ZPGU Local Signalling Cables (Ordinary Non-Electrified Lines)
APPLICATIONSThe cables are designed for internal connection inside cabling of equipment shelters along the trackside. The shielded cables are suitable for local circuits.STANDARDSSNCF CT 445NF F 55-698CONSTRUCTIONConductors : Class 1 solid copper, 1.0…
ZPGU Local Signalling Cables(Ordinary Non-Electrified Lines).pdf Contact us

APPLICATIONS

The cables are designed for internal connection inside cabling of equipment shelters along the trackside. The shielded cables are suitable for local circuits.

STANDARDS

SNCF CT 445

NF F 55-698

CONSTRUCTION

Conductors : Class 1 solid copper, 1.0 mm² nominal cross section area.

Insulation : Solid polyethylene.

Cabling Element : Each two conductors are twisted together to form a pair.

Inner Sheath : PE.

Screen : Aluminium/Polyethylene tape screen.

Drain Wire : Tinned copper drain wire.

Outer Sheath : PVC/LSZH.

ELECTRICAL CHARACTERISTICS AT 20℃

Nominal Conductor Diametermm1.13
Nominal Cross Section Areamm²1.0
Maximum Conductor Resistance (DC)Ω/km18.1
Maximum Mutual Capacitance @1000Hz (AC)nF/km55
Operating VoltageV750

MECHANICAL AND THERMAL PROPERTIES

Minimum Bending Radius : 8×OD (static) ; 16×OD (dynamic)

Temperature Range : -40℃ to +70℃ (during operation) ; -20℃ to +50℃ (during installation)

DIMENSIONS AND WEIGHT

Cable CodeNo. of PairsNominal Sheath ThicknessNominal Overall DiameterNominal Weight
InnerOuter
  mmmmmmkg/km
1.13mm Conductor, 2.3 Insulated Wire
BRAIL ZPGU-2Y2Y(L)Y-1P1S11.01.59.895
BRAIL ZPGU-2Y2Y(L)Y-2P1S21.01.510.6130
BRAIL ZPGU-2Y2Y(L)Y-3P1S31.01.513.2179
BRAIL ZPGU-2Y2Y(L)Y-7P1S71.01.718.3301
BRAIL ZPGU-2Y2Y(L)Y-14P1S141.21.821.3532