION…
MD4 Fire Resisting TelecomCables (CR1-C1 Class).pdf Contact us

APPLICATION

The cables are telecommunication cables for tunnel application. The cables are halogen free fi re resistant, inductive protected and armoured.

STANDARD

  • Fire retardant: NBN C 30-004 F2

  • Fire resistant: NBN 713-020 Add.3. -RF 1h

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Solid copper conductor, 0.5mm nominal cross section area.

  • Insulation: Mica-tape + LSZH insulation.

  • Cabling Element: Four conductors are twisted to form a quad.

  • Stranding: Quads are helically stranded in concentric layers.

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Inner Sheath: LSZH sheath.

  • Screen: Copper tape screen.

  • Intermediate Sheath: LSZH sheath.

  • Armour: Two layer of steel tape.

  • Outer Sheath: LSZH sheath.

Nominal Conductor Diametermm0.8
Nominal Cross Section Areamm0.5
Nominal Insulation Thicknessmm0.5
Maximum Conductor Resistance (DC)Ω/km36.7
Minimum Insulation ResistanceMΩ.km100
Maximum CapacitancenF/km120
Voltage Test 2 minsKVac0.5

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 10×OD

  • Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of
Quads
Nominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
InnerInter.Outer
0.8mm Conductor, 1.8mm Insulated Wire
BRAIL MD4-HH(K)HBH-7Q0.8-FR71.01.01.830.71074