Type A1, A2 & A3 LSZH Railway Signalling Cable
Type A railway signalling cables with class 2 tinned copper and crosslinked LSZH insulation. Choose unsheathed A1 single cores, sheathed A2 single cores or A3 multicore cables for equipment and relay-room wiring.
TYPE A1, A2 & A3Railway Signalling Cable.pdf Contact us

APPLICATION

Type A1, A2 and A3 cables serve fixed railway signalling wiring in relay rooms, signal boxes and equipment locations. All three use class 2 tinned copper with crosslinked LSZH insulation. A1 is an unsheathed single core, A2 adds an LSZH sheath to a single core, and A3 provides an LSZH-sheathed multicore construction. The choice depends on the wiring arrangement and the protection provided by the enclosure or route.

STANDARD

  • NR/PS/SIG/00005(formerly RT/E/PS/00005)

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Tinned stranded copper, class 2 according to IEC 60228 & BS 6360.

  • Insulation: LSZH crosslinked.

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Sheath: LSZH (for types A2 & A3 only).

Nominal Conductor Cross Sectionmm0.751.15
Maximum Conductor DC ResistanceΩ/km24.817.3
Voltage RatingKV0.65/1.1
Nominal Insulation Thicknessmm0.850.85

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 6×OD (static); 15×OD (dynamic)

  • Temperature Range:-25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm
No. & Nominal
Diameter of Strands
No/mm
Nominal Sheath
Thickness
mm
Overall Diameter
Min/Max
mm
Nominal
Weight
kg/km
Type A1(without sheath)
BRAIL A1-H-1G0.75(BL)1x0.75(blue)7/0.37-2.7/3.216
BRAIL A1-H-1G0.75(BR)1x0.75(brown)7/0.37-2.7/3.216
BRAIL A1-H-1G0.75(RD)1x0.75(red)7/0.37-2.7/3.216
BRAIL A1-H-1G0.75(OR)1x0.75(orange)7/0.37-2.7/3.216
BRAIL A1-H-1G0.75(GR)1x0.75(green)7/0.37-2.7/3.216
BRAIL A1-H-1G0.75(VI)1x0.75(violet)7/0.37-2.7/3.216
BRAIL A1-H-1G0.751x0.75(black)7/0.37-2.7/3.216
BRAIL A1-H-1G1.151x1.15(black)16/0.30-2.9/3.621
Type A2(with sheath)
BRAIL A2-3GH-1G0.751x0.757/0.370.74.0/5.030
BRAIL A2-3GH-1G1.151x1.1516/0.300.74.3/5.335
Type A3(with sheath)
BRAIL A3-3GH-2G0.752x0.757/0.370.96.7/8.867
BRAIL A3-3GH-4G0.754x0.757/0.371.08.0/10.4108
BRAIL A3-3GH-6G0.756x0.757/0.371.19.7/12.5160
BRAIL A3-3GH-10G0.7510x0.757/0.371.212.6/16.1259
BRAIL A3-3GH-14G0.7514x0.757/0.371.313.8/17.7495
BRAIL A3-3GH-36G0.7536x0.757/0.371.621.6/26.9752
BRAIL A3-3GH-48G0.7548x0.757/0.371.624.3/30.7963


KEY FEATURES

  • Three constructions distinguish unsheathed single-core, sheathed single-core and multicore wiring.

  • A1 and A2 sizes include 0.75 and 1.15 mm²; the A3 table lists 0.75 mm² cores.

  • Separate dimension rows support terminal, conduit and cable-entry selection.

SELECTION NOTES

Start with the wiring schedule: type, conductor size, core count and identification colour. Use the actual cable diameter when planning entries and bends. The listed radii are 6 times overall diameter for static installation and 15 times during handling. Include route protection and required railway acceptance documents with the enquiry.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

Which Type A cable has no outer sheath?

A1 is the unsheathed version. A2 and A3 have an LSZH outer sheath.

How do A2 and A3 differ?

A2 is a sheathed single core; A3 is the multicore construction.

Which conductor sizes are available?

A1 and A2 are listed in 0.75 and 1.15 mm². A3 is listed with 0.75 mm² cores in the listed core counts.

Is LSZH a circuit-integrity rating?

LSZH describes smoke and halogen characteristics. A requirement to maintain a circuit during fire needs its own specified test and supporting evidence.

What information helps identify the right order code?

Provide A1, A2 or A3, conductor size, number of cores, identification requirements and the required lengths.