300/500V Mica+XLPE Insulated, LSZH Sheathed Power Cables to BS 7211 (Single Core)
APPLICATIONThe cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals and high-rise buildings.STANDARDSBasic design adapted from BS 7211:2012FIRE PERFORMANCECircuit Integ…
300_500V Mica+XLPE Insulated, LSZH Sheathed PowerCables to BS 7211 (Single Core).pdf Contact us

APPLICATION

The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals and high-rise buildings.

STANDARDS

Basic design adapted from BS 7211:2012

FIRE PERFORMANCE

Circuit IntegrityIEC 60331-21; BS 6387
Flame Retardance (Single vertical wire or cable test)IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)IEC 60332-3-24; EN 60332-3-24
Halogen freeIEC 60754-1; EN 50267-2-1
No Corrosive Gas EmissionIEC60754-2; EN 50267-2-2
Minimum Smoke EmissionIEC 61034-2; EN 61034-2

VOLTAGE RATING

300/500V

CABLE CONSTRUCTION

Conductor : Annealed copper conductor, solid according to BS EN 60228 class 1.

Fire Barrier : Mica glass tape.

Insulation : XLPE type GP 8 according to BS 7655-1.3. Crosslinked polyolefin material type EI 5 according to EN 50363-5 can be offered as option.

CPC (Circuit Protective Conductor) : Uninsulated copper conductor.

Outer Sheath : Extruded LSZH type LTS 2 according to BS 7655-6.1.

Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

COLOUR CODE

Insulation Colour : Brown or blue.

Sheath Colou r: White; other colours can be offered upon request.

PHYSICAL AND THERMAL PROPERTIES

Maximum temperature range during operation : 90°C

Maximum short circuit temperature (5 Seconds) : 250°C

Minimum bending radius : 4 x Overall Diameter

CONSTRUCTION PARAMETERS

ConductorFRP300-mRZ1-U
No. of Cores × Cross-sectional AreaConductor ClassNominal Insulation ThicknessCrosssectional Area of CPCClass of CPCNominal Sheath ThicknessMin. Overall DimensionsMax. Overall DimensionsApprox. Weight
No.×mm² mmmm² mmmmmmkg/km
1×1.010.701.010.95.1x6.26.0x7.366
1×1.510.701.010.95.4x6.46.3x7.674

ELECTRICAL PROPERTIES

Conductor operating temperature : 90°C

Ambient temperature : 30°C

CURRENT-CARRYING CAPACITIES (AMP) ACCORDING TO BS 7671:2008 TABLE 4E1A

Conductor cross-sectional areaRef. Method A (enclosed in conduit in thermally insulating wall etc.)Ref. Method B (enclosed in conduit on a wall or in trunking etc.)Ref. Method C (clipped direct)
2 cables, single-phase a.c. or d.c.3 or 4 cables, three-phase a.c.2 cables, single-phase a.c. or d.c3 or 4 cables, three-phase a.c.2 cables, single-phase a.c. or d.c. flat and touching3 or 4 cables, three-phase a.c. flat and touching or trefoil
1234567
mm²AAAAAA
1.0141317151917.5
1.5191723202523

VOLTAGE DROP (PER AMP PER METER) ACCORDING TO BS 7671:2008 TABLE 4E1B

Conductor cross-sectional area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, three-phase a.c.
Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)Ref. Methods A&B (enclosed in conduit or trunking)Ref. Methods C, F&G (clipped direct, on trays or in free air)
Cables touchingCables spaced*Cables touching, TrefoilCables touching, flatCables spaced*, flat
123456789
mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m
1.04646464640404040
1.53131313127272727

Note: *Spacings larger than one cable diameter will result in a large voltage drop.