ST2513/CT2243 Outdoor Single Mode Unarmoured Trackside Optical Fiber Cables
APPLICATIONThe cables are designed for long distance telecom links on optical fibres along railway tracks. The cables are suitable for pulled through ducts or laid in channels.STANDARDSNCF ST 2513-99CABLE CONSTRUCTIONElectrical Characteristics at 20℃…
ST2513_CT2243 Outdoor Single Mode Unarmoured Trackside Optical Fiber Cables.pdf Contact us

APPLICATION

The cables are designed for long distance telecom links on optical fibres along railway tracks. The cables are suitable for pulled through ducts or laid in channels.

STANDARD

  • SNCF ST 2513-99

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Fibres: Singlemode optical fibres G652 coloured (6 or 12 per tube).

  • Tube: PBT polyester tubes From 12 to 72 OFs: 1 to 6 tubes; 144 OFs: 12 tubes.

  • Central Strength Member: Non-metallic central reinforcement (FRP).

  • Filling: Petroleum jelly + water-swelling yarns.

  • Reinforcement: Water-swelling aramid fi bres.

  • Sheath: PE sheath.

Maximum Attenuation
G652
@1310nmdB/km0.35
@1550nmdB/km0.22
Maximum Chromatic Dispersion

Between 1260 and 1360nmps/(nm/km)3.5
Between 1530 and 1565nmps/(nm/km)19
Zero Dispersion Wavelengthnm1310±11
Zero Dispersion Slopeps/(nm2.km)0.09
Numerical Aperture
0.14
Point discontinuitydB0.1
PMD (individual fi ber)ps/km0.2
Maximum Cutoff Wavelengthnm1260
Cladding Diameterum125±1
Core/Cladding Concentricity Errorum≤0.5
Cladding Non Circularity%≤1
Coating Non Circularity%≤6
Proof Test LevelKpsi (GN/m2)100 (0.7)
Crush ResistanceN/cm300
Maximum Laying TensionNFrom 12 to 72 FO: 2500;144 FO: 3000

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: from 12 to 72 FO: 230mm; 144 FO: 340mm.

  • Temperature Range: -30℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of fi bresNo of Tubes x No
of Fibers/Tube
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
BROB3-ML-B-9-1×12-F-2Y121 tubes of 12 OF1.511.6112
BROB3-ML-B-9-3×12-F-2Y363 tubes of 12 OF1.511.6112
BROB3-ML-B-9-6×6-F-2Y366 tubes of 6 OF1.511.6112
BROB3-ML-B-9-6×12-F-2Y726 tubes of 12 OF1.511.6112
BROB3-ML-B-9-12×12-F-2Y14412 tubes of 12 OF1.517.0225