Profinet Type A Cable, 100 Ohm, Solid Copper, PVC or PUR Sheath
Profinet Type A cable for fixed installation, with solid AWG 22 copper conductors, a star-quad assembly, foil and braid screens, and PVC or PUR outer sheath options. Both versions have a nominal diameter of 6.5 mm.
ProfiNet Type A.pdf Contact us

APPLICATION AND DESCRIPTION

This Profinet Type A range provides copper network cabling for fixed industrial Ethernet routes. Four solid copper cores form a star quad, enclosed by foil and tinned copper braid screens. The indoor construction has a PVC outer sheath; the heavy-duty construction uses PUR over the PVC inner jacket.

CONSTRUCTION

Type/Area of ApplicationFixed Installation, IndoorHeavy Duty
Cable Construction2x2x0.64 mm2x2x0.64 mm
Inner Conductor DiameterCopper, bare (AWG 22/1)Copper, bare (AWG 22/1)
Conductor InsulationPEPE
Conductor Colorswhite, yellow, blue, orangewhite, yellow, blue, orange
Stranding ElementStar quadStar quad
WrappingPolyester foil over stranded bundlePolyester foil over stranded bundle
ShieldingPolyester foil, aluminum-linedPolyester foil, aluminum-lined
Total ShieldingCu braid, tinnedCu braid, tinned
Inner Jacket MaterialPVCPVC
Outer Jacket MaterialPVCPUR
Outer Diameter6.5 mm ± 0.2 mm6.5 mm ± 0.2 mm
Outer Jacket ColorGreenGreen

ELECTRICAL DATA

Characteristic Impedance@1-100 MHz100 Ohm ± 15 Ohm
Conductor Resistance62.0 Ohm/km max.
Insulation Resistance0.50 GOhm x km min.
Mutual Capacitance50.0 nF/km nom.
Working Voltage300V
Test Voltage1.5 KV

10 MHz5.2 dB/100m
Attenuation16 MHz6.9 dB/100m

62.5 MHz16.0 dB/100m

100 MHz19.5 dB/100m

TECHNICAL DATA

Weightapproximately 67.0 kg/kmapproximately 64.0 kg/km
Min. Bending Radius (Laying)5 x OD mm10 x OD mm
Operating Temp. Range, min.-40 °C-40 °C
Operating Temp.Range, max.+70 °C+70 °C


KEY FEATURES

  • Solid AWG 22/1 bare copper conductors with PE insulation.

  • White, yellow, blue and orange cores in a screened star-quad assembly.

  • 100 ± 15 ohms impedance at 1–100 MHz; nominal diameter 6.5 mm.

SELECTION NOTES

Select the PVC or PUR construction according to the installation environment. Although both have the same nominal diameter, their laying bend limits differ: 5 times the overall diameter for the indoor PVC version and 10 times for the heavy-duty PUR version. Use the Type B or B+C ranges when the route includes movement.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Where is Type A cable used?

On fixed Profinet routes where the cable remains stationary after installation.

How do the two sheath versions differ?

The indoor version has PVC inner and outer jackets. The heavy-duty version combines a PVC inner jacket with a PUR outer sheath.

Are these solid or stranded conductors?

Both constructions use solid bare copper conductors designated AWG 22/1.

What is the cable diameter?

Both versions are 6.5 ± 0.2 mm in overall diameter.

Do both versions have the same laying radius?

No. The indoor PVC version specifies 5 times the overall diameter, while the heavy-duty PUR version specifies 10 times.