300/500V XLPE insulated LSZH sheathed
multicore cable to BS7211 is designed
for fixed wiring and low voltage
building installations.
It is suitable for commercial buildings,
public facilities, hospitals, airports,
schools, data centres and transport systems.
The cable is used where low smoke
zero halogen performance is required
to reduce smoke emission and corrosive gas
release in the event of fire.
The XLPE insulation provides reliable
electrical performance and thermal stability.
The LSZH outer sheath provides low smoke
and halogen free performance for safer
indoor installation environments.
This cable is commonly used for lighting,
power, control and general fixed wiring
circuits in buildings.
As an unarmoured cable, it should be
installed where mechanical protection
is provided by conduit, trunking,
cable tray or other protected wiring systems.
The cable should be selected according to
voltage rating, number of cores,
conductor size, installation method,
fire performance requirement
and project specification.
Basic design to BS 7211:2012
| Flame Retardance (Single vertical wire or cable test) | IEC 60332-1-2; EN 60332-1-2 |
| Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) | IEC 60332-3-24; EN 60332-3-24 |
| Halogen Free | IEC 60754-1; EN 50267-2-1 |
| No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2 |
| Minimum Smoke Emission | IEC 61034-2; EN 61034-2 |
300/500V
Conductor : Annealed copper conductor, solid or stranded according to BS EN 60228 class 1 or class 2.
Insulation : XLPE type GP8 according to BS 7655-1.3. Crosslinked polyolefin material type EI 5 according to EN 50363-5 can be offered as option.
CPC (Circuit Protective Conductor) : Uninsulated copper conductor.
Outer Sheath : Extruded LSZH type LTS 2 according to BS 7655-6.1.
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.
Insulation Colour :
Twin : Brown and blue or, for 2x1.0 and 2x1.5 cables, brown and brown.
Three cores : Brown, black (centre core) and grey.
Position of CPC :
Twin : Centrally placed between cores in same plane.
Three cores : Centrally placed between black and grey cores in same plane.
Sheath Colour : White; other colours can be offered upon request.
Maximum temperature range during operation : 90°C
Maximum short circuit temperature (5 Seconds) : 250°C
Minimum bending radius :
OD<8mm : 4 × Overall Diameter
8mm≤OD≤12mm : 5 × Overall Diameter
OD>12mm : 6 × Overall Diameter
| Conductor | FLP300-RZ1-U/R | |||||||
|---|---|---|---|---|---|---|---|---|
| No. of Cores × Cross-sectional Area | Conductor Class | Nominal Insulation Thickness | Cross-sectional Area of CPC | Class of CPC | Nominal Sheath Thickness | Min. overall Dimensions | Max. overall Dimensions | Approx. Weight |
| No.×mm² | mm | mm² | mm | mm | mm | kg/km | ||
| 2×1.0 | 1 | 0.7 | 1.0 | 1 | 0.9 | 4.1×7.6 | 5.0×9.2 | 68 |
| 2×1.5 | 1 | 0.7 | 1.0 | 1 | 0.9 | 4.4×8.1 | 5.3×9.7 | 85 |
| 2×2.5 | 1 | 0.7 | 1.5 | 1 | 1.0 | 4.9×9.3 | 6.0×11.2 | 120 |
| 3×1.0 | 1 | 0.7 | 1.0 | 1 | 0.9 | 4.1×10.0 | 5.0×12.1 | 91 |
| 3×1.5 | 1 | 0.7 | 1.0 | 1 | 0.9 | 4.4×10.7 | 5.3×12.9 | 115 |
| 3×2.5 | 1 | 0.7 | 1.5 | 1 | 1.0 | 4.9×12.0 | 6.0×14.6 | 170 |
| 2×1.0 | 2 | 0.7 | 1.0 | 1 | 0.9 | 4.2×7.8 | 5.1×9.4 | 73 |
| 2×1.5 | 2 | 0.7 | 1.0 | 1 | 0.9 | 4.5×8.3 | 5.4×10.0 | 90 |
| 2×2.5 | 2 | 0.7 | 1.5 | 1 | 1.0 | 5.0×9.5 | 6.1×11.4 | 125 |
| 2×4 | 2 | 0.7 | 1.5 | 1 | 1.0 | 5.5×10.4 | 6.7×12.6 | 175 |
| 2×6 | 2 | 0.7 | 2.5 | 1 | 1.1 | 6.2×12.0 | 7.5×14.6 | 240 |
| 2×10 | 2 | 0.7 | 4.0 | 2 | 1.2 | 7.3×14.5 | 8.8×17.5 | 390 |
| 2×16 | 2 | 0.7 | 6.0 | 2 | 1.3 | 8.4×17.0 | 10.1×20.5 | 560 |
| 3×4 | 2 | 0.7 | 1.5 | 1 | 1.0 | 5.5×14.0 | 6.7×16.9 | 196 |
| 3×6 | 2 | 0.7 | 2.5 | 1 | 1.1 | 6.2×16.2 | 7.5×19.5 | 291 |
| 3×10 | 2 | 0.7 | 4.0 | 2 | 1.2 | 7.3×19.5 | 8.8×23.6 | 440 |
| 3×16 | 2 | 0.7 | 6.0 | 2 | 1.3 | 8.4×22.8 | 10.1×27.6 | 670 |
Conductor operating temperature : 90°C
Ambient temperature : 30°C
| Conductor Cross-sectional area | Ref. Method A (enclosed in conduit in thermally insulating wall etc.) | Ref. Method B (enclosed in conduit on a wall or in trunking etc.) | Ref. Method C (clipped direct) | Ref. Method E (free air or on a perforated cable tray etc. horizontal or vertical) | ||||
|---|---|---|---|---|---|---|---|---|
| 1 two-core cable*, single-phase a.c. or d.c. | 1 three-or four core cable*, three- phase a.c. | 1 two-core cable*, single- phase a.c. or d.c. | 1 three-or four core cable*, three-phase a.c. | 1 two-core cable*, single-phase a.c. or d.c. | 1 three-or four core cable*, three- phase a.c. | 1 two-core cable*, single- phase a.c. or d.c. | 1 three-or four core cable*, three- phase a.c. | |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| mm² | A | A | A | A | A | A | A | A |
| 1.0 | 14.5 | 13 | 17 | 15 | 19 | 17 | 21 | 18 |
| 1.5 | 18.5 | 16.5 | 22 | 19.5 | 24 | 22 | 26 | 23 |
| 2.5 | 25 | 22 | 30 | 26 | 33 | 30 | 36 | 32 |
| 4 | 33 | 30 | 40 | 35 | 45 | 40 | 49 | 42 |
| 6 | 42 | 38 | 51 | 44 | 58 | 52 | 63 | 54 |
| 10 | 57 | 51 | 69 | 60 | 80 | 71 | 86 | 75 |
| 16 | 76 | 68 | 91 | 80 | 107 | 96 | 115 | 100 |
Note: With or without a protective conductor.
| Conductor cross-sectional area | Two-core cable, d.c. | Two-core cable, single-phase a.c. | Three or four core cable, three-phase a.c. |
|---|---|---|---|
| 1 | 2 | 3 | 4 |
| mm² | mV/A/m | mV/A/m | mV/A/m |
| 1.0 | 46 | 46 | 40 |
| 1.5 | 31 | 31 | 27 |
| 2.5 | 19 | 19 | 16 |
| 4 | 12 | 12 | 10 |
| 6 | 7.9 | 7.9 | 6.8 |
| 10 | 4.7 | 4.7 | 4.0 |
| 16 | 2.9 | 2.9 | 2.5 |
KEY FEATURES
- Designed according to BS7211 requirements
- 300/500V voltage rating
- XLPE insulated conductors
- LSZH / LSOH outer sheath
- Multicore cable construction
- Low smoke zero halogen performance
- Suitable for fixed wiring installation
- Suitable for public buildings and commercial buildings
- Suitable for indoor protected cable routes
- Suitable for lighting, power and control circuits
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Number of cores
- Conductor size
- Cable length
- Sheath colour
- Installation method
- Fire performance requirement
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
BS7211 300/500V XLPE insulated
LSZH sheathed multicore cable is commonly
selected for indoor fixed wiring where
low smoke zero halogen performance
is required.
It is suitable for buildings and public
facilities where smoke emission and
corrosive gas release need to be reduced
in the event of fire.
For installations requiring mechanical
protection, the cable should be installed
in conduit, trunking, cable tray
or other protected routes.
RELATED CABLE TYPES
- BS7211 cable
- 6241B cable
- 6242B cable
- 6243B cable
- 6491B cable
- 6181B cable
- BS6724 LSZH armoured cable
- BS5467 PVC armoured cable
- LSZH building cable
- Fixed wiring cable
FAQ
What is this BS7211 cable used for?
This cable is used for fixed wiring
and low voltage building installations.
It is suitable for commercial buildings,
public facilities, hospitals, airports,
schools, data centres and transport systems.
What is the voltage rating of this cable?
This page is for 300/500V
XLPE insulated LSZH sheathed multicore
cable to BS7211.
Is this cable LSZH?
Yes. This cable uses an LSZH / LSOH
outer sheath to reduce smoke emission
and corrosive gas release in the event of fire.
Is this cable armoured?
No. This is an unarmoured fixed wiring cable.
Where mechanical protection is required,
it should be installed in conduit,
trunking, cable tray or other protected routes.
Is BS7211 the same as BS6724?
No. BS7211 is generally used for
unarmoured LSZH building wiring cables.
BS6724 is normally used for LSZH
armoured power cables.
Can this cable be used outdoors?
It is mainly selected for indoor
and protected fixed wiring installations.
Outdoor use should be confirmed
according to project specification
and installation conditions.
What information is required for quotation?
Please confirm voltage rating,
number of cores, conductor size,
cable length, sheath colour,
installation method and required standard.
Destination port or delivery address
is also required.
Can BURYCABLE supply BS7211 cable?
Yes. BURYCABLE can supply BS7211
XLPE insulated LSZH sheathed cables
according to project voltage, core number,
conductor size, length and packing requirements.