300/500V Single Core XLPE Insulated LSZH Sheathed Cable to BS7211
300/500V single core XLPE insulated LSZH sheathed cable to BS7211 is designed for fixed wiring in buildings, public facilities and indoor installations requiring low smoke zero halogen performance.
300_500V XLPE Insulated, LSZH Sheathed Power Cables to BS 7211 (Single Core).pdf Contact us

APPLICATION

300/500V single core XLPE insulated

LSZH sheathed cable to BS7211 is designed

for fixed wiring and low voltage

building installations.


It is suitable for commercial buildings,

public facilities, hospitals, airports,

schools, data centres and transport systems.


The cable is used where low smoke

zero halogen performance is required

to reduce smoke emission and corrosive gas

release in the event of fire.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The LSZH outer sheath provides low smoke

and halogen free performance for safer

indoor installation environments.


This cable is commonly used for lighting,

power, panel wiring and general fixed wiring

circuits in buildings.


As an unarmoured single core cable,

it should be installed where mechanical

protection is provided by conduit,

trunking, cable tray or other protected

wiring systems.


The cable should be selected according to

voltage rating, conductor size,

insulation colour, sheath colour,

installation method, fire performance

requirement and project specification.


STANDARDS

Basic design to BS 7211:2012

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen FreeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

300/500V

CABLE CONSTRUCTION

Conductor : Annealed copper conductor, solid according to BS EN 60228 class 1.

Insulation : XLPE type GP8 according to BS 7655-1.3. Crosslinked polyolefin material type EI 5 according to EN 50363-5 can be offered as option.

CPC (Circuit Protective Conductor) : Uninsulated copper conductor.

Outer Sheath : Extruded LSZH type LTS 2 according to BS 7655-6.1.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour : Brown or blue.

Sheath Colour : White; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius : 4 x Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFLP300-RZ1-U
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessCross- sectional Area of CPCClass of CPCNominal Insulation ThicknessMin. overall DimensionsMax. overall DimensionsApprox. Weight
No.×mm² mmmm² mmmmmmkg/km
1×1.010.701.010.94.1x5.25.0x6.345
1×1.510.701.010.94.4x5.45.3x6.655

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E1A

Conductor cross- ectional areaRef. Method A (enclosed in conduit in thermally insulating wall etc.)Ref. Method B (enclosed in conduit on a wall or in trunking etc.)Ref. Method C (clipped direct)
2 cables, single-phase a.c. or d.c.3 or 4 cables, three-phase a.c.2 cables, single-phase a.c. or d.c3 or 4 cables, three-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, three-phase a.c. flat and touching or trefoil
1234567
mm²AAAAAA
1.0141317151917.5
1.5191723202523

Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E1B

Conductor cross- sectional area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, three-phase a.c.
Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)
Cables touching, TrefoilCables touching, flatCables spaced*, flat
Cables touchingCables spaced*
123456789
mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m
1.04646464640404040
1.53131313127272727

Note: *Spacings larger than one cable diameter will result in a large voltage drop.

KEY FEATURES


- Designed according to BS7211 requirements

- 300/500V voltage rating

- Single core cable construction

- XLPE insulated conductor

- LSZH / LSOH outer sheath

- Low smoke zero halogen performance

- Suitable for fixed wiring installation

- Suitable for building wire applications

- Suitable for indoor protected cable routes

- Suitable for public buildings and commercial buildings



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Conductor size

- Cable length

- Insulation colour

- Sheath colour

- Installation method

- Fire performance requirement

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


BS7211 300/500V single core XLPE insulated

LSZH sheathed cable is commonly selected

for indoor fixed wiring where low smoke

zero halogen performance is required.


It is suitable for buildings and public

facilities where smoke emission and

corrosive gas release need to be reduced

in the event of fire.


For installations requiring mechanical

protection, the cable should be installed

in conduit, trunking, cable tray

or other protected routes.



RELATED CABLE TYPES


- BS7211 cable

- 6491B cable

- 2491B cable

- 6181B cable

- 6241B cable

- 6242B cable

- 6243B cable

- 450/750V BS7211 cable

- LSZH building wire

- Fixed wiring cable



FAQ


What is this BS7211 single core cable used for?


This cable is used for fixed wiring

and low voltage building installations.


It is suitable for commercial buildings,

public facilities, hospitals, airports,

schools, data centres and transport systems.



What is the voltage rating of this cable?


This page is for 300/500V

single core XLPE insulated LSZH sheathed

cable to BS7211.



Is this cable LSZH?


Yes. This cable uses an LSZH / LSOH

outer sheath to reduce smoke emission

and corrosive gas release in the event of fire.



Is this cable armoured?


No. This is an unarmoured single core

fixed wiring cable.


Where mechanical protection is required,

it should be installed in conduit,

trunking, cable tray or other protected routes.



Is BS7211 the same as BS6724?


No. BS7211 is generally used for

unarmoured LSZH building wiring cables.


BS6724 is normally used for LSZH

armoured power cables.



Can this cable be used outdoors?


It is mainly selected for indoor

and protected fixed wiring installations.


Outdoor use should be confirmed

according to project specification

and installation conditions.



What information is required for quotation?


Please confirm voltage rating,

conductor size, cable length,

insulation colour, sheath colour,

installation method and required standard.


Destination port or delivery address

is also required.



Can BURYCABLE supply BS7211

single core cable?


Yes. BURYCABLE can supply BS7211

single core XLPE insulated LSZH sheathed

cables according to project voltage,

conductor size, length, colour

and packing requirements.