Safety Bus Cable, 120 Ohm, 3-Core Screened Copper, 0.75 mm2
Safety Bus cable for fixed indoor installation, with three stranded 0.75 mm2 copper cores, foamed PP insulation and a tinned copper braid screen. Nominal impedance is 120 ohms and the outer sheath is yellow.
Safety Bus.pdf Contact us

APPLICATION AND DESCRIPTION

This three-core Safety Bus cable is intended for fixed indoor wiring in compatible CAN-based fieldbus systems. Stranded bare copper conductors have foamed PP insulation with a hard skin, with an overall tinned copper braid enclosing the assembly. A yellow outer sheath identifies the cable along the installed route.

CONSTRUCTION

Area of ApplicationFixed Installation, Indoor
Cable Construction3x0.75 mm2 (stranded)
Inner Conductor DiameterCopper, bare (AWG 18/24)
Conductor InsulationFoamed PP with a hard skin
Conductor Colorswhite, brown, green
Stranding ElementTriple conductor
WrappingPolyester foil over stranded bundle
Total ShieldingCopper braid, tinned
Outer Jacket MaterialFRNC/PUR/PVC/LSHF
Outer Diameter7.5 mm ± 0.3 mm
Outer Jacket ColorYellow

ELECTRICAL DATA

Characteristic Impedance@1MHz120 Ω ± 10 Ω
Conductor Resistance52.0 Ohm/km max.
Insulation Resistance0.20 GOhm x km min.
Mutual Capacitance@800Hz45.0 nF/km nom.
Working VoltageMax: 250 V
Test Voltage3.0 KV
Data Rate500 Kbit/s100m

250 Kbit/s250m

125 Kbit/s500m

50 Kbit/s1000m
Attenuation1MHz<1.6dB/100m

5MHz<3.4dB/100m

10MHz<5.6dB/100m

16MHz<7.5dB/100m

TECHNICAL DATA

Weightapproximately 68.0 kg/km
Min. Bending Radius (Laying)10 x OD mm
Operating Temp.Range, min.- 30 °C
Operating Temp.Range, max.+80 °C


KEY FEATURES

  • Three 0.75 mm² stranded copper cores, coloured white, brown and green.

  • 120 ± 10 ohms characteristic impedance at 1 MHz.

  • FRNC, PUR, PVC and LSHF sheath options; nominal outer diameter 7.5 mm.

SELECTION NOTES

Match the cable to the equipment interface and select the sheath material for the installation. Specify the network speed and route length together, then check the complete network against the system manufacturer’s wiring requirements. The cable construction is one part of the installation; functional safety is established at system level.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

How many conductors are in this cable?

Three stranded copper conductors, each with a nominal cross-sectional area of 0.75 mm².

What are the core and sheath colours?

The cores are white, brown and green. The outer sheath is yellow.

Which installation type is listed?

Fixed indoor installation. The listed laying radius is 10 times the overall diameter.

What overall diameter is specified?

The cable diameter is 7.5 ± 0.3 mm.

How is the conductor assembly screened?

An overall tinned copper braid surrounds the polyester-wrapped core assembly.