600/1000V Multi-Core XLPE Insulated LSZH Sheathed Unarmoured Cable to IEC 60502-1
600/1000V multi-core XLPE insulated LSZH sheathedunarmoured cable to IEC 60502-1.Suitable for fixed low voltage power distribution,public buildings, industrial plantsand protected cable routes.
600_1000V XLPE Insulated,LSZH Sheathed Power Cables to IEC 60502-1 (2-5 Cores & Multicore).pdf Contact us

APPLICATION

600/1000V multi-core XLPE insulated

LSZH sheathed unarmoured cable is designed

for fixed low voltage power distribution.


It is suitable for industrial plants,

commercial buildings, public buildings,

equipment connections and infrastructure projects.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH sheath helps reduce smoke emission

and corrosive gas release in the event of fire.


As an unarmoured cable, it does not provide

metallic mechanical protection.


It is suitable for cable trays, cable ducts,

conduit, trunking and protected cable routes.


It is not recommended for direct burial

without additional mechanical protection.


The cable should be selected according to

voltage rating, number of cores,

conductor size, fire performance requirement,

installation method and project specification.


STANDARDS

Basic design to IEC 60502-1

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor : The conductors shall be class 2 plain or metal-coated annealed copper in accordance with IEC 60228. Class 1 and class 5 conductor can be offered as option.

Insulation : Thermosetting XLPE material and thickness shall be as per IEC 60502-1.

Outer Sheath : Thermoplastic halogen free compound ST8 as per IEC 60502-1.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour2-coreBrown and blue.
3-coreBrown, black and grey.
4-coreBlue, brown black and grey.
5-coreGreen and yellow, blue, brown black, grey.
Above 5 CoresBlack cores with white numerals.
Other colours can be offered upon request.
Sheath ColourBlack; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius :

circular copper conductors OD≤25mm : 4 × Overall Diameter

circular copper conductors OD﹥25mm : 6 × Overall Diameter

shaped copper conductors : 8 × Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP600-RZ1-R
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessNominal Sheath ThicknessApprox. Overall DiameterApprox. Weight
No.×mm² mmmmmmkg/km
2 Cores
2×1.520.71.89.2117
2×2.520.71.810.0146
2×420.71.811.0190
2×620.71.812.0244
2×1020.71.813.6349
2×1620.71.815.4495
2×2520.91.818.4735
2×3520.91.820.6963
2×5021.01.823.61261
2×7021.11.826.81751
2×9521.11.930.22359
2×12021.22.033.72950
2×15021.42.237.53633
2×18521.62.341.64523
2×24021.72.546.75877
2×30021.82.651.47285
2×400222.958.99294
3 cores
3×1.520.71.89.6143
3×2.520.71.810.5183
3×420.71.811.6244
3×620.71.812.6321
3×1020.71.814.4472
3×1620.71.816.3681
3×2520.91.819.51027
3×3520.91.821.91360
3×5021.01.825.11795
3×7021.11.928.72530
3×9521.12.032.43441
3×12021.22.136.14307
3×15021.42.340.35276
3×18521.62.444.66607
3×24021.72.650.28593
3×30021.82.755.210668
3×40022.03.063.313570
3 cores + 1 core earth conductor


3 cores1 core


3×16/1020.70.71.818.3792
3×25/1620.90.71.822.11201
3×35/1620.90.71.824.71533
3×50/2521.00.91.828.22069
3×70/3521.10.92.033.12906
3×95/5021.11.02.137.63949
3×120/7021.21.12.342.05036
3×150/7021.41.12.446.66005
3×185/9521.61.12.652.27608
3×240/12021.71.22.859.09856
3×300/15021.81.43.065.212224
3×400/18522.01.63.273.215523
4 cores
4×1.520.71.810.4172
4×2.520.71.811.3223
4×420.71.812.5303
4×620.71.813.7402
4×1020.71.815.7599
4×1620.71.817.5873
4×2520.91.821.21328
4×3520.91.823.81767
4×5021.01.827.52339
4×7021.12.031.73326
4×9521.12.135.84505
4×12021.22.339.95669
4×15021.42.444.66948
4×18521.62.649.58701
4×24021.72.855.711322
4×30021.83.061.414105
4×40022.03.270.417943
Multicore
5×1.520.71.811.7212
5×2.520.71.812.8276
7×1.520.71.812.6264
7×2.520.71.813.8351
10×1.520.71.815.6360
10×2.520.71.817.2483
12×1.520.71.816.0408
12×2.520.71.817.8552
14×1.520.71.817.0459
14×2.520.71.818.7626
19×1.520.71.818.6585
19×2.520.71.820.7806
21×1.520.71.819.4638
21×2.520.71.821.7881
24×1.520.71.821.5724
24×2.520.71.824.11002
30×1.520.71.822.8866
30×2.520.71.825.51209
40×1.520.71.825.41108
40×2.520.71.928.71560
48×1.520.71.828.01307
48×2.520.71.931.61864
61×1.520.71.930.71631
61×2.520.72.034.72312

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E2A

Conductor cross-sectional areaRef. Method A (enclosed in conduit in thermally insulating wall etc.)Ref. Method B (enclosed in conduit on a wall or in trunking etc.)Ref. Method C (clipped direct)Ref. Method E (in free air or on a perforated cable tray etc. horizontal or vertical)
1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.1 two-core cable*, single-phase a.c. or d.c.1 three- or four-core cable*, three-phase a.c.
123456789
mm²AAAAAAAA
1.518.516.52219.524222623
2.52522302633303632
43330403545404942
64238514458526354
105751696080718675
167668918010796115100
259989119105138119149127
35121109146128171147185158
50145130175154209179225192
70183164221194269229289246
95220197265233328278352298
120253227305268382322410346
150290259334300441371473399
185329295384340506424542456
240386346459398599500641538
300442396532455693576741621
400--625536803667865741

Note: With or without a protective conductor.

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E2B

Conductor cross-sectional areaTwo-core cable, d.c.Two-core cable, single-phase a.c.Three- or four-core cable, three-phase a.c.
1234
mm²mV/A/mmV/A/mmV/A/m
1.5313127
2.5191916
4121210
67.97.96.8
104.74.74.0
162.92.92.5


rxzrxz
251.851.850.1601.901.600.1401.65
351.351.350.1551.351.150.1351.15
500.980.990.1551.000.860.1350.87
700.670.670.1500.690.590.1300.60
950.490.500.1500.520.430.1300.45
1200.390.400.1450.420.340.1300.37
1500.310.320.1450.350.280.1250.30
1850.250.260.1450.290.220.1250.26
2400.1950.2000.1400.240.1750.1250.21
3000.1550.1600.1400.210.1400.1200.185
4000.1200.1300.1400.1900.1150.1200.165

Note :

r = conductor resistance at operating temperature

x = reactance

z = impedance

KEY FEATURES


- Manufactured according to IEC 60502-1 requirements

- 600/1000V voltage rating

- Multi-core power cable construction

- XLPE insulated conductors

- LSZH / LSOH outer sheath

- Unarmoured cable design

- Low smoke zero halogen sheath performance

- Suitable for fixed low voltage power distribution

- Suitable for public buildings and industrial plants

- Commonly used in protected cable routes



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Number of cores

- Conductor size

- Conductor material

- Cable length

- Sheath colour

- Fire performance requirement

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


600/1000V multi-core XLPE LSZH unarmoured cable

is commonly selected for projects requiring

low smoke zero halogen performance.


It is suitable where mechanical protection

is provided by the installation system.



RELATED CABLE TYPES


- IEC 60502 low voltage cable

- XLPE insulated LSZH sheathed cable

- XLPE LSZH unarmoured cable

- XLPE LSZH armoured cable

- XLPE PVC unarmoured cable

- XLPE PVC armoured cable

- BS6724 LSZH armoured cable

- BS7211 LSZH cable

- 600/1000V power cable

- Low voltage power cable



FAQ


What is this cable used for?


It is used for fixed low voltage

power distribution.


It is suitable for public buildings,

industrial plants, equipment connections

and protected cable routes.



What standard does this cable follow?


This cable is designed according to

IEC 60502-1 requirements.



Is this cable armoured?


No. This is an unarmoured cable.


It does not have metallic armour protection.



What does LSZH mean?


LSZH means Low Smoke Zero Halogen.


The sheath helps reduce smoke emission

and corrosive gas release during fire.



Can this cable be used underground?


It is not recommended for direct burial

without additional mechanical protection.


For underground use, the installation method

should follow the project specification.



What is the difference between LSZH

and PVC sheath?


LSZH sheath provides better low smoke

and halogen-free performance.


PVC sheath is commonly used for

general low voltage applications.



What information is required for quotation?


Please confirm voltage rating,

number of cores, conductor size

and cable length.


Fire performance requirement,

installation method and destination port

are also required.



Can BURYCABLE supply IEC 60502

XLPE LSZH unarmoured cable?


Yes. BURYCABLE can supply IEC 60502-1

multi-core XLPE insulated LSZH sheathed

unarmoured cables.


We can support different core numbers,

conductor sizes, sheath colours,

lengths and packing requirements.