Medium voltage XLPE insulated
steel wire armoured cable is designed
for medium voltage power distribution systems.
It is suitable for substations,
power supply stations, industrial plants,
switchboards and utility networks.
The XLPE insulation provides reliable
electrical performance and thermal stability.
The steel wire armour provides improved
mechanical protection and tensile strength.
It is suitable for cable ducts,
cable trenches, underground routes,
cable trays and protected outdoor installation.
This cable is commonly selected for
industrial and utility power networks.
The cable should be selected according to
voltage rating, conductor size,
screening structure, armour type,
installation method and project specification.
IEC 60228
IEC 60502-2
Conductor : Stranded bare copper (class 2)
Condutor screen : This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen.
Insulation : XLPE
Insulation screen : This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.
Core identification
1 Core : Natural
3 Cores : Black, Green, Brown
Inner sheath : PVC
Armor : Galvanized steel wires or aluminum wires for 1 core cable
Outer sheath : Special PVC. Color: red. U.V resistance can be offered upon request.
Fire retardance : IEC 60332-3-22
Operating temperature : -20~60°C
Max. conductor operating temperature : 90°C
Chemical resistance : Aliphatic and aromatic hydrocarbon resistance
| Conductor Corss-section | Diameter over Insulation | Diameter over Screen | Diameter over Inner Sheath | Diameter over Armor | Min. O.D. | Max. O.D. | Approx. Weight | Rated Voltage Uo/U(Um) |
|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | kg/km | kv |
| 25 | 12.3 | 13.7 | 17.7 | 21.5 | 31.5 | 34.8 | 1621 | 3.6 / 6 (7.2) |
| 35 | 13.3 | 14.7 | 18.7 | 22.5 | 32.5 | 35.8 | 1781 | 3.6 / 6 (7.2) |
| 50 | 14.4 | 15.8 | 19.8 | 23.6 | 33.6 | 37.0 | 1953 | 3.6 / 6 (7.2) |
| 70 | 16.0 | 17.4 | 21.4 | 25.2 | 35.1 | 38.7 | 2247 | 3.6 / 6 (7.2) |
| 95 | 17.55 | 19.0 | 23.0 | 26.8 | 36.7 | 40.4 | 2589 | 3.6 / 6 (7.2) |
| 120 | 19.06 | 20.5 | 24.5 | 28.3 | 38.1 | 42.1 | 2904 | 3.6 / 6 (7.2) |
| 150 | 20.37 | 21.8 | 25.8 | 29.6 | 39.4 | 43.4 | 3233 | 3.6 / 6 (7.2) |
| 185 | 22.05 | 23.5 | 27.5 | 31.3 | 41.0 | 45.3 | 3681 | 3.6 / 6 (7.2) |
| 240 | 24.6 | 26.0 | 30.0 | 33.8 | 43.5 | 47.9 | 4365 | 3.6 / 6 (7.2) |
| 300 | 27.4 | 28.8 | 32.8 | 36.6 | 46.2 | 50.9 | 5121 | 3.6 / 6 (7.2) |
| 400 | 30.9 | 32.3 | 36.3 | 40.1 | 49.6 | 54.7 | 6174 | 3.6 / 6 (7.2) |
| 500 | 35.4 | 36.8 | 40.8 | 45.8 | 55.3 | 61.0 | 7735 | 3.6 / 6 (7.2) |
| 630 | 39.8 | 41.2 | 45.3 | 50.3 | 60.0 | 66.2 | 9419 | 3.6 / 6 (7.2) |
| 25 | 14.1 | 15.5 | 19.5 | 23.3 | 33.3 | 36.7 | 1764 | 6 / 10 (12) |
| 35 | 15.1 | 16.5 | 20.5 | 24.3 | 34.2 | 37.8 | 1925 | 6 / 10 (12) |
| 50 | 16.2 | 17.6 | 21.6 | 25.4 | 35.3 | 38.9 | 2107 | 6 / 10 (12) |
| 70 | 17.8 | 19.2 | 23.2 | 27.0 | 36.9 | 40.7 | 2404 | 6 / 10 (12) |
| 95 | 19.35 | 20.8 | 24.8 | 28.6 | 38.4 | 42.4 | 2748 | 6 / 10 (12) |
| 120 | 20.86 | 22.3 | 26.3 | 30.1 | 39.9 | 44.0 | 3073 | 6 / 10 (12) |
| 150 | 22.17 | 23.6 | 27.6 | 31.4 | 41.1 | 45.4 | 3405 | 6 / 10 (12) |
| 185 | 23.85 | 25.3 | 29.3 | 33.1 | 42.8 | 47.2 | 3854 | 6 / 10 (12) |
| 240 | 26.2 | 27.6 | 31.6 | 35.4 | 45.0 | 49.6 | 4531 | 6 / 10 (12) |
| 300 | 28.6 | 30.0 | 34.0 | 37.8 | 47.3 | 52.2 | 5249 | 6 / 10 (12) |
| 400 | 31.7 | 33.1 | 37.1 | 40.9 | 50.3 | 55.5 | 6267 | 6 / 10 (12) |
| 500 | 35.8 | 37.2 | 41.2 | 46.2 | 55.7 | 61.4 | 7791 | 6 / 10 (12) |
| 630 | 40.2 | 41.6 | 45.7 | 50.7 | 60.4 | 66.7 | 9464 | 6 / 10 (12) |
| 25 | 16.3 | 17.7 | 21.7 | 25.5 | 35.4 | 39.1 | 1955 | 8.7 / 15 (17.5) |
| 35 | 17.3 | 18.7 | 22.7 | 26.5 | 36.4 | 40.1 | 2112 | 8.7 / 15 (17.5) |
| 50 | 18.4 | 19.8 | 23.8 | 27.6 | 37.4 | 41.3 | 2305 | 8.7 / 15 (17.5) |
| 70 | 20.0 | 21.4 | 25.4 | 29.2 | 39.0 | 43.0 | 2608 | 8.7 / 15 (17.5) |
| 95 | 21.55 | 23.0 | 27.0 | 30.8 | 40.5 | 44.7 | 2950 | 8.7 / 15 (17.5) |
| 120 | 23.06 | 24.5 | 28.5 | 32.3 | 42.0 | 46.3 | 3288 | 8.7 / 15 (17.5) |
| 150 | 24.37 | 25.8 | 29.8 | 33.6 | 43.3 | 47.7 | 3623 | 8.7 / 15 (17.5) |
| 185 | 26.05 | 27.5 | 31.5 | 35.3 | 44.9 | 49.5 | 4081 | 8.7 / 15 (17.5) |
| 240 | 28.4 | 29.8 | 33.8 | 37.6 | 47.1 | 52.0 | 4756 | 8.7 / 15 (17.5) |
| 300 | 30.8 | 32.2 | 36.2 | 40.0 | 49.5 | 54.6 | 5478 | 8.7 / 15 (17.5) |
| 400 | 33.9 | 35.3 | 39.3 | 44.3 | 53.8 | 59.4 | 6738 | 8.7 / 15 (17.5) |
| 500 | 38.0 | 39.4 | 43.4 | 48.4 | 58.0 | 64.0 | 8091 | 8.7 / 15 (17.5) |
| 630 | 42.4 | 43.8 | 47.9 | 52.9 | 62.8 | 69.2 | 9793 | 8.7 / 15 (17.5) |
| 35 | 19.3 | 20.7 | 24.7 | 28.5 | 38.3 | 42.3 | 2287 | 12 / 20 (24) |
| 50 | 20.4 | 21.8 | 25.8 | 29.6 | 39.4 | 43.4 | 2485 | 12 / 20 (24) |
| 70 | 22.0 | 23.4 | 27.4 | 31.2 | 40.9 | 45.2 | 2795 | 12 / 20 (24) |
| 95 | 23.55 | 25.0 | 29.0 | 32.8 | 42.5 | 46.9 | 3139 | 12 / 20 (24) |
| 120 | 25.06 | 26.5 | 30.5 | 34.3 | 43.9 | 48.5 | 3482 | 12 / 20 (24) |
| 150 | 26.37 | 27.8 | 31.8 | 35.6 | 45.2 | 49.9 | 3824 | 12 / 20 (24) |
| 185 | 28.05 | 29.5 | 33.5 | 37.3 | 46.9 | 51.7 | 4287 | 12 / 20 (24) |
| 240 | 30.4 | 31.8 | 35.8 | 39.6 | 49.1 | 54.1 | 4974 | 12 / 20 (24) |
| 300 | 32.8 | 34.2 | 38.2 | 42.0 | 51.6 | 56.9 | 5734 | 12 / 20 (24) |
| 400 | 35.9 | 37.3 | 41.3 | 46.3 | 56.0 | 61.7 | 6994 | 12 / 20 (24) |
| 500 | 40.0 | 41.4 | 45.5 | 50.5 | 60.2 | 66.4 | 8392 | 12 / 20 (24) |
| 630 | 44.4 | 45.8 | 49.9 | 54.9 | 64.9 | 71.6 | 10119 | 12 / 20 (24) |
| 25 | 26.3 | 27.7 | 31.7 | 35.5 | 45.1 | 49.8 | 2866 | 18 / 30 (36) |
| 50 | 25.4 | 26.8 | 30.8 | 34.6 | 44.2 | 48.8 | 2969 | 18 / 30 (36) |
| 70 | 27.0 | 28.4 | 32.4 | 36.2 | 45.8 | 50.5 | 3309 | 18 / 30 (36) |
| 95 | 28.8 | 30.2 | 34.0 | 37.8 | 47.3 | 52.2 | 3660 | 18 / 30 (36) |
| 120 | 30.06 | 31.5 | 35.5 | 39.3 | 48.8 | 53.8 | 4007 | 18 / 30 (36) |
| 150 | 31.37 | 32.8 | 36.8 | 40.6 | 50.1 | 55.2 | 4354 | 18 / 30 (36) |
| 185 | 33.05 | 34.5 | 38.5 | 43.5 | 53.1 | 58.5 | 5060 | 18 / 30 (36) |
| 240 | 35.4 | 36.8 | 40.8 | 45.8 | 55.5 | 61.2 | 5801 | 18 / 30 (36) |
| 300 | 37.8 | 39.2 | 43.2 | 48.2 | 58.0 | 64.0 | 6621 | 18 / 30 (36) |
| 400 | 40.9 | 42.3 | 46.4 | 51.4 | 61.3 | 67.6 | 7701 | 18 / 30 (36) |
| 500 | 45.0 | 46.4 | 50.5 | 55.5 | 65.5 | 72.2 | 9130 | 18 / 30 (36) |
| Conductor Corss-section | Diameter over Insulation | Diameter over Screen | Diameter over Inner Sheath | Diameter over Armor | Min. O.D. | Max. O.D. | Approx. Weight | Rated Voltage Uo/U(Um) |
|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | kg/km | kv |
| 25 | 12.3 | 13.7 | 36.7 | 40.7 | 46.3 | 51.0 | 4418 | 3.6 / 6 (7.2) |
| 35 | 13.3 | 14.7 | 38.9 | 42.9 | 48.4 | 53.4 | 4944 | 3.6 / 6 (7.2) |
| 50 | 14.4 | 15.8 | 41.4 | 46.4 | 51.8 | 57.1 | 5995 | 3.6 / 6 (7.2) |
| 70 | 16.0 | 17.4 | 44.9 | 49.9 | 55.2 | 60.9 | 7012 | 3.6 / 6 (7.2) |
| 95 | 17.55 | 19.0 | 48.4 | 53.4 | 58.6 | 64.6 | 8226 | 3.6 / 6 (7.2) |
| 120 | 19.06 | 20.5 | 51.7 | 56.7 | 61.8 | 68.2 | 9357 | 3.6 / 6 (7.2) |
| 150 | 20.37 | 21.8 | 54.6 | 59.6 | 64.6 | 71.3 | 10528 | 3.6 / 6 (7.2) |
| 185 | 22.05 | 23.5 | 58.3 | 63.3 | 68.2 | 75.2 | 12064 | 3.6 / 6 (7.2) |
| 240 | 24.6 | 26.0 | 63.8 | 68.8 | 73.5 | 81.1 | 14480 | 3.6 / 6 (7.2) |
| 300 | 27.4 | 28.8 | 70.0 | 77.5 | 82.4 | 90.8 | 18262 | 3.6 / 6 (7.2) |
| 25 | 14.1 | 15.5 | 40.7 | 44.7 | 50.1 | 55.3 | 4961 | 6 / 10 (12) |
| 35 | 15.1 | 16.5 | 42.9 | 47.9 | 53.3 | 58.7 | 5954 | 6 / 10 (12) |
| 50 | 16.2 | 17.6 | 45.3 | 50.3 | 55.6 | 61.3 | 6634 | 6 / 10 (12) |
| 70 | 17.8 | 19.2 | 48.8 | 53.8 | 59.0 | 65.1 | 7674 | 6 / 10 (12) |
| 95 | 19.35 | 20.8 | 52.4 | 57.4 | 62.5 | 68.9 | 8913 | 6 / 10 (12) |
| 120 | 20.86 | 22.3 | 55.7 | 60.7 | 65.7 | 72.4 | 10084 | 6 / 10 (12) |
| 150 | 22.17 | 23.6 | 58.5 | 63.5 | 68.4 | 75.4 | 11273 | 6 / 10 (12) |
| 185 | 23.85 | 25.3 | 62.3 | 67.3 | 72.1 | 79.5 | 12828 | 6 / 10 (12) |
| 240 | 26.2 | 27.6 | 67.3 | 73.6 | 79.5 | 87.7 | 16365 | 6 / 10 (12) |
| 300 | 28.6 | 30.0 | 72.6 | 80.1 | 84.9 | 93.6 | 18919 | 6 / 10 (12) |
| 25 | 16.3 | 17.7 | 45.5 | 50.5 | 55.8 | 61.5 | 6149 | 8.7 / 15 (17.5) |
| 35 | 17.3 | 18.7 | 47.7 | 52.7 | 57.9 | 63.9 | 6755 | 8.7 / 15 (17.5) |
| 50 | 18.4 | 19.8 | 50.2 | 55.2 | 60.3 | 66.6 | 7457 | 8.7 / 15 (17.5) |
| 70 | 20.0 | 21.4 | 53.7 | 58.7 | 63.7 | 70.3 | 8532 | 8.7 / 15 (17.5) |
| 95 | 21.55 | 23.0 | 57.2 | 62.2 | 67.1 | 74.0 | 9805 | 8.7 / 15 (17.5) |
| 120 | 23.06 | 24.5 | 60.5 | 65.5 | 70.3 | 77.6 | 11004 | 8.7 / 15 (17.5) |
| 150 | 24.37 | 25.8 | 63.4 | 68.4 | 73.1 | 80.7 | 12217 | 8.7 / 15 (17.5) |
| 185 | 26.05 | 27.5 | 67.1 | 73.4 | 79.3 | 87.5 | 14993 | 8.7 / 15 (17.5) |
| 240 | 28.4 | 29.8 | 72.2 | 78.5 | 84.7 | 93.4 | 17580 | 8.7 / 15 (17.5) |
| 300 | 30.8 | 32.2 | 77.4 | 83.7 | 89.9 | 99.2 | 20280 | 8.7 / 15 (17.5) |
| 35 | 19.3 | 20.7 | 52.1 | 57.1 | 62.2 | 68.6 | 7537 | 12 / 20 (24) |
| 50 | 20.4 | 21.8 | 54.6 | 59.6 | 64.6 | 71.3 | 8261 | 12 / 20 (24) |
| 70 | 22.0 | 23.4 | 58.1 | 63.1 | 68.0 | 75.0 | 9373 | 12 / 20 (24) |
| 95 | 23.55 | 25.0 | 61.6 | 66.6 | 71.4 | 78.8 | 10627 | 12 / 20 (24) |
| 120 | 25.06 | 26.5 | 64.9 | 69.9 | 74.6 | 82.3 | 11895 | 12 / 20 (24) |
| 150 | 26.37 | 27.8 | 67.8 | 74.1 | 80.0 | 88.3 | 14306 | 12 / 20 (24) |
| 185 | 28.05 | 29.5 | 71.5 | 77.8 | 83.8 | 92.4 | 16021 | 12 / 20 (24) |
| 240 | 30.4 | 31.8 | 76.6 | 82.9 | 89.1 | 98.3 | 18645 | 12 / 20 (24) |
| 50 | 25.4 | 26.8 | 65.6 | 71.9 | 77.9 | 85.9 | 11491 | 18 / 30 (36) |
| 70 | 27.0 | 28.4 | 69.1 | 75.4 | 81.5 | 89.9 | 12878 | 18 / 30 (36) |
| 95 | 28.55 | 30.0 | 72.6 | 78.9 | 85.1 | 93.8 | 14252 | 18 / 30 (36) |
| 120 | 30.06 | 31.5 | 75.9 | 82.2 | 88.5 | 97.6 | 15708 | 18 / 30 (36) |
| 150 | 31.37 | 32.8 | 78.8 | 85.1 | 91.5 | 100.9 | 17092 | 18 / 30 (36) |
| 185 | 33.05 | 34.5 | 82.5 | 88.8 | 95.3 | 105.1 | 18901 | 18 / 30 (36) |
| 240 | 35.4 | 36.8 | 87.6 | 95.1 | 101.0 | 111.0 | 21499 | 18 / 30 (36) |
KEY FEATURES
- Designed according to IEC 60502-2 requirements
- Medium voltage power cable construction
- XLPE insulated conductors
- Steel wire armoured design
- Suitable for substations and power networks
- Suitable for industrial power distribution
- Suitable for cable trenches and ducts
- Suitable for underground installation
- Provides mechanical protection
- Commonly used in utility power systems
SELECTION NOTES
Before quotation, please confirm:
- Voltage rating
- Number of cores
- Conductor size
- Conductor material
- Screen type
- Armour type
- Cable length
- Sheath colour
- Installation method
- Installation environment
- Required standard or project specification
- Packing requirement
- Destination port or delivery address
Medium voltage XLPE SWA cable
is commonly selected for industrial
and utility power distribution.
It is suitable where mechanical protection
and tensile protection are required.
RELATED CABLE TYPES
- IEC 60502-2 medium voltage cable
- MV XLPE insulated cable
- Steel wire armoured cable
- SWA cable
- Overall screened MV cable
- Lead sheathed MV cable
- GSTA medium voltage cable
- Medium voltage underground cable
- MV power cable
- Utility power cable
FAQ
What is this cable used for?
It is used for medium voltage
power distribution.
It is suitable for substations,
power supply stations, industrial plants
and underground cable routes.
What standard does this cable follow?
This cable is designed according to
IEC 60502-2 requirements.
Is this cable armoured?
Yes. This cable has steel wire armour.
The armour provides improved
mechanical protection and tensile strength.
What is SWA armour?
SWA means steel wire armour.
It is commonly used where mechanical
and tensile protection are required.
Does this cable have lead cover?
No. This page is for XLPE insulated
steel wire armoured cable.
It is not a lead sheathed cable.
Is this cable overall screened?
No. This page is not the overall screened type.
If overall screen is required,
please confirm it in the project specification.
Can this cable be used underground?
Yes. It can be used for underground
cable routes and cable trenches.
The final installation should follow
project specifications and local
installation requirements.
What information is required for quotation?
Please confirm voltage rating,
number of cores, conductor size,
screen type and cable length.
Armour type, installation method
and destination port are also required.
Can BURYCABLE supply IEC 60502-2
medium voltage SWA cable?
Yes. BURYCABLE can supply IEC 60502-2
medium voltage XLPE insulated
steel wire armoured cables.
We can support different voltage ratings,
conductor sizes, screen structures,
armour types and packing requirements.