RE-2X(St)H 500V XLPE LSZH Multicore Instrumentation Cable
RE-2X(St)H 500V XLPE insulated multicore instrumentation cable with an overall foil screen, LSZH sheath. For fixed industrial instrument and control connections.
RE-2X(St)H Multi-Core.pdf Contact us

APPLICATION

BURY CABLE RE-2X(St)H multicore cable connects instruments and control equipment in industrial process facilities. Copper conductors with XLPE insulation, an overall aluminium/polyester screen and an unarmoured LSZH outer sheath support fixed signal wiring. Use protected indoor routes, including suitable wet or damp locations. Numbered insulated cores simplify circuit identification during installation. The LSZH sheath suits projects specifying low smoke and halogen free materials.

Standards

Basic design to EN 50288-7

Fire Performance

Flame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation(Vertically-mounted bundled wires & cable test)***EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gasesNES 02-713; NF C 20-454
Sunlight ResistanceUL 1581 section 1200
Oil Resistance**ICEA S-73-532

Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.

Voltage Rating

500V

Cable Construction

Conductor : Annealed copper solid or plain copper stranded to IEC 60228 Class 2.

Insulation : Extruded cross-linked XLPE compound, EN 50290. 2-29.

Overall Screen : Aluminium/polyester tape with tinned copper drain wire, 0.5mm²

Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound typeSW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

Colour Code

Insulation : Black numbered

Outer Sheath : Black, blue for intrinsically safe systems

Physical and Thermal Properties

Temperature Range During Operation (Fixed State) : -30°C – +90°C

Temperature Range During Installation (Mobile State) : -5°C – +50°C

Minimum Bending Radius : 7.5 × Overall Diameter

Electrical Roperties

Conductor Area Sizemm²0.50.751.01.31.52.5
Insulation thickness (nominal)mm0.550.550.550.60.60.7
Conductor resistance (20°C)Ω/km36.725.018.514.212.37.4
Insulation resistance (20°C)MΩ.km(Min.)5000
Mutual Capacitance (1 kHz)pF/m(Max.)115
Capacitance unbalance(1 kHz)pF/500 m (Max.)500
L / R (ratio) (max.)μH/Ω252525404060
Operating voltageV500
Test Voltage UrmsCore to CoreV2000
Core to ScreenV2000

Construction Parameterst

Cable CodeRE-2X(St)H
No. of Core x1xCross SectionNominal Insulation ThicknessNominal Sheath ThicknessNominalOverall DiameterApprox. Weight
No.×1×mm²mmmmmmkg/km
0.5mm², Multicore
RE-2X(St)H 2C0.52x1x0.50.550.96.247
RE-2X(St)H 3C0.53x1x0.50.550.96.550
RE-2X(St)H 4C0.54x1x0.50.550.97.060
RE-2X(St)H 5C0.55x1x0.50.550.97.671
RE-2X(St)H 8C0.58x1x0.50.551.09.195
RE-2X(St)H 10C0.510x1x0.50.551.010.4127
RE-2X(St)H 12C0.512x1x0.50.551.010.7151
RE-2X(St)H 14C0.514x1x0.50.551.011.3162
RE-2X(St)H 16C0.516x1x0.50.551.111.8180
RE-2X(St)H 20C0.520x1x0.50.551.113.3222
RE-2X(St)H 24C0.524x1x0.50.551.114.7274
RE-2X(St)H 27C0.527x1x0.50.551.215.0282
RE-2X(St)H 30C0.530x1x0.50.551.215.7318
RE-2X(St)H 37C0.537x1x0.50.551.216.9372
RE-2X(St)H 40C0.540x1x0.50.551.217.6372
0.75mm², Multicore
RE-2X(St)H 2C0.752x1x0.750.550.96.551
RE-2X(St)H 3C0.753x1x0.750.550.96.962
RE-2X(St)H 4C0.754x1x0.750.550.97.474
RE-2X(St)H 5C0.755x1x0.750.550.98.196
RE-2X(St)H 8C0.758x1x0.750.551.09.7126
RE-2X(St)H 10C0.7510x1x0.750.551.011.1156
RE-2X(St)H 12C0.7512x1x0.750.551.011.5183
RE-2X(St)H 14C0.7514x1x0.750.551.112.2200
RE-2X(St)H 16C0.7516x1x0.750.551.112.9224
RE-2X(St)H 20C0.7520x1x0.750.551.114.3284
RE-2X(St)H 24C0.7524x1x0.750.551.216.0324
RE-2X(St)H 27C0.7527x1x0.750.551.216.3363
RE-2X(St)H 30C0.7530x1x0.750.551.216.9396
RE-2X(St)H 37C0.7537x1x0.750.551.218.2472
RE-2X(St)H 40C0.7540x1x0.750.551.319.1514
1.0mm², Multicore
RE-2X(St)H 2C1.02x1x1.00.550.96.961
RE-2X(St)H 3C1.03x1x1.00.550.97.370
RE-2X(St)H 4C1.04x1x1.00.550.97.985
RE-2X(St)H 5C1.05x1x1.00.550.98.6109
RE-2X(St)H 8C1.08x1x1.00.551.010.3157
RE-2X(St)H 10C1.010x1x1.00.551.011.9193
RE-2X(St)H 12C1.012x1x1.00.551.012.2214
RE-2X(St)H 14C1.014x1x1.00.551.113.0243
RE-2X(St)H 16C1.016x1x1.00.551.113.7280
RE-2X(St)H 20C1.020x1x1.00.551.115.2336
RE-2X(St)H 24C1.024x1x1.00.551.217.0414
RE-2X(St)H 27C1.027x1x1.00.551.217.4443
RE-2X(St)H 30C1.030x1x1.00.551.218.0484
RE-2X(St)H 37C1.037x1x1.00.551.219.6590
RE-2X(St)H 40C1.040x1x1.00.551.320.4631
1.3mm², Multicore
RE-2X(St)H 2C1.32x1x1.30.60.97.469
RE-2X(St)H 3C1.33x1x1.30.60.97.983
RE-2X(St)H 4C1.34x1x1.30.60.98.5105
RE-2X(St)H 5C1.35x1x1.30.61.09.5135
RE-2X(St)H 8C1.38x1x1.30.61.011.2186
RE-2X(St)H 10C1.310x1x1.30.61.113.2228
RE-2X(St)H 12C1.312x1x1.30.61.113.6269
RE-2X(St)H 14C1.314x1x1.30.61.114.3305
RE-2X(St)H 16C1.316x1x1.30.61.115.0351
RE-2X(St)H 20C1.320x1x1.30.61.216.9423
RE-2X(St)H 24C1.324x1x1.30.61.218.7507
RE-2X(St)H 27C1.327x1x1.30.61.319.3558
RE-2X(St)H 30C1.330x1x1.30.61.320.0611
RE-2X(St)H 37C1.337x1x1.30.61.321.6743
RE-2X(St)H 40C1.340x1x1.30.61.422.7796
1.5mm², Multicore
RE-2X(St)H 2C1.52x1x1.50.60.97.778
RE-2X(St)H 3C1.53x1x1.50.60.98.198
RE-2X(St)H 4C1.54x1x1.50.60.98.8120
RE-2X(St)H 5C1.55x1x1.50.61.09.8153
RE-2X(St)H 8C1.58x1x1.50.61.011.6218
RE-2X(St)H 10C1.510x1x1.50.61.113.7268
RE-2X(St)H 12C1.512x1x1.50.61.114.1315
RE-2X(St)H 14C1.514x1x1.50.61.114.8341
RE-2X(St)H 16C1.516x1x1.50.61.115.6392
RE-2X(St)H 20C1.520x1x1.50.61.217.6484
RE-2X(St)H 24C1.524x1x1.50.61.319.6579
RE-2X(St)H 27C1.527x1x1.50.61.320.1626
RE-2X(St)H 30C1.530x1x1.50.61.320.8685
RE-2X(St)H 37C1.537x1x1.50.61.422.6834
RE-2X(St)H 40C1.540x1x1.50.61.423.6898
2.5mm², Multicore
RE-2X(St)H 2C2.52x1x2.50.70.98.9111
RE-2X(St)H 3C2.53x1x2.50.71.09.7132
RE-2X(St)H 4C2.54x1x2.50.71.010.5169
RE-2X(St)H 5C2.55x1x2.50.71.011.9209
RE-2X(St)H 8C2.58x1x2.50.71.113.9321
RE-2X(St)H 10C2.510x1x2.50.71.216.3386
RE-2X(St)H 12C2.512x1x2.50.71.216.9447
RE-2X(St)H 14C2.514x1x2.50.71.217.7509
RE-2X(St)H 16C2.516x1x2.50.71.318.9585
RE-2X(St)H 20C2.520x1x2.50.71.321.1712
RE-2X(St)H 24C2.524x1x2.50.71.423.6855
RE-2X(St)H 27C2.527x1x2.50.71.424.1956
RE-2X(St)H 30C2.530x1x2.50.71.525.21049
RE-2X(St)H 37C2.537x1x2.50.71.527.21277
RE-2X(St)H 40C2.540x1x2.50.71.628.51370




KEY FEATURES

  • XLPE insulation with numbered cores and an overall foil screen.

  • Unarmoured construction with an LTS3 LSZH outer sheath; thermosetting sheath options are listed in the technical description.

  • Electrical and construction tables cover 0.5-2.5 mm² conductor sections, with original dimensions and weights retained.

SELECTION NOTES

  • Specify core count, conductor size and construction, circuit voltage, cable length and termination arrangement.

  • Coordinate screen bonding and mechanical route protection with the installation design. Use a minimum bending radius of 7.5 times overall diameter.

  • Choose black or blue sheath identification for the specified system. Blue identification is coordinated with the complete intrinsically safe circuit design; environmental sheath options form part of the order specification.

RELATED CABLE TYPES

FAQ

What is RE-2X(St)H cable used for?

It connects instruments and control equipment on fixed industrial signal routes using a multicore copper cable with XLPE insulation and an LSZH sheath.

How are the conductors arranged?

Individual insulated cores are laid up as a multicore assembly, with numbered core identification.

Which screening construction is used?

An aluminium/polyester foil screen surrounds the complete core assembly, with a tinned copper drain wire for screen connection.

What does the LSZH sheath provide?

The low smoke zero halogen sheath is selected where reduced smoke and corrosive combustion gases are part of the installation specification.

How is the cable selected for installation?

Match the core count, conductor cross-section, circuit voltage and route conditions. Include cable length, screen termination, sheath colour and packing in the order.