EEMUA 133 lead covered armoured power cable
1900/3300V is designed for fixed
power distribution in demanding
industrial environments.
It is suitable for petrochemical plants,
oil refineries, chemical facilities,
industrial plants, power stations,
utility networks and infrastructure projects.
The cable is commonly used where
additional protection against hydrocarbons,
oil, moisture, solvents and corrosive
environments is required.
The XLPE insulation provides reliable
electrical performance and thermal stability
for 3.3kV power distribution systems.
The lead covering provides enhanced
protection against aromatic hydrocarbons,
solvent penetration and corrosive attack.
The PVC bedding and PVC outer sheath
provide general protection against moisture,
abrasion and normal installation conditions.
The armoured construction provides
mechanical protection for fixed
installation routes.
This cable is suitable for installation
on cable trays, in cable ducts,
in trenches, underground and in
industrial cable routes.
It is commonly selected for petrochemical
and refinery projects where mechanical
protection and environmental resistance
are both required.
The cable should be selected according to
voltage rating, number of cores,
conductor size, lead sheath requirement,
armour type, installation method
and project specification.
| Conductor | Annealed Copper conductor, circular or shaped, Class 2 to BS EN60228. |
| Insulation | XLPE (Cross-Linked Polyethylene) Type GP 8 conforming to BS 7655-1.3 or type GP 6 conforming to BS 7655-1.2. |
| Colour Code | 3 Cores : Brown, Black, Grey |
| Bedding | PVC (Polyvinyl Chloride) |
| Protection | LC (Lead alloy 'E') sheathed |
| Inner Sheath | PVC (Polyvinyl Chloride) |
| Armour | Multi Core : GSWA (Galvanized Steel Wire Armour) |
| Outer Sheath | PVC(Polyvinyl Chloride), or anti-rodent and anti-termite PVC(optional) |
| Voltage rating | 1900/3300V |
| Temperature rating | 0°C to +90°C |
| Bending radius | 12 x overall diameter |
| Flame retardant | BS EN 60332-1-2 |
| Nominal Cross-sectional Area | Strand Type | Nominal Insulation thickness | Nominal Lead sheath thickness | Nominal Inner Sheath thickness | Nominal Steel Wire Armor dia. | Nominal Outer Sheath thickness | Approx. Overall Diameter | Aprrox Weight |
|---|---|---|---|---|---|---|---|---|
| mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km |
| 3x16 | 7/1.70 | 2 | 1.3 | 1 | 1.6 | 1.8 | 31.8 | 2750 |
| 3x25 | 7/2.14 | 2 | 1.4 | 1 | 1.6 | 1.8 | 34.9 | 3412 |
| 3x35 | 7/2.52 | 2 | 1.5 | 1 | 1.6 | 1.9 | 37.6 | 4045 |
| 3x50* | 19/1.78 | 2 | 1.5 | 1.2 | 2 | 2 | 40.2 | 4822 |
| 3x70* | 19/2.14 | 2 | 1.5 | 1.2 | 2 | 2.1 | 41.7 | 5560 |
| 3x95* | 19/2.52 | 2 | 1.6 | 1.2 | 2 | 2.2 | 43.5 | 6582 |
| 3x120* | 37/2.03 | 2 | 1.7 | 1.4 | 2.5 | 2.3 | 50.4 | 8440 |
| 3x150* | 37/2.25 | 2 | 1.8 | 1.4 | 2.5 | 2.4 | 52.7 | 9540 |
| 3x185* | 37/2.52 | 2 | 1.9 | 1.4 | 2.5 | 2.5 | 56.6 | 11272 |
| 3x240* | 61/2.25 | 2 | 2 | 1.6 | 2.5 | 2.6 | 62.3 | 13819 |
| 3x300* | 61/2.52 | 2 | 2.2 | 1.6 | 2.5 | 2.7 | 66.9 | 16456 |
| 3x400* | 61/2.85 | 2 | 2.3 | 1.6 | 2.5 | 2.9 | 71.4 | 20900 |
* Shaped stranded conductor
KEY FEATURES
- Designed according to EEMUA 133 requirements
- 1900/3300V voltage rating
- Basic design based on BS5467 cable construction
- XLPE insulated conductors
- Lead covered cable construction
- PVC bedding and PVC outer sheath
- Armoured cable construction
- Suitable for fixed 3.3kV power distribution
- Enhanced resistance to hydrocarbons and solvents
- Suitable for petrochemical and refinery projects
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Number of cores
- Conductor size
- Conductor material
- Cable length
- Lead sheath requirement
- Armour type
- Sheath colour
- Installation method
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
EEMUA 133 lead covered armoured cable
1900/3300V is commonly selected for
petrochemical, refinery and industrial projects
where hydrocarbon resistance, solvent protection
and mechanical protection are required.
The lead covering provides additional
environmental protection compared with
standard PVC sheathed armoured power cables.
If low smoke zero halogen performance
is required, a different cable construction
should be confirmed according to
project specification.
RELATED CABLE TYPES
- EEMUA 133 cable
- Lead covered power cable
- BS5467 armoured power cable
- BS5467 1900/3300V cable
- BS6724 LSZH armoured cable
- BS7846 fire resistant cable
- IEC 60502 power cable
- XLPE insulated power cable
- PVC sheathed power cable
- Petrochemical power cable
FAQ
What is EEMUA 133 lead covered cable used for?
It is used for fixed power distribution
in petrochemical plants, oil refineries,
chemical facilities, industrial plants
and harsh environments.
What is the voltage rating of this cable?
This page is for EEMUA 133 lead covered
armoured power cable rated 1900/3300V.
What is the benefit of lead covering?
The lead covering provides enhanced
protection against hydrocarbons,
oil, solvents, moisture and corrosive attack.
It is useful in demanding industrial,
chemical and petrochemical environments.
Is this cable the same as standard BS5467 cable?
No. It is based on armoured power cable
construction, but includes a lead covering
for additional environmental protection.
Standard BS5467 cable normally does not
include a lead sheath.
Is this cable LSZH?
No. This page focuses on PVC sheathed
lead covered armoured cable.
If LSZH performance is required,
the cable construction should be confirmed
separately according to project requirements.
Is this cable fire resistant?
This cable may have flame retardant
performance according to relevant
fire test requirements.
It should not be described as a
BS6387 circuit integrity fire resistant cable
unless mica tape and circuit integrity
performance are specified.
Is this cable suitable for refineries?
Yes. EEMUA 133 lead covered cable
is commonly used in refineries,
petrochemical plants and chemical facilities
where hydrocarbon and chemical protection
are required.
Can this cable be used underground?
Yes. It can be used in underground routes,
ducts, trenches and industrial cable routes,
subject to project specification
and local installation requirements.
What information is required for quotation?
Please confirm voltage rating,
number of cores, conductor size,
conductor material, lead sheath requirement,
armour type and cable length.
Installation method, sheath colour,
standard and destination port
are also required.
Can BURYCABLE supply EEMUA 133
lead covered armoured cable?
Yes. BURYCABLE can supply EEMUA 133
lead covered armoured power cables
according to project voltage, core number,
conductor size, armour type, lead sheath
requirement, length and packing requirements.