A-2Y2Yv S(H115)/S(H145)/S(H95)
APPLICATIONThe cables are designed for general uses in protective devises in railways signalling networks, and are suitable for installation in ducts.STANDARDDlk 1.013.107yDlk 1.013.108y (for 1.4/1.8mm conductor H95 type)Dlk 1.013.110yCABLE CONSTRUCTI…
A-2Y2Yv S(H115) S(H145) S(H95).pdf Contact us

APPLICATION

The cables are designed for general uses in protective devises in railways signalling networks, and are suitable for installation in ducts.

STANDARD

  • Dlk 1.013.107y

  • Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)

  • Dlk 1.013.110y

CABLE CONSTRUCTION

  • Type CodesConductors: Solid annealed copper, 0.9, 1.4 or 1.8 mm nominal diameter.

  • Insulation: Solid polyethylene.

  • Stranding: Single conductors are helically stranded in concentric layers. Cables from 14 conductors on, have two extra conductors with perforated insulation (surveillance conductors).

  • Core Wrapping: Plastic tape(s) with overlapping.

  • Inner Sheath: Low density polyethylene.

  • Outer Sheath: Low density polyethylene.

  • AJ- outdoor cable with protection against inductive infl uences

  • 2Y solid PE conductor insulation

  • 2Yv PE sheath with increased wall thickness

  • S signal cable

  • LG layer stranding

  • H (n) operating capacity

ELECTRICAL CHARACTERISTICS AT 20℃

Nominal Conductor Diametermm0.91.41.8
Maximum Conductor ResistanceΩ/km28.911.97.2
Minimum Insulation Resistance @500 V DC (1min)MΩ.km100001000010000
Maximum Conductor Capacitance @800Hz (AC)nF/km115145/95*145/95*
Dielectric Strength, conductor to conductor (DC voltage 1min)V353535353535
Surveillance Conductors



Loop resistance, maximumΩ/km190190190
Insulation resistance



- dry cable core, minimumMΩ.km100010001000
- wet cable core, maximumKΩ.km303030
Operating Voltage AC/DCV420/600420/600420/600
Test Voltage@50 Hz 1 min



Core to CoreVeff250025002500
Core to ScreenVeff250025002500

*The value“ 95” is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.

MECHANICAL AND THERMAL PROPERTIES

  • Minimum Bending Radius: 7.5×OD

  • Temperature Range: -40℃ to +60℃ (during operation); -10℃ to +60℃ (during installation)

DIMENSIONS AND WEIGHT

A-2Y2Yv n×1×0.9 S(H115)

Cable CodeNumber of
conductors
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
0.9mm Conductor, 1.55mm Insulated Wire
BR107y-2Y2Yv-2C0.9-S(H115)22.09.060
BR107y-2Y2Yv-4C0.9-S(H115)42.09.075
BR107y-2Y2Yv-7C0.9-S(H115)72.011.0100
BR107y-2Y2Yv-10C0.9-S(H115)102.012.0130
BR107y-2Y2Yv-14C0.9-S(H115)142.013.0170
BR107y-2Y2Yv-20C0.9-S(H115)202.014.0220
BR107y-2Y2Yv-24C0.9-S(H115)242.015.0260
BR107y-2Y2Yv-30C0.9-S(H115)302.216.0310
BR107y-2Y2Yv-40C0.9-S(H115)402.217.0380
BR107y-2Y2Yv-50C0.9-S(H115)502.219.0460
BR107y-2Y2Yv-60C0.9-S(H115)602.220.0540
BR107y-2Y2Yv-80C0.9-S(H115)802.222.0690
BR107y-2Y2Yv-100C0.9-S(H115)1002.225.0850
BR107y-2Y2Yv-120C0.9-S(H115)1202.226.0990
BR107y-2Y2Yv-140C0.9-S(H115)1402.228.01150
BR107y-2Y2Yv-160C0.9-S(H115)1602.229.01260
BR107y-2Y2Yv-180C0.9-S(H115)1802.232.01460
BR107y-2Y2Yv-200C0.9-S(H115)2002.232.01600

A-2Y2Yv n×1×1.4/1.8 S(H145)

Cable CodeNumber of
conductors
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1.4mm Conductor, 2.2mm Insulated Wire
BR107y-2Y2Yv-4C1.4-S(H145)42.011.0120
BR107y-2Y2Yv-7C1.4-S(H145)72.012.0180
BR107y-2Y2Yv-10C1.4-S(H145)102.015.0240
BR107y-2Y2Yv-14C1.4-S(H145)142.216.0320
BR107y-2Y2Yv-20C1.4-S(H145)202.217.0430
BR107y-2Y2Yv-24C1.4-S(H145)242.219.0500
BR107y-2Y2Yv-30C1.4-S(H145)302.220.0600
BR107y-2Y2Yv-40C1.4-S(H145)402.222.0770
BR107y-2Y2Yv-50C1.4-S(H145)502.224.0950
BR107y-2Y2Yv-60C1.4-S(H145)602.226.01120
BR107y-2Y2Yv-80C1.4-S(H145)802.229.01450
BR107y-2Y2Yv-100C1.4-S(H145)1002.233.01810
BR107y-2Y2Yv-120C1.4-S(H145)1202.235.02140
BR107y-2Y2Yv-140C1.4-S(H145)1402.237.02470
BR107y-2Y2Yv-160C1.4-S(H145)1602.239.02800
BR107y-2Y2Yv-180C1.4-S(H145)1802.242.03140
BR107y-2Y2Yv-200C1.4-S(H145)2002.243.03460

1.8mm Conductor, 2.7mm Insulated Wire

BR107y-2Y2Yv-4C1.8-S(H145)42.012.0170
BR107y-2Y2Yv-7C1.8-S(H145)72.014.0260
BR107y-2Y2Yv-10C1.8-S(H145)102.017.0355
BR107y-2Y2Yv-14C1.8-S(H145)142.218.0475
BR107y-2Y2Yv-20C1.8-S(H145)202.221.0655
BR107y-2Y2Yv-24C1.8-S(H145)242.222.0760
BR107y-2Y2Yv-30C1.8-S(H145)302.224.0930
BR107y-2Y2Yv-40C1.8-S(H145)402.227.01210
BR107y-2Y2Yv-50C1.8-S(H145)502.229.01480
BR107y-2Y2Yv-60C1.8-S(H145)602.231.01760
BR107y-2Y2Yv-80C1.8-S(H145)802.235.02310
BR107y-2Y2Yv-100C1.8-S(H145)1002.240.02860
BR107y-2Y2Yv-120C1.8-S(H145)1202.242.03390
BR107y-2Y2Yv-140C1.8-S(H145)1402.246.03930
BR107y-2Y2Yv-160C1.8-S(H145)1602.249.04500
BR107y-2Y2Yv-180C1.8-S(H145)1802.252.05100
BR107y-2Y2Yv-200C1.8-S(H145)2002.253.05600

A-2Y2Yv n×1×1.4/1.8 S(H95)

Cable CodeNumber of
conductors
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1.4mm Conductor, 2.7mm Insulated Wire
BR108y-2Y2Yv-10C1.4-S(H95)102.016.0270
BR108y-2Y2Yv-14C1.4-S(H95)142.018.0350
BR108y-2Y2Yv-20C1.4-S(H95)202.020.0470
BR108y-2Y2Yv-30C1.4-S(H95)302.224.0670
BR108y-2Y2Yv-50C1.4-S(H95)502.229.01050
1.8mm Conductor, 3.4mm Insulated Wire
BR108y-2Y2Yv-10C1.8-S(H95)102.019.0400
BR108y-2Y2Yv-14C1.8-S(H95)142.221.0540
BR108y-2Y2Yv-20C1.8-S(H95)202.224.0730
BR108y-2Y2Yv-30C1.8-S(H95)302.228.01050
BR108y-2Y2Yv-50C1.8-S(H95)502.236.01700