whatsapp
backtop
600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables to IEC 60502 (2-5 Cores & Multicore)
600/1000V XLPE insulated PVC sheathed armoured cable to IEC 60502-1 is designed for low voltage power distribution, underground installation, industrial plants and infrastructure projects.
600_1000V XLPE Insulated, PVC Sheathed, Armoured PowerCables to IEC 60502 (2-5&Multicore).pdf Contact us

APPLICATION

This series of flame-retardant and fire-resistant cables is specifically designed for harsh environments, making it suitable for critical locations such as power plants, metro systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings. The product strictly complies with the international standard IEC 60502-1 and has passed the IEC 60332-1 vertical flame test, ensuring effective flame resistance in the event of a fire. With a rated voltage of 600/1000V, it meets various power transmission requirements.

600/1000V XLPE insulated PVC sheathed armoured cable is designed for fixed low voltage power distribution.


It is suitable for industrial plants, power stations, commercial buildings, infrastructure projects, substations and general electrical installations.


The XLPE insulation provides reliable electrical performance and thermal stability for low voltage power circuits.


The metallic armour provides mechanical protection, making the cable suitable for demanding installation environments.


The PVC outer sheath provides general protection against moisture, abrasion and normal installation conditions.


Typical applications include underground cable routes, cable trenches, cable ducts, outdoor installation, plant rooms and protected power distribution systems.


The cable should be selected according to voltage rating, number of cores, conductor size, armour type, installation method and project specification.



STANDARDS

Basic design adapted to IEC 60502-1

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)IEC 60332-1

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

ConductorAnnealed copper wire, stranded according to IEC 60228 class 2.
InsulationXLPE according to IEC 60502-1.
Inner CoveringExtruded PVC or polymeric compound.
ArmouringGalvanized steel wire
Outer SheathExtruded PVC Type ST1/ST2 according to IEC 60502-1.
Outer Sheath OptionUV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

COLOUR CODE

Insulation ColourTwo-core: Brown, blue
Three-core: Brown, black, grey
Four-core: Blue, brown, black, grey
Five-core: Green-and-yellow, blue, brown, black, grey
Other colours can be offered upon request.
Sheath ColourBlack, other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation80°C (For ST1 Sheath); 90°C (For ST2 Sheath)
Maximum short circuit temperature (5 Seconds)250°C
Minimum bending radius12 x Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP600-RVMV-R
No. of Cores x Cross SectionClass of ConductorNominal
Insulation Thickness 
Nominal Inner
Covering Thickness
Nominal
Armour Wire Diameter
Nominal
Sheath Thickness
Nominal
Overall Diameter
Approx. Weight
No.xmm2 mm mmmm mmkg/km
2 Cores
2x1.520.71.00.91.813.2325
2x2.520.71.00.91.814.0372
2x4.020.71.00.91.815.1438
2x6.020.71.01.251.817.1645
2x1020.71.01.251.819.0806
2x1620.71.01.251.821.11015
2x2520.91.01.61.825.21517
2x3520.91.01.61.827.51830
2x5021.01.01.61.930.82259
2x7021.11.02.02.035.83182
2x9521.11.22.02.140.24022
2x12021.21.22.02.344.24810
2x15021.41.22.52.449.36120
2x18521.61.42.52.654.77375
2x24021.71.42.52.760.59037
2x30021.81.62.52.966.610871
2x40022.01.62.53.173.713256
3 Cores
3x1.520.71.00.91.813.6361
3x2.520.71.00.91.814.5420
3x4.020.71.00.91.815.7505
3x6.020.71.01.251.817.8742
3x1020.71.01.251.819.8954
3x1620.71.01.251.822.11231
3x2520.91.01.61.826.51857
3x3520.91.01.61.829.02281
3x5021.01.01.61.932.52856
3x7021.11.02.02.138.04056
3x9521.11.22.02.242.75196
3x12021.21.22.02.346.86247
3x15021.41.42.52.552.88000
3x18521.61.42.52.758.19626
3x24021.71.42.52.864.311939
3x30021.81.62.53.070.814468
3x40022.01.63.23.380.018832
3 Cores+1 Earth Conductor


power conductorearth  conductor




3x16/1020.70.71.01.61.822.71446
3x25/1620.90.71.01.61.826.51925
3x35/1620.90.71.01.61.929.02607
3x50/2521.00.91.01.62.133.03413
3x70/3521.10.91.22.02.238.04710
3x95/5021.11.01.22.02.342.46179
3x120/7021.21.11.22.02.548.08195
3x150/7021.41.11.42.52.752.010304
3x185/9521.61.11.42.52.857.213172
3x240/12021.71.21.62.53.164.016711
3x300/15021.81.41.62.53.269.821094
3x400/18522.01.61.63.23.678.627130
4 Cores
4x1.520.71.00.91.814.4406
4x2.520.71.00.91.815.4479
4x4.020.71.01.251.817.6718
4x6.020.71.01.251.819.0859
4x1020.71.01.251.821.31124
4x1620.71.01.61.824.51628
4x2520.91.01.61.828.62237
4x3520.91.01.61.931.62794
4x5021.01.02.02.136.53813
4x7021.11.22.02.241.95065
4x9521.11.22.02.346.76463
4x12021.21.42.52.552.98401
4x15021.41.42.52.758.09987
4x18521.61.42.52.863.712040
4x24021.71.62.53.171.515186
4x30021.81.62.53.278.018316
4x40022.01.83.23.688.723930
5 Cores
5x1.520.71.00.91.815.5467
5x2.520.71.00.91.816.6558
5x4.020.71.00.91.818.1692
5x6.020.71.01.251.820.3972
5x1020.71.01.251.822.81300
5x1620.71.01.61.826.41899
5x2520.91.01.61.931.22671
5x3520.91.01.62.034.53371
Multicore
7C1.520.71.00.91.816.4540
8C1.520.71.00.91.818.0692
10C1.520.71.01.251.820.1819
12C1.520.71.01.251.820.5882
19C1.520.71.01.251.823.11137
27C1.520.71.01.61.827.21618
37C1.520.71.01.61.829.71958
48C1.520.71.01.61.933.42378
7C2.520.71.01.251.817.6657
8C2.520.71.01.251.819.4834
10C2.520.71.01.251.821.7995
12C2.520.71.01.251.822.31082
19C2.520.71.01.61.825.21428
27C2.520.71.01.61.829.82033
37C2.520.71.01.61.832.72499
48C2.520.71.02.01.936.83063

Note: Other conductor sizes & core configurations are available upon request.

ELECTRICAL PROPERTIES

Conductor Operating Temperature90°C
Ambient Temperature30°C

Current-Carrying Capacities (Amp) according to BS7671:2008 table 4E4A

Conductor crosssectional
area
Reference Method C (clipped direct)Reference Method E (in free air
or on a perforated cable tray,
horizontal or vertical)
Reference Method D (direct in in
groud or in ducting in groud. in or
around buildings)
1 two-core cable*,
single-phase a.c.
or d.c.
1 three-or four
core cable*,
three-phase a.c.
1 two-core
cable*, singlephase
a.c. or
d.c.
1 three-or four
core cable*,
three-phase a.c.
1 two-core cable*,
single-phase a.c.
or d.c.
1 three-or four
core cable*, threephase
a.c.
1234567
mm2AAAAAA
1.5272329252521
2.5363139333328
4.0494252444336
6.0625366565344
10857390787158
1611094115999175
2514612415213111696
35180154188162139115
50219187228197164135
70279238291251203167
95338289354304239197
120392335410353271223
150451386472406306251
185515441539463343281
240607520636546395324
300698599732628446365
400787673847728--

Voltage Drop (Per Amp Per Meter) according to BS 7671: 2008 table 4E4B

Conductor cross- sectional areaTwo-core cables, d.c.Two-core cable, single-phase a.c.Three-or four core cable, three-phase a.c.
1234
mm2mV/A/mmV/A/mmV/A/m
1.5313127
2.5191916
4.0121210
6.07.97.96.8
104.74.74.0
162.92.92.5


rxzrxz
251.851.850.1601.901.600.1401.65
351.351.350.1551.351.150.1351.15
500.980.990.1551.000.860.1350.87
700.670.670.1500.690.590.1300.60
950.490.500.1500.520.430.1300.45
1200.390.400.1450.420.340.1300.37
1500.310.320.1450.350.380.1250.30
1850.250.260.1450.290.220.1250.26
2400.1950.2000.1400.240.1750.1250.21
3000.1550.1600.1400.210.1400.1200.185
4000.1200.1300.1400.1900.1150.1200.165

Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance

KEY FEATURES


- Manufactured according to IEC 60502-1 requirements

- 600/1000V voltage rating

- XLPE insulated conductors

- PVC outer sheath

- Armoured cable construction

- Suitable for fixed low voltage power distribution

- Suitable for underground and outdoor installation

- Suitable for industrial and infrastructure projects

- Provides improved mechanical protection

- Commonly used in demanding power cable installations



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Number of cores

- Conductor size

- Conductor material

- Armour type

- Cable length

- Sheath colour

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


600/1000V XLPE insulated PVC sheathed armoured cable is commonly selected for low voltage power distribution where mechanical protection is required.


It is suitable for industrial plants, underground cable routes, outdoor installation and infrastructure power systems.



RELATED CABLE TYPES


- IEC 60502 low voltage cable

- XLPE PVC armoured cable

- XLPE SWA PVC cable

- XLPE PVC unarmoured cable

- BS5467 armoured power cable

- BS6724 LSZH armoured cable

- BS7889 unarmoured power cable

- 600/1000V power cable

- Low voltage power cable

- Underground power cable



FAQ


What is this 600/1000V XLPE PVC armoured cable used for?


This cable is used for fixed low voltage power distribution.


It is suitable for industrial plants, infrastructure projects, underground cable routes, outdoor installation and protected power systems.



What standard does this cable follow?


This cable is designed according to IEC 60502-1 requirements.



Is this cable armoured?


Yes. This cable has an armoured construction to provide improved mechanical protection.



Can this cable be used underground?


Yes. Armoured construction makes it suitable for underground cable routes, cable trenches and demanding installation environments, subject to project specification and local installation requirements.



Can BURYCABLE supply IEC 60502 armoured power cable?


Yes. BURYCABLE can supply IEC 60502-1 XLPE insulated PVC sheathed armoured cables according to project voltage, core number, conductor size, armour type, length and packing requirements.