450/750V XLPE Insulated LSZH Sheathed Multicore Cable to BS7211
450/750V XLPE insulated LSZH sheathed multicore cable to BS7211 is designed for fixed wiring in buildings, public facilities, hospitals, airports and indoor installations requiring low smoke zero halogen performance.
450_750V XLPE Insulated, LSZH Sheathed Power Cables to BS 7211 (2-5 Cores).pdf Contact us

APPLICATION

450/750V XLPE insulated LSZH sheathed

multicore cable to BS7211 is designed

for fixed wiring and low voltage

building installations.


It is suitable for commercial buildings,

public facilities, hospitals, airports,

schools, data centres and transport systems.


The cable is used where low smoke

zero halogen performance is required

to reduce smoke emission and corrosive gas

release in the event of fire.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH outer sheath provides low smoke

and halogen free performance for safer

indoor installation environments.


This cable is commonly used for lighting,

power, control and general fixed wiring

circuits in buildings.


As an unarmoured cable, it should be

installed where mechanical protection

is provided by conduit, trunking,

cable tray or other protected wiring systems.


The cable should be selected according to

voltage rating, number of cores,

conductor size, installation method,

fire performance requirement

and project specification.


STANDARDS

Basic design to BS 7211:2012

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

450/750V

CABLE CONSTRUCTION

Conductor : Annealed copper conductor, solid or stranded according to BS EN 60228 class 1 or class 2.

Insulation : XLPE type GP8 according to BS 7655-1.3. Crosslinked polyolefin material type EI 5 according to EN 50363-5 can be offered as option.

Inner Covering Option : The optional inner covering, where used, shall consist of an extruded layer of synthetic polymeric material. It shall surround the laid-up two, three, four or five cores, giving the assembly a practically circular shape.

Outer Sheath : Extruded LSZH type LTS 4 according to BS 7655-6.1.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour :

2-core : Brown and blue.

3-core : Brown, black and grey.

4-core : Blue, brown, black and grey.

5-core : Green/yellow, blue, brown black and grey.

Sheath Colour : White; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius :

OD<8mm : 4 × Overall Diameter

8mm≤OD≤12mm : 5 × Overall Diameter

OD>12mm : 6 × Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP450-RZ1-U/R
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessNominal Inner Covering ThicknessNominal Sheath ThicknessMin. Overall DiameterMax. Overall DiameterApprox. Weight
No.×mm² mmmmmmmmmmkg/km
2×1.010.70.41.27.19.594
2×1.510.70.41.27.610.1121
2×2.510.70.41.28.411.0165
2×410.70.41.29.212.1212
2×610.70.41.210.213.2272
2×1010.70.41.412.116.0446
2×1.020.70.41.27.39.7110
2×1.520.70.41.27.810.3132
2×2.520.70.41.28.511.3178
2×420.70.41.29.512.4232
2×620.70.41.210.613.7302
2×1020.70.61.412.716.7490
2×1620.70.61.414.418.8674
2×2520.90.81.417.723.21040
2×3520.90.81.620.026.01130
3×1.010.70.41.27.510.0110
3×1.510.70.41.28.010.6143
3×2.510.70.41.28.811.6198
3×410.70.41.29.812.7260
3×610.70.41.211.214.4387
3×1010.70.61.412.816.9557
3×1.020.70.41.27.710.2128
3×1.520.70.41.28.210.9156
3×2.520.70.41.29.011.9213
3×420.70.41.210.113.1282
3×620.70.41.411.615.0387
3×1020.70.61.413.517.7607
3×1620.70.61.415.319.9850
3×2520.90.81.418.924.61315
3×3520.90.81.621.327.61562
4×1.010.70.41.28.110.7130
4×1.510.70.41.28.711.4170
4×2.510.70.41.29.612.6240
4×410.70.41.210.713.8330
4×610.70.41.412.216.1445
4×1010.70.61.414.118.4687
4×1.020.70.41.28.311.0150
4×1.520.70.41.28.911.7185
4×2.520.70.41.29.912.8256
4×420.70.41.211.014.2344
4×620.70.61.412.716.7490
4×1020.70.61.414.819.2747
4×1620.70.61.416.921.81055
4×2520.90.81.621.227.51670
4×3520.91.01.623.530.72044
5×1.010.70.41.28.811.5157
5×1.510.70.41.29.412.3208
5×2.510.70.41.210.513.6295
5×410.70.41.412.015.9422
5×610.70.61.413.317.5551
5×1010.70.61.415.420.0858
5×1.020.70.41.29.011.9183
5×1.520.70.41.29.712.6227
5×2.520.70.41.210.713.9317
5×420.70.61.412.416.4460
5×620.70.61.413.818.1610
5×1020.70.61.416.220.9937
5×1620.70.81.418.524.21328
5×2520.91.01.623.330.51860
5×3520.91.01.625.933.62500

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E2A

Conductor cross-sectional areaRef. Method A (enclosed in conduit in thermally insulating wall etc.)Ref. Method B (enclosed in conduit on a wall or in trunking etc.)Ref. Method C (clipped direct)Ref. Method E (in free air or on a perforated cable tray etc. horizontal or vertical)
1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.
123456789
mm²AAAAAAAA
1.014.513171519172118
1.518.516.52219.524222623
2.52522302633303632
43330403545404942
64238514458526354
105751696080718675
167668918010796115100
259989119105138119149127
35121109146128171147185158

Note: With or without a protective conductor.

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E2B

Conductor cross-sectional areaTwo-core cable, d.c.Two-core cable, single-phase a.c.Three- or four-core cable, three-phase a.c.
1234
mm²mV/A/mmV/A/mmV/A/m
1.0464640
1.5313127
2.5191916
4121210
67.97.96.8
104.74.74.0
162.92.92.5


rxzrxz
251.851.850.1601.901.600.1401.65
351.351.350.1551.351.150.1351.15

Note :

r = conductor resistance at operating temperature

x = reactance

z = impedance

KEY FEATURES


- Designed according to BS7211 requirements

- 450/750V voltage rating

- XLPE insulated conductors

- LSZH / LSOH outer sheath

- Multicore cable construction

- Low smoke zero halogen performance

- Suitable for fixed wiring installation

- Suitable for public buildings and commercial buildings

- Suitable for indoor protected cable routes

- Suitable for lighting, power and control circuits



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Number of cores

- Conductor size

- Cable length

- Sheath colour

- Installation method

- Fire performance requirement

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


BS7211 450/750V XLPE insulated

LSZH sheathed multicore cable is commonly

selected for indoor fixed wiring where

low smoke zero halogen performance

is required.


It is suitable for buildings and public

facilities where smoke emission and

corrosive gas release need to be reduced

in the event of fire.


For installations requiring mechanical

protection, the cable should be installed

in conduit, trunking, cable tray

or other protected routes.



RELATED CABLE TYPES


- BS7211 cable

- 6241B cable

- 6242B cable

- 6243B cable

- 6491B cable

- 6181B cable

- 300/500V BS7211 cable

- BS6724 LSZH armoured cable

- LSZH building cable

- Fixed wiring cable



FAQ


What is this BS7211 cable used for?


This cable is used for fixed wiring

and low voltage building installations.


It is suitable for commercial buildings,

public facilities, hospitals, airports,

schools, data centres and transport systems.



What is the voltage rating of this cable?


This page is for 450/750V

XLPE insulated LSZH sheathed multicore

cable to BS7211.



Is this cable LSZH?


Yes. This cable uses an LSZH / LSOH

outer sheath to reduce smoke emission

and corrosive gas release in the event of fire.



Is this cable armoured?


No. This is an unarmoured fixed wiring cable.


Where mechanical protection is required,

it should be installed in conduit,

trunking, cable tray or other protected routes.



Is BS7211 the same as BS6724?


No. BS7211 is generally used for

unarmoured LSZH building wiring cables.


BS6724 is normally used for LSZH

armoured power cables.



Can this cable be used outdoors?


It is mainly selected for indoor

and protected fixed wiring installations.


Outdoor use should be confirmed

according to project specification

and installation conditions.



What information is required for quotation?


Please confirm voltage rating,

number of cores, conductor size,

cable length, sheath colour,

installation method and required standard.


Destination port or delivery address

is also required.



Can BURYCABLE supply BS7211 cable?


Yes. BURYCABLE can supply BS7211

XLPE insulated LSZH sheathed cables

according to project voltage, core number,

conductor size, length and packing requirements.