whatsapp
backtop
600/1000V Single Core XLPE Insulated LSZH Sheathed Armoured Cable to IEC 60502-1
600/1000V single core XLPE insulated LSZH sheathedarmoured cable to IEC 60502-1.Suitable for low voltage power distribution,public buildings, transport systems,underground routes and infrastructure projects.
600_1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables to IEC 60502-1 (Single Core).pdf Contact us

APPLICATION

600/1000V single core XLPE insulated

LSZH sheathed armoured cable is designed

for fixed low voltage power distribution.


It is suitable for industrial plants,

commercial buildings, public buildings,

transport systems and infrastructure projects.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH sheath helps reduce smoke emission

and corrosive gas release in the event of fire.


The armoured construction provides improved

mechanical protection.


It is suitable for cable ducts,

underground cable routes, cable trenches

and protected outdoor installation.


For single core armoured cable,

the armour type should be selected

according to project requirements.


The cable should be selected according to

voltage rating, conductor size,

conductor material, armour type,

fire performance requirement

and project specification.


STANDARDS

Basic design to IEC 60502-1

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor : The conductors shall be class 2 plain or metal-coated annealed copper in accordance with IEC 60228. Class 1 and class 5 conductor can be offered as option.

Insulation : Thermosetting XLPE compound as per IEC 60502-1.

Inner Covering Option : Thermoplastic halogen free compound ST8 as per IEC 60502-1.

Armouring : Aluminium wire.

Outer Sheath : Thermoplastic halogen free compound ST8 as per IEC 60502-1.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour : Brown or blue; other colours can be offered upon request.

Sheath Colour : Black; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius : 6 × Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP600-RZ1MAZ1-R
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessNominal Inner Covering ThicknessNominal AL Wire DiameterNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.×mm² mmmmmmmmmmkg/km
1×420.71.00.81.811.2200
1×620.71.00.81.811.7233
1×1020.71.00.81.812.7294
1×1620.71.00.81.813.7377
1×2520.91.00.81.815.4513
1×3520.91.01.251.817.5688
1×5021.01.01.251.819.0856
1×7021.11.01.251.821.01124
1×9521.11.01.61.824.01521
1×12021.21.01.61.825.81831
1×15021.41.01.61.827.82176
1×18521.61.01.61.830.42668
1×24021.71.01.61.933.53367
1×30021.81.02.02.037.54241
1×40022.01.22.02.241.35283
1×50022.21.22.02.345.46535

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E3A

Conductor cross-sectional areaRef. Method C (clipped direct)Ref. Method F (in free air or on a perforated cable tray, horizontal or vertical)
TouchingTouchingSpaced by on cable diameter
2 cables, single-phase a.c. or d.c. flat3 or 4 cables, three-phase a.c. flat2 cables, single-phase a.c. or d.c. flat3 or 4 cables, three-phase a.c. flat3 cables three-phase a.c. trefoil2 cables, d.c.2 cables, single-phase a.c.3 or 4 cables, three-phase a.c.
HorizontalVerticalHorizontalVerticalHorizontalVertical
123456789101112
mm²AAAAAAAAAAA
50237220253232222284270282266288266
70303277322293285356349357337358331
95367333389352346446426436412425393
120425383449405402519497504477485449
150488437516462463600575566539549510
185557496587524529688660643614618574
240656579689612625815782749714715666
300755662792700720943906842805810755
40085371789976781511371094929889848797
5009627911016851918131412661032989923871

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E3B

Conductor cross-sectional area2 cables d.c.Ref. Methods C&F (clipped direct, on trays or in free air)
2 cables, single-phase a.c.3 or 4 cables, three-phase a.c.
TouchingSpaced*Trefoil and touchingFlat and touchingFlat and spaced*
1234567
mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m


rxzrxzrxzrxzrxz
500.980.990.211.000.980.291.000.860.1800.870.840.250.880.840.330.90
700.670.680.200.710.690.290.750.590.1700.620.600.250.650.620.320.70
950.490.510.1950.550.530.280.600.440.1700.470.460.240.520.490.310.58
1200.390.410.1900.450.430.270.510.350.1650.390.380.340.440.410.300.51
1500.310.330.1850.380.360.270.450.290.1600.330.310.230.390.340.390.45
1850.250.270.1850.330.300.260.400.230.1600.280.260.230.340.290.290.41
2400.1950.210.1800.280.240.260.350.1800.1550.240.210.220.300.240.280.37
3000.1550.170.1750.250.1950.250.320.1450.1500.210.1700.220.280.200.270.34
4000.1150.1450.1700.220.1800.240.300.1250.1500.1950.1600.210.270.200.270.33
5000.0930.1250.1700.210.1650.240.290.1050.1450.1800.1450.200.250.1900.240.31

Note : *Spacings larger than one cable diameter will result in a large voltage drop.

r = conductor resistance at operating temperature

x = reactance

z = impedance

KEY FEATURES


- Manufactured according to IEC 60502-1 requirements

- 600/1000V voltage rating

- Single core power cable construction

- XLPE insulated conductor

- LSZH / LSOH outer sheath

- Armoured cable design

- Low smoke zero halogen sheath performance

- Suitable for fixed low voltage power distribution

- Suitable for underground and outdoor installation

- Suitable for public buildings and transport systems

- Provides improved mechanical protection



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Conductor size

- Conductor material

- Armour type

- Cable length

- Sheath colour

- Fire performance requirement

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


600/1000V single core XLPE LSZH armoured cable

is commonly selected for projects requiring

mechanical protection and LSZH performance.


It is suitable for underground cable routes,

transport systems, public buildings,

industrial plants and infrastructure projects.



RELATED CABLE TYPES


- IEC 60502 low voltage cable

- XLPE insulated LSZH sheathed cable

- Single core XLPE LSZH armoured cable

- Multi-core XLPE LSZH armoured cable

- XLPE LSZH unarmoured cable

- XLPE PVC armoured cable

- BS6724 LSZH armoured cable

- BS5467 armoured power cable

- 600/1000V power cable

- Low voltage power cable



FAQ


What is this cable used for?


It is used for fixed low voltage

power distribution.


It is suitable for public buildings,

transport systems, underground routes

and infrastructure projects.



What standard does this cable follow?


This cable is designed according to

IEC 60502-1 requirements.



Is this cable armoured?


Yes. This is an armoured cable.


The armour provides improved

mechanical protection.



What does LSZH mean?


LSZH means Low Smoke Zero Halogen.


The sheath helps reduce smoke emission

and corrosive gas release during fire.



Can this cable be used underground?


Yes. It can be used for underground

cable routes and cable trenches.


The final installation should follow

project specifications and local

installation requirements.



What is special for single core

armoured cable?


For single core armoured cable,

the armour type should be selected

according to project requirements.


Non-magnetic armour may be required

for some AC applications.



What information is required for quotation?


Please confirm voltage rating,

conductor size, conductor material,

armour type and cable length.


Fire performance requirement,

installation method and destination port

are also required.



Can BURYCABLE supply IEC 60502

single core XLPE LSZH armoured cable?


Yes. BURYCABLE can supply IEC 60502-1

single core XLPE insulated LSZH sheathed

armoured cables.


We can support different conductor sizes,

armour types, sheath colours,

lengths and packing requirements.