CAN-Bus Cable, 120 Ohm, Screened Pair or Star Quad, PVC or PUR
120 ohm CAN-Bus cables with stranded bare copper conductors, cellular PE insulation and a tinned copper braid screen. Pair and star-quad constructions are listed in 0.22, 0.34 and 0.50 mm2 sizes, with PVC or PUR sheath options.
CAN-Bus.pdf Contact us

APPLICATION AND DESCRIPTION

Choose this CAN-Bus range for industrial communication wiring that calls for a 120 ohm screened cable. Pair and star-quad constructions use stranded bare copper conductors with cellular PE insulation. PVC is the listed sheath option for static use, while PUR is the option for flexing applications.

CONSTRUCTION

Type/Area of ApplicationFixed Installation, IndoorFixed Installation, Indoor
Cable Construction1x2x0.22 mm2 (stranded)4x1x0.22 mm2 (stranded)

1x2x0.34 mm2 (stranded)4x1x0.34 mm2 (stranded)

1x2x0.50 mm2 (stranded)4x1x0.50 mm2 (stranded)
Inner ConductorCopper, bare (AWG 24/7)Copper, bare (AWG 24/7)

Copper, bare (AWG 22/7)Copper, bare (AWG 22/7)

Copper, bare (AWG 20/7)Copper, bare (AWG 20/7)
Conductor InsulationCellularPECellular PE
Conductor Colorswhite, brownwhite, brown, green-yellow
Stranding ElementDouble conductorStar quad
WrappingPolyester foil over stranded bundlePolyester foil over stranded bundle
Shielding--
Total ShieldingCopper braid, tinnedCopper braid, tinned
Outer Jacket MaterialPVC(static) / PUR(flexing)PVC(static) / PUR(flexing)
Outer Diameter5.4 mm ± 0.2 mm6.9 mm ± 0.2 mm

6.5 mm ± 0.2 mm8.0 mm ± 0.2 mm

7.0 mm ± 0.2 mm8.5 mm ± 0.2 mm
Outer Jacket ColorVioletViolet

ELECTRICAL DATA

Characteristic Impedance@1MHz120 Ω ± 10 Ω120 Ω ± 10 Ω
Conductor Resistance186.0 Ohm/km max.186.0 Ohm/km max.
Insulation Resistance1.00 GOhm x km min.1.00 GOhm x km min.
Mutual Capacitance@800Hz40.0 nF/km nom.40.0 nF/km nom.
Working Voltage250V250V
Test Voltage1.5 kV1.5 kV

1 MHz1.3 dB/100m
Attenuation5 MHz3.1 dB/100m

10 MHz4.3 dB/100m

20 MHz6.4 dB/100m

TECHNICAL DATA

Weightapproximately 35.0 kg/kmapproximately 60.0 kg/km

approximately 54.0 kg/kmapproximately 77.0 kg/km

approximately 69.0 kg/kmapproximately 100.0 kg/km
Min. Bending Radius (Laying)15 x OD mm15 x OD mm
Operating Temp.Range, min.- 40 °C- 40 °C
Operating Temp.Range, max.+70 °C+70 °C


KEY FEATURES

  • Conductor size options of 0.22, 0.34 and 0.50 mm².

  • Tinned copper braid screening and a violet outer sheath.

  • Pair and star-quad variants with separate diameters and weights.

SELECTION NOTES

Select the core arrangement and conductor size together; each combination has its own cable diameter. The nominal diameters span 5.4 to 8.5 mm across the range. Specify the movement duty when choosing PUR, and follow the network equipment requirements for cable routing, connections and termination.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Which conductor sizes are available?

The construction table lists 0.22, 0.34 and 0.50 mm² stranded copper conductors.

What is the difference between the core arrangements?

The pair construction has two insulated conductors. The star-quad construction has four conductors arranged as a quad.

How is the cable screened?

An overall tinned copper braid surrounds the core assembly.

Which sheath is intended for static wiring?

PVC is listed for static use; PUR is listed for flexing use.

Is one cable diameter used for the whole range?

No. Diameter depends on conductor size and core arrangement; the individual dimensions are shown in the construction table.