600/1000V Single Core XLPE Insulated LSZH Sheathed Power Cable to BS 8573
600/1000V single core XLPE insulatedLSZH sheathed power cable to BS 8573.Suitable for fixed power distributionin public buildings, tunnels,transport systems, hospitals,hotels and industrial facilities.
600_1000V XLPE Insulated, LSZH Sheathed Power Cables to BS 8573 (Single Core).pdf Contact us

APPLICATION

600/1000V single core XLPE insulated

LSZH sheathed power cable is designed

for fixed low voltage power distribution.


It is suitable for public buildings,

commercial buildings, industrial facilities,

tunnels, transport systems, hotels

and hospitals.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH sheath helps reduce smoke emission

and corrosive gas release in the event of fire.


This cable is commonly selected for projects

where flame retardant and halogen-free

performance is required.


As a single core unarmoured cable,

it does not provide metallic armour protection.


It is suitable for cable trays,

cable ducts, risers, panels

and protected fixed installation routes.


Where additional mechanical protection

is required, the cable should be installed

with suitable protection.


The cable should be selected according to

voltage rating, conductor size,

sheath colour, installation method

and project specification.


STANDARDS

Basic design to BS 8573:2012

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor : Annealed copper conductor, stranded according to BS EN 60228 class 2.

Insulation : XLPE type GP8 according to BS 7655-1.3. HEPR type GP6 according to BS 7655-1.2 or crosslinked polyolefin material type EI 5 according to BS EN 50363-5 can be offered as option.

Inner Covering Option : The optional inner covering, where used, shall consist of an extruded layer of synthetic polymeric material. It shall surround the single core and the laid-up two, three, four or five cores, giving the assembly a practically circular shape.

Outer Sheath : Extruded layer of polymeric material LTS 4 according to BS 7655-6.1. Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour : Brown or blue.

Sheath Colour : Black; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius :

circular copper conductors OD≤25mm : 4 × Overall Diameter

circular copper conductors OD﹥25mm : 6 × Overall Diameter

shaped copper conductors : 8 × Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP600-RZ1-R
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessNominal Inner Covering ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.×mm² mmmmmmmmkg/km
1×1.520.70.41.45.854
1×2.520.70.41.46.267
1×420.70.41.46.887
1×620.70.41.47.3113
1×1020.70.41.48.3163
1×1620.70.41.49.3232
1×2520.90.41.411.0346
1×3520.90.41.412.2456
1×5021.00.61.413.7599
1×7021.10.61.415.7835
1×9521.10.61.517.81131
1×12021.20.81.519.61407
1×15021.40.81.621.81727
1×18521.60.81.624.02144
1×24021.71.01.727.12786
1×30021.81.01.829.93466
1×40022.01.21.933.54405
1×50022.21.22.037.25520
1×63022.41.42.242.07097
1×80022.61.62.346.99010
1×100022.81.62.452.011286

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E1A

Conductor cross-sectional areaRef. Method A (enclosed in conduit in thermally insulating wall etc.)Ref. Method B (enclosed in conduit on a wall or in trunking etc.)Ref. Method C (clipped direct)Ref. Method F (in free air or on a perforated cable tray, horizontal or vertical etc.) TouchingRef. Method G (in free air) spaced by one cable diameter
2 cables, single-phase a.c. or d.c.3 or 4 cables, three-phase a.c.2 cables, single-phase a.c. or d.c3 or 4 cables, three-phase a.c.2 cables, single-phase a.c. or d.c. flat and touching3 or 4 cables, three-phase a.c. flat and touching or trefoil2 cables, single-phase a.c. or d.c. flat3 cables, three-phase a.c. flat3 cables, three-phase a.c. trefoil2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat
HorizontalVertical
123456789101112
mm²AAAAAAAAAAA
1.5191723202523-----
2.5262331283431-----
4353142374641-----
6454054485954-----
10615475668174-----
1681731008810999-----
2510695133117143130161141135182161
35131117164144176161200176169226201
50158141198175228209242216207275246
70200179253222293268310279268353318
95241216306269355326377342328430389
120278249354312413379437400383500454
150318285393342476436504464444577527
185362324449384545500575533510661605
240424380528450644590679634607781719
300486435603514743681783736703902833
400--68358486879394086882310851008
500--783666990904108399894612531169
630--9007641130103312541151108814541362
800----1288117913581275121415811485
1000----1443132315201436134917751671

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E1B

Conductor cross-sectional area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, three-phase a.c.
Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)
cables touchingcables spaced*Cables touching, TrefoilCables touching, FlatCables spaced*, Flat
123456789
mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m
1.53131313127272727
2.51919191916161616
41212121210101010
67.97.97.97.96.86.86.86.8
104.74.74.74.74.04.04.04.0
162.92.92.92.92.52.52.52.5


rxzrxzrxzrxzrxzrxzrxz
251.851.850.311.901.850.1901.851.850.281.851.600.271.651.600.1651.601.600.1901.601.600.271.65
351.351.350.291.351.350.1801.351.350.271.351.150.251.151.150.1551.151.150.1801.151.150.261.20
500.991.000.291.050.990.1801.000.990.271.000.870.250.900.860.1550.870.860.1800.870.860.260.89
700.680.700.280.750.680.1750.710.680.260.730.600.240.650.590.1500.610.590.1750.620.590.250.65
950.490.510.270.580.490.1700.520.490.260.560.440.230.500.430.1450.450.430.1700.460.430.250.49
1200.390.410.260.480.390.1650.430.390.250.470.350.230.420.340.1400.370.340.1650.380.340.240.42
1500.320.330.260.430.320.1650.360.320.250.410.290.230.370.280.1400.310.280.1650.320.280.240.37
1850.250.270.260.370.260.1650.300.250.250.360.230.230.320.220.1400.260.220.1650.280.220.240.33
2400.1900.210.260.330.200.1600.250.1950.250.310.1850.220.290.1700.1400.220.1700.1650.240.1700.240.29
3000.1550.1750.250.310.1600.1600.220.1550.250.290.1500.220.270.1400.1400.1950.1350.1600.210.1350.240.27
4000.1200.1400.250.290.1300.1550.200.1250.240.270.1250.220.250.1100.1350.1750.1100.1600.1950.1100.240.26
5000.0930.1200.250.280.1050.1550.1850.0980.240.260.1000.220.240.0900.1350.1600.0880.1600.1800.0850.240.25
6300.0720.1000.250.270.0860.1550.1750.0780.240.250.0880.210.230.0740.1350.1500.0710.1600.1700.0680.230.24
8000.056-0.0720.1500.1700.0640.240.25-0.0620.1300.1450.0590.1550.1650.0550.230.24
10000.045-0.0630.1500.1650.0540.240.24-0.0550.1300.1450.0500.1550.1650.0470.230.24

Note : *Spacings larger than one cable diameter will result in a large voltage drop.

r = conductor resistance at operating temperature

x = reactance

z = impedance

KEY FEATURES


- Designed according to BS 8573 requirements

- 600/1000V voltage rating

- Single core cable construction

- XLPE insulated conductor

- LSZH sheathed construction

- Low smoke performance

- Halogen-free sheath material

- Unarmoured cable design

- Suitable for fixed installation

- Suitable for public buildings and infrastructure projects



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Conductor size

- Conductor material

- Cable length

- Sheath colour

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


600/1000V single core XLPE LSZH cable

is commonly selected for building

and infrastructure power distribution.


It is suitable where low smoke,

halogen-free and flame retardant

performance is required.



RELATED CABLE TYPES


- BS 8573 cable

- BS 6724 cable

- BS 7211 cable

- IEC 60502-1 low voltage cable

- XLPE insulated power cable

- LSZH power cable

- Halogen free cable

- Low smoke cable

- Single core power cable

- Unarmoured power cable



FAQ


What is this cable used for?


It is used for fixed low voltage

power distribution.


It is suitable for public buildings,

commercial buildings, tunnels,

transport systems and industrial facilities.



What standard does this cable follow?


This cable is designed according to

BS 8573 requirements.



Is this cable LSZH?


Yes. This cable has an LSZH sheath.


The sheath helps reduce smoke emission

and corrosive gas release in the event of fire.



Is this cable single core?


Yes. This page is for single core

XLPE insulated LSZH sheathed cable.



Is this cable armoured?


No. This page is for unarmoured cable.


It does not have metallic armour protection.



Is this a fire resistant cable?


This cable has flame retardant

and LSZH performance.


It should not be described as a

BS 6387 circuit integrity fire resistant cable

unless mica tape or circuit integrity

performance is confirmed.



Can this cable be used underground?


It can be used in protected cable ducts

or protected underground routes.


For direct burial or demanding routes,

armoured cable may be required.



What information is required for quotation?


Please confirm voltage rating,

conductor size and cable length.


Installation method, sheath colour,

standard and destination port

are also required.



Can BURYCABLE supply BS 8573

single core XLPE LSZH cable?


Yes. BURYCABLE can supply BS 8573

600/1000V single core XLPE insulated

LSZH sheathed power cables.


We can support different conductor sizes,

lengths and packing requirements.