Type C1 & C2 Railway Signalling Tail Cable, 2.5 mm² Class 5 Copper
Type C1 and C2 railway signalling tail cables with 2.5 mm2 class 5 tinned copper conductors, EPR insulation and an HDPCP sheath. The range includes single-core and multicore constructions.
TYPE C1 & C2 Railway Signalling Cable.pdf Contact us

APPLICATION

Type C1 and C2 cables provide signalling tails between equipment and railway location wiring. Both use 2.5 mm² class 5 tinned copper conductors with GP4 EPR insulation and an RS2 HDPCP outer sheath. C1 is the single-core version; C2 groups several cores within one sheath. The flexible conductor construction assists routing and termination at equipment, with bend limits still applying during installation.

STANDARD

  • NR/PS/SIG/00005(formerly RT/E/PS/00005)

CABLE CONSTRUCTION

  • Electrical Characteristics at 20℃Conductors: Tinned stranded copper, class 5 according to IEC 60228 & BS 6360.

  • Insulation: EPR Type GP4 to BS 7655.

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Sheath: HDPCP Type RS2 to BS 7655.

Nominal Conductor Cross Sectionmm2.5
Maximum DC Conductor ResistanceΩ/km8.21
Voltage RatingKV0.65/1.1
Nominal Insulation Thicknessmm1.05

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 6×OD (static); 15×OD (dynamic)

  • Temperature Range: -25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of cores& Nominal
Conductor Cross Sectional
Area
No.×mm
No. & Nominal
Diameter of Strands
No/mm
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
Type C1
BRAIL C1-3G5G-1G2.51×2.550/0.253.811.2/14.0195
Type C2
BRAIL C2-3G5G-2G2.52×2.550/0.253.814.9/18.8370
BRAIL C2-3G5G-4G2.54×2.550/0.253.816.4/20.9460
BRAIL C2-3G5G-7G2.57×2.550/0.253.818.7/23.7610
BRAIL C2-3G5G-10G2.510×2.550/0.253.822.5/28.6920
BRAIL C2-3G5G-12G2.512×2.550/0.253.823.2/29.3950
BRAIL C2-3G5G-16G2.516×2.550/0.253.825.3/32.01180

Routine test voltage: 2.5kV for 5 minutes


KEY FEATURES

  • 2.5 mm² class 5 conductors, with a listed strand construction of 50/0.25 mm.

  • Single-core C1 and C2 arrangements from 2 to 16 cores in the dimension table.

  • EPR insulation and HDPCP sheath, with a listed 0.65/1.1 kV voltage rating.

SELECTION NOTES

Match the core count to the equipment wiring diagram and select terminals suitable for fine-stranded conductors. Allow the listed 15 times overall-diameter radius while handling the cable and 6 times in its final static position. State any repeated movement, vibration or special environmental duty as a separate application requirement.

RELATED CABLE TYPES

FREQUENTLY ASKED QUESTIONS

What is the conductor size?

The C1 and C2 constructions on this page use 2.5 mm² conductors.

How do C1 and C2 differ?

C1 has one insulated conductor inside the sheath. C2 uses the multicore arrangements listed in the table.

Does class 5 mean continuous-flex service?

Class 5 identifies a flexible conductor construction. Repeated-motion service also requires a cable design and testing appropriate to that duty.

Is a screen included?

C1 and C2 are listed without a metallic screen. The related Type C3 construction adds an aluminium tape screen and drain wire.

What should be supplied for a quotation?

Provide the type, core count, route length, terminal arrangement and any project-specific acceptance or environmental requirements.