600/1000V single core XLPE insulated
PVC sheathed armoured cable to BS5467
is designed for fixed low voltage
power distribution.
It is suitable for commercial buildings,
industrial plants, infrastructure projects,
utility installations and outdoor power systems.
The cable can be installed on cable trays,
in ducts, in trenches, underground
and in protected direct burial routes,
subject to project specification
and local installation requirements.
The XLPE insulation provides reliable
electrical performance and thermal stability.
The PVC outer sheath provides general
protection against moisture, abrasion
and normal installation conditions.
For single core AC systems,
aluminium wire armour is commonly used
to reduce magnetic losses.
The armoured construction provides
mechanical protection for demanding
fixed installation routes.
This cable is commonly used for power
circuits where mechanical protection
and stable power supply are required.
It should not be described as a BS6387
fire resistant circuit integrity cable
unless mica tape and circuit integrity
performance are specified.
The cable should be selected according to
voltage rating, conductor size,
conductor material, armour type,
installation method and project specification.
Basic design to to BS 5467
| Flame Retardance (Single Vertical Wire Test) | BS EN 60332-1-2 |
600/1000V
| Conductor | Annealed copper wire, stranded according to BS EN 60228 class 2. |
| Insulation | Extruded XLPE GP 8 according to BS 7655-1.3. |
| Bedding | PVC or polymeric compound. |
| Armouring | Aluminium wire |
| Outer Sheath | PVC Type 9 according to BS 7655-4.2. |
| Outer Sheath Option | UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. |
| Insulation Colour | Brown or blue |
| Sheath Colour | Black, other colours can be offered upon request. |
| Maximum temperature range during operation (XLPE) | 90°C |
| Maximum short circuit temperature (5 Seconds) | 250°C |
| Minimum bending radius | 8 x Overall Diameter |
| Conductor | FLP600-RVMAV-R | ||||||
|---|---|---|---|---|---|---|---|
| No. of Cores xCross Section | Class of Conductor | Nominal Insulation Thickness | Nominal Bedding Thickness | Nominal Armour Wire Diameter | Nominal Sheath Thickness | Approx. Overall Diameter | Approx. Weight |
| No.xmm² | mm | mm | mm | mm | mm | kg/km | |
| 1x50 | 2 | 1.0 | 0.8 | 0.9 | 1.5 | 17.5 | 800 |
| 1x70 | 2 | 1.1 | 0.8 | 1.25 | 1.5 | 20.2 | 990 |
| 1x95 | 2 | 1.1 | 0.8 | 1.25 | 1.6 | 22.3 | 1280 |
| 1x120 | 2 | 1.2 | 0.8 | 1.25 | 1.6 | 24.2 | 1550 |
| 1x150 | 2 | 1.4 | 1.0 | 1.6 | 1.7 | 27.4 | 1900 |
| 1x185 | 2 | 1.6 | 1.0 | 1.6 | 1.8 | 30 | 2320 |
| 1x240 | 2 | 1.7 | 1.0 | 1.6 | 1.8 | 32.8 | 2930 |
| 1x300 | 2 | 1.8 | 1.0 | 1.6 | 1.9 | 35.6 | 3580 |
| 1x400 | 2 | 2.0 | 1.2 | 2.0 | 2.0 | 40.5 | 4600 |
| 1x500 | 2 | 2.2 | 1.2 | 2.0 | 2.1 | 44.2 | 5680 |
| 1x630 | 2 | 2.4 | 1.2 | 2.0 | 2.2 | 48.8 | 7160 |
| 1x800 | 2 | 2.6 | 1.4 | 2.5 | 2.4 | 55.4 | 9315 |
| 1x1000 | 2 | 2.8 | 1.4 | 2.5 | 2.5 | 60.6 | 11490 |
| Conductor Operating Temperature | 90°C |
| Ambient Temperature | 30°C |
| Conductor cross-sectional area | Reference Method C (clipped direct) | Reference Method F (in free air or on a perforated cable tray, horizontal or vertical) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Touching | Touching | Spaced by on cable diameter | |||||||||
| 2 cables, single-phase a.c. or d.c. flat | 3 or 4 cables, three-phase a.c. flat | 2 cables, single-hase a.c. or d.c. flat | 3 or 4 cables, three-phase a.c. flat | 3 cables three-phase a.c. trefoil | 2 cables, d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, three-phase a.c. | ||||
| Horizontal | Vertical | Horizontal | Vertical | Horizontal | Vertical | ||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| mm2 | A | A | A | A | A | A | A | A | A | A | A |
| 50 | 237 | 220 | 253 | 232 | 222 | 284 | 270 | 282 | 266 | 288 | 266 |
| 70 | 303 | 277 | 322 | 293 | 285 | 356 | 349 | 357 | 337 | 358 | 331 |
| 95 | 367 | 333 | 389 | 352 | 346 | 446 | 426 | 436 | 412 | 425 | 393 |
| 120 | 425 | 383 | 449 | 405 | 402 | 519 | 497 | 504 | 477 | 485 | 449 |
| 150 | 488 | 437 | 516 | 462 | 463 | 600 | 575 | 566 | 539 | 549 | 510 |
| 185 | 557 | 496 | 587 | 524 | 529 | 688 | 660 | 643 | 614 | 618 | 574 |
| 240 | 656 | 579 | 689 | 612 | 625 | 815 | 782 | 749 | 714 | 715 | 666 |
| 300 | 755 | 662 | 792 | 700 | 720 | 943 | 906 | 842 | 805 | 810 | 755 |
| 400 | 853 | 717 | 899 | 767 | 815 | 1137 | 1094 | 929 | 889 | 848 | 797 |
| 500 | 962 | 791 | 1016 | 851 | 918 | 1314 | 1266 | 1032 | 989 | 923 | 871 |
| 630 | 1082 | 861 | 1146 | 935 | 1027 | 1528 | 1474 | 1139 | 1092 | 992 | 940 |
| 800 | 1170 | 904 | 1246 | 987 | 1119 | 1809 | 1744 | 1204 | 1155 | 1042 | 978 |
| 1000 | 1261 | 961 | 1345 | 1055 | 1214 | 2100 | 2026 | 1289 | 1238 | 1110 | 1041 |
| Nominal Cross Section Area | 2 cables d.c. | Ref. Methods C&F(clipped direct, on trays or in free air) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 cables, single-phase a.c. | 3 or 4 cables, three-phase a.c. | |||||||||||||||
| Touching | Spaced* | Trefoil and touching | Flat and touching | Flat and spaced* | ||||||||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | ||||||||||
| mm2 | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||||||||
| r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
| 50 | 0.98 | 0.99 | 0.21 | 1.0 | 0.98 | 0.29 | 1.0 | 0.86 | 0.18 | 0.87 | 0.64 | 0.25 | 0.88 | 0.84 | 0.33 | 0.9 |
| 70 | 0.67 | 0.68 | 0.20 | 0.71 | 0.69 | 0.29 | 0.75 | 0.59 | 0.170 | 0.62 | 0.60 | 0.25 | 0.65 | 0.62 | 0.32 | 0.70 |
| 95 | 0.49 | 0.51 | 0.195 | 0.55 | 0.53 | 0.28 | 0.60 | 0.44 | 0.170 | 0.47 | 0.46 | 0.24 | 0.52 | 0.49 | 0.31 | 0.58 |
| 120 | 0.39 | 0.41 | 0.190 | 0.45 | 0.43 | 0.27 | 0.51 | 0.35 | 0.165 | 0.39 | 0.38 | 0.24 | 0.44 | 0.41 | 0.30 | 0.51 |
| 150 | 0.31 | 0.33 | 0.185 | 0.38 | 0.36 | 0.27 | 0.45 | 0.29 | 0.160 | 0.33 | 0.31 | 0.23 | 0.39 | 0.34 | 0.29 | 0.45 |
| 185 | 0.25 | 0.27 | 0.185 | 0.33 | 0.30 | 0.26 | 0.40 | 0.23 | 0.160 | 0.28 | 0.26 | 0.23 | 0.34 | 0.29 | 0.29 | 0.41 |
| 240 | 0.195 | 0.21 | 0.180 | 0.28 | 0.24 | 0.26 | 0.35 | 0.180 | 0.155 | 0.24 | 0.21 | 0.22 | 0.30 | 0.24 | 0.28 | 0.37 |
| 300 | 0.155 | 0.17 | 0.175 | 0.25 | 0.195 | 0.25 | 0.32 | 0.145 | 0.150 | 0.21 | 0.170 | 0.22 | 0.28 | 0.20 | 0.27 | 0.34 |
| 400 | 0.115 | 0.145 | 0.170 | 0.22 | 0.180 | 0.24 | 0.30 | 0.125 | 0.150 | 0.195 | 0.160 | 0.21 | 0.27 | 0.20 | 0.27 | 0.33 |
| 500 | 0.093 | 0.125 | 0.170 | 0.21 | 0.165 | 0.24 | 0.29 | 0.105 | 0.145 | 0.180 | 0.145 | 0.20 | 0.25 | 0.190 | 0.24 | 0.31 |
| 630 | 0.073 | 0.105 | 0.165 | 0.195 | 0.150 | 0.23 | 0.27 | 0.092 | 0.145 | 0.170 | 0.135 | 0.195 | 0.24 | 0.175 | 0.23 | 0.29 |
| 800 | 0.056 | 0.090 | 0.160 | 0.190 | 0.145 | 0.23 | 0.27 | 0.086 | 0.140 | 0.165 | 0.130 | 0.180 | 0.23 | 0.175 | 0.195 | 0.26 |
| 1000 | 0.045 | 0.092 | 0.155 | 0.180 | 0.140 | 0.21 | 0.25 | 0.080 | 0.135 | 0.155 | 0.125 | 0.170 | 0.21 | 0.165 | 0.180 | 0.24 |
Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance
KEY FEATURES
- Designed according to BS5467 requirements
- 600/1000V voltage rating
- Single core cable construction
- XLPE insulated conductor
- PVC outer sheath
- Armoured cable construction
- Aluminium wire armour commonly used for single core AC circuits
- Suitable for fixed low voltage power distribution
- Suitable for outdoor and underground installation
- Suitable for ducts, trenches and protected cable routes
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Conductor size
- Conductor material
- Cable length
- Armour type
- Sheath colour
- Installation method
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
BS5467 single core XLPE insulated
PVC sheathed armoured cable is commonly
selected for low voltage power distribution
where mechanical protection and fixed
installation are required.
For single core AC circuits,
non-magnetic armour such as AWA
is normally recommended.
If low smoke zero halogen sheath
performance is required, BS6724 cable
is usually selected instead.
RELATED CABLE TYPES
- BS5467 armoured power cable
- BS5467 multicore cable
- BS5467 1900/3300V cable
- BS6724 LSZH armoured cable
- BS7211 cable
- IEC 60502-1 low voltage cable
- XLPE insulated power cable
- PVC sheathed power cable
- AWA cable
- Underground power cable
FAQ
What is this BS5467 single core cable used for?
This cable is used for fixed low voltage
power distribution.
It is suitable for buildings,
industrial plants, infrastructure projects,
outdoor routes, ducts, trenches
and underground installations.
What is the voltage rating of this cable?
This page is for 600/1000V
single core XLPE insulated PVC sheathed
armoured cable to BS5467.
Is this cable LSZH?
No. BS5467 cable normally uses
a PVC outer sheath.
If LSZH performance is required,
BS6724 cable is usually selected instead.
Is this cable fire resistant?
BS5467 cable has flame retardant
performance according to relevant
fire test requirements.
It should not be described as a
BS6387 circuit integrity fire resistant cable
unless mica tape and circuit integrity
performance are specified.
Is this cable armoured?
Yes. This page is for single core
armoured BS5467 cable.
For single core AC systems,
aluminium wire armour is commonly used
to reduce magnetic losses.
Can this cable be used underground?
Yes. It can be used in underground routes,
cable ducts, trenches and protected direct burial
applications, subject to project specification
and local installation requirements.
What information is required for quotation?
Please confirm voltage rating,
conductor size, conductor material,
armour type and cable length.
Installation method, sheath colour,
standard and destination port
are also required.
Can BURYCABLE supply BS5467
single core armoured cable?
Yes. BURYCABLE can supply BS5467
600/1000V single core XLPE insulated
PVC sheathed armoured power cables.
We can support different conductor sizes,
conductor materials, armour types,
lengths and packing requirements.