whatsapp
backtop
600V-1000V XLPE Insulated Lead Sheathed Galvanized Steel Tape Armoured Cable to IEC 60502-1
600V-1000V XLPE insulated lead sheathedgalvanized steel tape armoured cableto IEC 60502-1.Suitable for low voltage power distribution,industrial plants, underground routes,cable trenches and harsh environments.
600V-1000V XLPE Insulated Galvanized Steel Tape Armored Cable with Lead Cover to IEC 60502-1.pdf Contact us

Applications

600V-1000V XLPE insulated lead sheathed

galvanized steel tape armoured cable

is designed for low voltage power distribution.


It is suitable for industrial plants,

substations, power networks,

oil and gas facilities

and infrastructure projects.


The XLPE insulation provides reliable

electrical performance and thermal stability.


The lead sheath provides additional protection

against moisture, chemicals

and hydrocarbons.


The galvanized steel tape armour provides

mechanical protection for fixed installation.


It is suitable for cable trenches,

cable ducts, underground routes

and protected outdoor installation.


This cable is commonly selected for

demanding industrial environments.


The cable should be selected according to

voltage rating, number of cores,

conductor size, lead sheath requirement,

armour type, installation method

and project specification.


Construction

Conductor : Solid or stranded copper

Insulation : XLPE

Core identification

1 Core : Red or Black

2 Cores : Red, Black

3 Cores : Red, Yellow, Blue

4 Cores : Red, Yellow, Blue, Black

5 Cores : Red, Yellow, Blue, Black, Green

Above 5 cores : Black core printed with white numbers

Inner sheath : PVC

Lead cover

Bedding : Paraffin-waxed crepe paper

Armor : Galvanized steel tapes or aluminum tapes for 1 core cable

Sheath : Special PVC. Color: black

Properties

Rated voltage : 600V/1000V

Fire retardance : IEC 60332-3-22

Operating temperature : -20~60°C

Max. conductor operating temperature : 90°C

Chemical resistance : Aliphatic and aromatic hydrocarbon resistance

No. of CoresConductor Corss-sectionConductor TypeDiameter over InsulationDiameter over Inner SheathDiameter over Lead SheathDiameter over ArmorMin. O.D.Max. O.D.Approx. Weight
mm²mmmmmmmmmmmmkg/km
125Stranded, Class 27.99.912.315.818.820.81003
135Stranded, Class 28.910.913.316.819.7921.81155
150Stranded, Class 210.212.214.618.121.0523.21341
170Stranded, Class 212.014.016.419.922.825.21639
195Stranded, Class 213.5515.618.021.524.3526.91966
1120Stranded, Class 215.2617.319.923.426.1928.92371
1150Stranded, Class 216.9719.021.625.127.8430.72736
1185Stranded, Class 219.0521.023.827.430.0733.23305
1240Stranded, Class 221.623.626.630.132.8836.34115
1300Stranded, Class 224.226.229.232.735.639.34882
1400Stranded, Class 227.730.133.336.839.7743.96108
1500Stranded, Class 231.433.837.240.743.9448.57570
1630Stranded, Class 236.238.642.245.748.9854.09461
21.5Solid, Class 12.797.910.312.415.5217.1701
21.5Stranded, Class 22.98.210.612.715.8117.4727
22.5Solid, Class 13.158.611.013.116.217.9773
22.5Stranded, Class 23.319.111.513.616.6818.4813
24Solid, Class 13.619.511.914.017.0718.8871
24Stranded, Class 23.8310.212.614.717.7519.6928
26Stranded, Class 24.3511.013.415.518.5320.41022
210Stranded, Class 25.2512.815.217.320.2722.41234
216Stranded, Class 26.2514.817.219.322.2124.51508
225Stranded, Class 27.918.120.522.625.4128.01980
235Stranded, Class 28.920.122.524.627.3530.22341
250Stranded, Class 210.222.825.427.530.1733.32924
270Stranded, Class 212.026.429.231.334.2437.83809
295Stranded, Class 213.5529.932.936.439.3843.45202
2120Stranded, Class 215.2633.336.540.043.0747.56258
2150Stranded, Class 216.9736.740.143.747.0451.97450
2185Stranded, Class 219.0541.344.948.451.857.19051
2240Stranded, Class 221.646.450.453.957.5263.411373
2300Stranded, Class 224.252.056.259.763.5470.113803
31.5Solid, Class 12.798.310.712.916.017.7745
31.5Stranded, Class 22.98.711.113.216.318.0772
32.5Solid, Class 13.159.111.513.616.6818.4826
32.5Stranded, Class 23.319.612.014.217.2719.0870
34Solid, Class 13.6110.112.514.617.6519.5942
34Stranded, Class 23.8310.813.215.418.4320.31003
36Stranded, Class 24.3511.714.116.219.2121.21111
310Stranded, Class 25.2513.616.018.221.1523.31369
316Stranded, Class 26.2515.818.220.323.1825.61700
325Stranded, Class 27.919.421.823.926.6829.42263
335Stranded, Class 28.921.524.126.228.9131.92800
350Stranded, Class 210.224.427.229.432.235.53528
370Stranded, Class 212.028.731.733.836.6740.44658
395Stranded, Class 213.5532.135.338.841.946.26288
3120Stranded, Class 215.2635.839.242.745.8850.67585
3150Stranded, Class 216.9739.943.547.050.4455.69123
3185Stranded, Class 219.0544.448.251.755.1960.911013
3240Stranded, Class 221.650.354.558.061.6968.013976
3300Stranded, Class 224.255.960.363.867.7174.716888
41.5Solid, Class 12.799.011.413.616.6818.4809
41.5Stranded, Class 22.99.411.814.017.0718.8841
42.5Solid, Class 13.159.912.314.417.4619.3906
42.5Stranded, Class 23.3110.512.915.118.1420.0950
44Solid, Class 13.6111.013.415.618.6220.51041
44Stranded, Class 23.8311.914.316.419.421.41103
46Stranded, Class 24.3512.815.217.420.3722.51242
410Stranded, Class 25.2515.017.419.522.4124.71558
416Stranded, Class 26.2517.419.822.024.8327.41972
425Stranded, Class 27.921.424.026.128.8131.82734
435Stranded, Class 28.923.926.528.731.5234.83326
450Stranded, Class 210.227.130.132.235.1138.74301
470Stranded, Class 212.031.835.038.641.7146.06120
495Stranded, Class 213.5535.639.042.545.6950.47656
4120Stranded, Class 215.2640.143.747.350.7356.09364
4150Stranded, Class 216.9744.348.151.655.2961.011181
4185Stranded, Class 219.0549.353.557.060.7267.013707
4240Stranded, Class 221.655.960.564.067.974.917374
4300Stranded, Class 224.262.267.070.574.5982.321002
51.5Solid, Class 12.799.812.214.417.4619.3885
51.5Stranded, Class 22.910.312.714.817.8519.7915
52.5Solid, Class 13.1510.813.215.318.3320.2993
52.5Stranded, Class 23.3111.513.916.019.0121.01045
54Solid, Class 13.6112.114.416.619.5921.61152
54Stranded, Class 23.8313.015.417.520.4722.61227
56Stranded, Class 24.3514.016.418.621.5323.81394
510Stranded, Class 25.2516.518.921.023.8626.31761
516Stranded, Class 26.2519.221.623.726.4829.22247
525Stranded, Class 27.923.726.328.531.1434.43159
535Stranded, Class 28.926.429.231.434.3437.93988
550Stranded, Class 210.230.333.336.939.8744.05479
570Stranded, Class 212.035.238.642.145.350.07287
595Stranded, Class 213.5539.843.446.950.3455.59228
5120Stranded, Class 215.2644.448.251.755.1960.911133
5150Stranded, Class 216.9749.053.256.760.4366.713475
5185Stranded, Class 219.0555.059.463.066.9373.816409
5240Stranded, Class 221.661.966.770.274.582.220691
5300Stranded, Class 224.269.374.578.182.5591.125436
71.5Stranded, Class 22.910.813.215.418.4320.3979
72.5Stranded, Class 23.3112.214.616.719.6921.71123
101.5Stranded, Class 22.913.916.318.421.3423.51245
102.5Stranded, Class 23.3115.718.120.223.0925.51464
121.5Stranded, Class 22.914.416.818.921.8224.11302
122.5Stranded, Class 23.3116.218.620.723.5726.01538
141.5Stranded, Class 22.915.117.519.622.524.81386
142.5Stranded, Class 23.3117.119.521.624.4427.01657
191.5Stranded, Class 22.916.819.221.324.1526.61598
192.5Stranded, Class 23.3119.121.523.626.3829.11935
241.5Stranded, Class 22.919.822.224.327.0629.91914
242.5Stranded, Class 23.3122.525.127.229.8833.02419
271.5Stranded, Class 22.920.222.624.727.4530.31995
272.5Stranded, Class 23.3123.025.627.730.3633.52534
301.5Stranded, Class 22.921.023.625.728.4231.42217
302.5Stranded, Class 23.3123.926.528.631.4334.72728
371.5Stranded, Class 22.922.825.427.530.1733.32463
372.5Stranded, Class 23.3125.928.730.833.5637.03152

KEY FEATURES


- Designed according to IEC 60502-1 requirements

- 600V-1000V voltage rating

- XLPE insulated conductors

- Lead sheath / lead cover protection

- Galvanized steel tape armoured construction

- Suitable for low voltage power distribution

- Suitable for industrial installations

- Suitable for cable trenches and ducts

- Suitable for harsh environments

- Provides mechanical and environmental protection



SELECTION NOTES


Before quotation, please confirm:


- Voltage rating

- Number of cores

- Conductor size

- Conductor material

- Lead sheath requirement

- Armour type

- Cable length

- Sheath colour

- Installation method

- Installation environment

- Required standard or project specification

- Packing requirement

- Destination port or delivery address


600V-1000V XLPE lead sheathed

galvanized steel tape armoured cable

is commonly selected for industrial projects.


It is suitable where mechanical protection,

moisture resistance and chemical resistance

are required.



RELATED CABLE TYPES


- IEC 60502 low voltage cable

- XLPE insulated power cable

- Lead sheathed power cable

- Galvanized steel tape armoured cable

- GSTA cable

- Steel wire armoured cable

- XLPE PVC armoured cable

- Low voltage armoured cable

- Underground power cable

- Industrial power cable



FAQ


What is this cable used for?


It is used for low voltage

power distribution.


It is suitable for industrial plants,

substations, cable trenches

and underground cable routes.



What standard does this cable follow?


This cable is designed according to

IEC 60502-1 requirements.



What is the function of the lead sheath?


The lead sheath provides additional

environmental protection.


It helps protect the cable against moisture,

chemicals and hydrocarbons.



Is this cable armoured?


Yes. This cable has galvanized

steel tape armour.


The armour provides mechanical protection

for fixed installation.



What is the difference between steel tape

armour and steel wire armour?


Steel tape armour provides mechanical

protection for fixed cable routes.


Steel wire armour is commonly used where

higher tensile protection is required.



Can this cable be used underground?


Yes. It can be used for underground

cable routes and cable trenches.


The final installation should follow

project specifications and local

installation requirements.



Where is lead sheathed cable commonly used?


It is commonly used in harsh environments.


Typical areas include industrial plants,

oil and gas facilities, substations

and infrastructure projects.



What information is required for quotation?


Please confirm voltage rating,

number of cores, conductor size,

lead sheath requirement and cable length.


Armour type, installation method

and destination port are also required.



Can BURYCABLE supply IEC 60502

lead sheathed GSTA cable?


Yes. BURYCABLE can supply IEC 60502-1

XLPE insulated lead sheathed

galvanized steel tape armoured cables.


We can support different conductor sizes,

core numbers, armour types,

lengths and packing requirements.